Comparison of the Baska® mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

被引:27
作者
Alexiev, V. [1 ,2 ]
Ochana, A. [1 ,2 ]
Abdelrahman, D. [1 ,2 ]
Coyne, J. [1 ,2 ]
McDonnell, J. G. [1 ,2 ]
O'Toole, D. P. [1 ,2 ]
Neligan, P. [1 ,2 ]
Laffey, J. G. [3 ,4 ]
机构
[1] Galway Univ Hosp, Dept Anaesthesia, Galway, Ireland
[2] Natl Univ Ireland, Galway, Ireland
[3] St Michaels Hosp, Dept Anesthesia, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Toronto, ON, Canada
关键词
CERVICAL-SPINE IMMOBILIZATION; ANESTHETIZED ADULT PATIENTS; SUPRAGLOTTIC AIRWAY; TRACHEAL INTUBATION; I-GEL; MACINTOSH LARYNGOSCOPES; TRIAL; AIRWAYSCOPE(R); AIRTRAQ(R); MANAGEMENT;
D O I
10.1111/anae.12356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We compared the Baska((R)) mask with the single-use classic laryngeal mask airway (cLMA) in 150 females at low risk for difficult tracheal intubation in a randomised, controlled clinical trial. We found that median (IQR [range]) seal pressure was significantly higher with the Baska mask compared with the cLMA (40 (34-40 [16-40]) vs 22 (18-25 [14-40])cmH(2)O, respectively, p<0.001), indicating a better seal. In contrast, the first time success rate for insertion of the Baska mask was lower than that seen with the cLMA (52/71 (73%) vs 77/99 (98%), respectively, p<0.001). There were no differences in overall device insertion success rates (78/79 (99%) vs 68/71 (96%), respectively, p=0.54). The Baska mask proved more difficult to insert, requiring more insertion attempts, taking longer to insert and had higher median (IQR [range]) insertion difficulty scores (1.6 (0.8-2.2 [0.1-5.6]) vs 0.5 (0.3-1.4 [0.1-4.0]), respectively, p<0.001). There was also an increased rate of minor blood staining of the Baska mask after removal, but there were no differences in other complication rates, such as laryngospasm, or in the severity of throat discomfort. In conclusion, in clinical situations where the seal with the glottic aperture takes priority over ease of insertion, the Baska mask may provide a useful alternative to the cLMA.
引用
收藏
页码:1026 / 1032
页数:7
相关论文
共 13 条
[1]   An observational study of the Baska® mask: a novel supraglottic airway [J].
Alexiev, V. ;
Salim, A. ;
Kevin, L. G. ;
Laffey, J. G. .
ANAESTHESIA, 2012, 67 (06) :640-645
[2]   A comparison of the laryngeal mask airway and cuffed oropharyngeal airway in anesthetized adult patients [J].
Brimacombe, JR ;
Brimacombe, JC ;
Berry, AM ;
Morris, R ;
Mecklem, D ;
Clarke, G ;
Barry, J ;
Kirk, T .
ANESTHESIA AND ANALGESIA, 1998, 87 (01) :147-152
[3]   A comparison of the i-gel™ with the LMA-Unique™ in non-paralysed anaesthetised adult patients [J].
Francksen, H. ;
Renner, J. ;
Hanss, R. ;
Scholz, J. ;
Doerges, V. ;
Bein, B. .
ANAESTHESIA, 2009, 64 (10) :1118-1124
[4]   A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway [J].
Janakiraman, C. ;
Chethan, D. B. ;
Wilkes, A. R. ;
Stacey, M. R. ;
Goodwin, N. .
ANAESTHESIA, 2009, 64 (06) :674-678
[5]   Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway [J].
Keller, C ;
Pühringer, F ;
Brimacombe, JR .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (02) :186-187
[6]   Evaluation of the Airtraq® and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation [J].
Maharaj, C. H. ;
Costello, J. F. ;
Harte, B. H. ;
Laffey, J. G. .
ANAESTHESIA, 2008, 63 (02) :182-188
[7]   A comparison of tracheal intubation using the Airtraq® or the Macintosh laryngoscope in routine airway management:: a randomised, controlled clinical trial [J].
Maharaj, C. H. ;
O'Croinin, D. ;
Curley, G. ;
Harte, B. H. ;
Laffey, J. G. .
ANAESTHESIA, 2006, 61 (11) :1093-1099
[8]   Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization [J].
Malik, M. A. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (05) :723-730
[9]   Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope®, LMA CTrach®, and the Macintosh laryngoscopes [J].
Malik, M. A. ;
Subramaniam, R. ;
Churasia, S. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (05) :654-661
[10]   Determination of the optimal stylet strategy for the C-MAC® videolaryngoscope [J].
McElwain, J. ;
Malik, M. A. ;
Harte, B. H. ;
Flynn, N. H. ;
Laffey, J. G. .
ANAESTHESIA, 2010, 65 (04) :369-378