Evaluation of Transformer Insulation by Frequency Domain Technique

被引:6
|
作者
Poovamma, P. K. [1 ]
Sudhindra, A. [1 ]
Mallikarjunappa, K. [1 ]
Ahamad, T. R. Afzal [1 ]
机构
[1] Cent Power Res Inst, Bangalore, Karnataka, India
来源
2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2 | 2007年
关键词
D O I
10.1109/ICSD.2007.4290905
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurements of Dielectric Response in Frequency domain is being employed for assessing the condition of the paper-oil insulation system in Transformers. The laboratory measurements were carried out on Models based on simple Transformer insulation system. The dependence of frequency, temperature, voltage and ageing of the insulation system on the spectral behaviour of dielectric responses are discussed. The paper also present: correlation and comparison of the laboratory results, to the measurements performed on in-service Power Transformers. The healthiness of the insulation system of the in-service Transformers were evaluated arc recommendations were made to improve the condition of the insulation system to extend the service life of the Transformers.
引用
收藏
页码:681 / 684
页数:4
相关论文
共 50 条
  • [41] Experimental Investigation of Insulation Parameters Affecting Power Transformer Condition Assessment using Frequency Domain Spectroscopy
    Pradhan, M. K.
    Yew, K. J. H.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1851 - 1859
  • [42] Aging evaluation and moisture prediction of oil-immersed cellulose insulation in field transformer using frequency domain spectroscopy and aging kinetics model
    Liu, Jiefeng
    Fan, Xianhao
    Zhang, Yiyi
    Zhang, Chaohai
    Wang, Zixiao
    CELLULOSE, 2020, 27 (12) : 7175 - 7189
  • [43] Aging evaluation and moisture prediction of oil-immersed cellulose insulation in field transformer using frequency domain spectroscopy and aging kinetics model
    Jiefeng Liu
    Xianhao Fan
    Yiyi Zhang
    Chaohai Zhang
    Zixiao Wang
    Cellulose, 2020, 27 : 7175 - 7189
  • [44] Extraction of dielectric parameters and status evaluation of stator main insulation in frequency domain
    Liu J.
    Han Y.-Z.
    Zhao L.-S.
    Kong X.-Q.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (01): : 32 - 38
  • [45] Synthetic evaluation of solid insulation for power transformer
    Qian, Zheng
    Shang, Yong
    Yang, Li
    Yan, Zhang
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2000, 34 (04): : 5 - 9
  • [46] Insulation Design on High-Frequency Transformer for Solid-State Transformer
    Li, Zheqing
    Hsieh, Yi-Hsun
    Li, Qiang
    Lee, Fred C.
    Zhao, Chunyang
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 1149 - 1155
  • [47] A novel frequency domain based technique to detect transformer inter-turn faults
    Nandi, Subhasis
    IEEE IEMDC 2007: Proceedings of the International Electric Machines and Drives Conference, Vols 1 and 2, 2007, : 569 - 574
  • [48] A Modified Aging Kinetics Model for Aging Condition Prediction of Transformer Polymer Insulation by Employing the Frequency Domain Spectroscopy
    Liu, Jiefeng
    Fan, Xianhao
    Zhang, Yiyi
    Zheng, Hanbo
    Wang, Zixiao
    Zhao, Xixi
    POLYMERS, 2019, 11 (12)
  • [49] Experimental investigation and XY model simulation on the frequency domain spectroscopy characteristics of transformer oil-paper insulation
    Wen, Hua
    Ma, Zhiqin
    Wang, Yaolong
    Zhao, Xianping
    Liao, Ruijin
    Hao, Jian
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (08): : 1956 - 1964
  • [50] Time Domain Spectroscopy Measurements for the Insulation Diagnosis of a Current Transformer
    Kumar, Anuradha
    Mahajan, Satish M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1803 - 1811