DEVELOPMENT OF AN ION MOBILITY SPECTROMETER FOR DETECTION OF EXPLOSIVES

被引:8
作者
Sivakumar, N. [1 ]
Joseph, M. [1 ]
Manoravi, P. [1 ]
Rao, P. R. Vasudeva [1 ]
Raj, Baldev [2 ]
机构
[1] Indira Gandhi Ctr Atom Res, Chem Grp, Kalpakkam 603102, Tamil Nadu, India
[2] PSG Inst, Coimbatore, Tamil Nadu, India
关键词
explosives; ion mobility spectrometer; PETN; TDX; TNT; PRESSURE;
D O I
10.1080/10739149.2012.721109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion mobility spectrometer (IMS) is developed for use as an analytical tool and, in particular, for the detection of species used as explosives. From the initial design based on the literature, we have, through several optimization studies, reached a configuration that provides the desired sensitivity with adequate resolution. Results obtained with the optimized geometry are presented in this article. The sensitivity of the instrument is about 10ng for 2,4,6-trinitrotoluene (TNT) and Royal Demolition Explosive or cyclotrimethylene trinitramine (RDX) and about 50ng for pentaerythritol tetranitrate (PETN). These explosives are detected as clearly resolved features.
引用
收藏
页码:96 / 108
页数:13
相关论文
共 19 条
  • [1] [Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
  • [2] A review of recent, unconventional applications of ion mobility spectrometry (IMS)
    Armenta, Sergio
    Alcala, Manel
    Blanco, Marcelo
    [J]. ANALYTICA CHIMICA ACTA, 2011, 703 (02) : 114 - 123
  • [3] Note: Design and construction of a simple and reliable printed circuit board-substrate Bradbury-Nielsen gate for ion mobility spectrometry
    Du, Yongzhai
    Cang, Huaiwen
    Wang, Weiguo
    Han, Fenglei
    Chen, Chuang
    Li, Lin
    Hou, Keyong
    Li, Haiyang
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08)
  • [4] Analysis of a drift tube at ambient pressure: Models and precise measurements in ion mobility spectrometry
    Eiceman, GA
    Nazarov, EG
    Rodriguez, JE
    Stone, JA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (09) : 3610 - 3621
  • [5] A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds
    Ewing, RG
    Atkinson, DA
    Eiceman, GA
    Ewing, GJ
    [J]. TALANTA, 2001, 54 (03) : 515 - 529
  • [6] Mechanisms for negative reactant ion formation in an atmospheric pressure corona discharge
    Ewing, Robert G.
    Waltman, Melanie J.
    [J]. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (02) : 65 - 72
  • [7] FETTEROLF DD, 1993, J FORENSIC SCI, V38, P28
  • [8] Ion mobility spectrometry: Ion source development and applications in physical and biological sciences
    Guharay, Samar K.
    Dwivedi, Prabha
    Hill, Herbert H., Jr.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) : 1458 - 1470
  • [9] Koyuncu H, 2005, TURK J CHEM, V29, P255
  • [10] A study on the thermal decomposition behaviors of PETN, RDX, HNS and HMX
    Lee, JS
    Hsu, CK
    Chang, CL
    [J]. THERMOCHIMICA ACTA, 2002, 392 : 173 - 176