Influence of variability in the amount of inflow wastewater pollution concentration in small sewer system (case study)

被引:3
作者
Kurek, Karolina [1 ]
Bugajski, Piotr [1 ]
Operacz, Agnieszka [1 ]
Sliz, Paulina [2 ]
Jozwiakowski, Krzysztof [3 ]
机构
[1] Univ Agr, Fac Environm Engn & Land Surveying, Dept Sanit Engn & Water Management, Al Mickiewicza 21, PL-31120 Krakow, Poland
[2] Krakow Univ Econ, Rakowicka 27, PL-31510 Krakow, Poland
[3] Univ Life Sci, Akad 13, PL-20033 Lublin, Poland
来源
FIRST INTERNATIONAL SCIENTIFIC CONFERENCE ON ECOLOGICAL AND ENVIRONMENTAL ENGINEERING 2018 | 2019年 / 86卷
关键词
ACTIVATED-SLUDGE; REMOVAL; SEWAGE; IMPACT; SIZE;
D O I
10.1051/e3sconf/20198600028
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
The aim of study was the analyze of the impact of hydraulic load on the changes in the concentration of pollution indicators in raw sewage in years 2009-2014 in the small wastewater treatment plant. Qualitative analysis for raw sewage was included three parameters: total suspension solid, BOD and COD. The characteristics relation between the concentration of pollution indicators in raw sewage (depend variable) from the hydraulic load(independent variable) was presented by the Pearson linear correlation. In the 6 year study period were collected 32 samples of raw wastewater. Based on the result of linear regression analysis, showed that along with the increasing amount of wastewater in the sewer decrease the concentration of pollutions in raw wastewater. For total suspension solid, increase by 1 m(3) of quantity of raw sewage inflowing to wastewater treatment plant, causes a decrease in the concentration of this indicator by 0,53 g.m(-3). For the both organic indicators (BOD and COD), the was found that an increase of 1 m(3) the amount of raw sewage inflowing to wastewater treatment plant, caused a decrease of 0,75 gO(2).m(-3) BOD value and 0,66 gO(2).m(-3) COD value in raw sewage.
引用
收藏
页数:5
相关论文
共 19 条
[1]  
Boguniewicz-Zablocka J., 2017, EC ENV STUDIES, V17, P1103, DOI [10.25167/ees.2017.44.29, DOI 10.25167/EES.2017.44.29]
[2]  
Bugajski P, 2016, ACTA SCI POL-FORM C, V15, P3, DOI [10.15576/asp.fc/2016.15.2.3, 10.15576/ASP.FC.2016.2.3]
[3]   Life Cycle Assessment of wastewater treatment systems for small communities: Activated sludge, constructed wetlands and high rate algal ponds [J].
Garfi, Marianna ;
Flores, Laura ;
Ferrer, Ivet .
JOURNAL OF CLEANER PRODUCTION, 2017, 161 :211-219
[4]  
Heidrich Z., 2010, DOMESTIC SEWAGE TREA, P220
[5]   Optimal design and operation of activated sludge processes: State-of-the-art [J].
Hreiz, Rainier ;
Latifi, M. A. ;
Roche, Nicolas .
CHEMICAL ENGINEERING JOURNAL, 2015, 281 :900-920
[6]  
Jozwiakowski K., 2012, INFRASTR EKOL TER WI, V3, P73
[7]   Influence of the particle size of carbonate-siliceous rock on the efficiency of phosphorous removal from domestic wastewater [J].
Jozwiakowski, Krzysztof ;
Gajewska, Magdalena ;
Pytka, Aneta ;
Marzec, Michal ;
Gizinska-Gorna, Magdalena ;
Jucherski, Andrzej ;
Walczowski, Andrzej ;
Nastawny, Maria ;
Kaminska, Agnieszka ;
Baran, Stanislaw .
ECOLOGICAL ENGINEERING, 2017, 98 :290-296
[8]   Application of H2O2 to optimize ammonium removal from domestic wastewater [J].
Jozwiakowski, Krzysztof ;
Marzec, Michat ;
Fiedurek, Jan ;
Kaminska, Agnieszka ;
Gajewska, Magdalena ;
Wojciechowska, Ewa ;
Wu, Shubiao ;
Dach, Jacek ;
Marczuk, Andrzej ;
Kowlaczyk-Jusko, Alina .
SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 173 :357-363
[9]  
Kaczor G., 2012, INFRASTRUCT ECOL RUR, V3, P179
[10]  
Kaczor G, 2011, ACTA SCI POL-FORM C, V10, P27