An evaluation of B-mode and color Doppler ultrasonography for detecting periovulatory events in the bitch

被引:28
|
作者
Bergeron, Lindsay H. [1 ]
Nykamp, Stephanie G. [2 ]
Brisson, Brigitte A. [2 ]
Madan, Pavneesh [1 ]
Gartley, Cathy J. [3 ]
机构
[1] Univ Guelph, Ontario Vet Coll, Dept Biomed Sci, Guelph, ON N1G 2W1, Canada
[2] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Ontario Vet Coll, Dept Populat Med, Guelph, ON N1G 2W1, Canada
关键词
Canine; Ovulation; Ultrasound; Color Doppler; Preovulatory LH peak; IMAGE ATTRIBUTES; VAGINAL CYTOLOGY; OVULATION; TIME; PROGESTERONE; HORMONE; REPRODUCTION; APPEARANCE; FOLLICLES; BEHAVIOR;
D O I
10.1016/j.theriogenology.2012.08.016
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
When determining optimal breeding time in the bitch, specific periovulatory events must be identified. The main objectives were to relate ultrasonographic changes in ovarian blood flow, follicle/corpora lutea count and echotexture to periovulatory events, and to assess the efficacy of each for identifying these events. Twelve Beagle (N = 3), Beagle-cross (N = 2) and hound-cross (N = 7) bitches (body weight range, 7.5-27.5 kg) were examined daily from the onset of proestrus to approximately 4 days post-LH peak. Follicle and corpora lutea count and echotexture analyses were performed using B-mode ultrasound and ovarian blood flow analysis was performed using color Doppler ultrasound. Serum LH concentrations were analyzed by validated RIA. There was an increase (P < 0.05) in ovarian blood flow from the day of the preovulatory LH peak (605 pixels; confidence interval, 397856), to 1 day after this peak (1092 pixels; confidence interval, 72471535), enabling detection of the preovulatory LH peak. There were no significant changes in follicle/corpora lutea echotexture relative to days from the preovulatory LH peak. There were significant decreases in follicle/corpora lutea number between Days -1 and 3; Days -1 and 4; and Days 0 and 3, relative to the preovulatory LH peak. We concluded that color Doppler. ultrasound performed once daily was more accurate in identifying the preovulatory LH peak than B-mode ultrasound and enabled prospective determination of ovulation. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:274 / 283
页数:10
相关论文
共 50 条
  • [31] Method for detection of aspiration based on B-mode video ultrasonography
    Miura Y.
    Nakagami G.
    Yabunaka K.
    Tohara H.
    Murayama R.
    Noguchi H.
    Mori T.
    Sanada H.
    Radiological Physics and Technology, 2014, 7 (2) : 290 - 295
  • [32] A combined ultrasonic B-mode and color Doppler system for the classification of breast masses using neural network
    Xuejun Qian
    Bo Zhang
    Shaoqiang Liu
    Yueai Wang
    Xiaoqiong Chen
    Jingyuan Liu
    Yuzheng Yang
    Xiang Chen
    Yi Wei
    Qisen Xiao
    Jie Ma
    K. Kirk Shung
    Qifa Zhou
    Lifang Liu
    Zeyu Chen
    European Radiology, 2020, 30 : 3023 - 3033
  • [33] B-mode and M-mode Ultrasonography of Tongue Movements during Swallowing
    Galen, Steffi
    Jost-Brinkmann, Paul-Georg
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2010, 71 (02): : 125 - 135
  • [34] A combined ultrasonic B-mode and color Doppler system for the classification of breast masses using neural network
    Qian, Xuejun
    Zhang, Bo
    Liu, Shaoqiang
    Wang, Yueai
    Chen, Xiaoqiong
    Liu, Jingyuan
    Yang, Yuzheng
    Chen, Xiang
    Wei, Yi
    Xiao, Qisen
    Ma, Jie
    Shung, K. Kirk
    Zhou, Qifa
    Liu, Lifang
    Chen, Zeyu
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 3023 - 3033
  • [35] Color Doppler ultrasonography for treatment response prediction and evaluation in breast cancer
    Kumar, Anand
    Srivastava, Vivek
    Singh, Seema
    Shukla, Ram Chandra
    FUTURE ONCOLOGY, 2010, 6 (08) : 1265 - 1278
  • [36] Use of B-mode ultrasonography for fetal sex determination in dogs
    Gil, E. M. U.
    Garcia, D. A. A.
    Giannico, A. T.
    Froes, T. R.
    THERIOGENOLOGY, 2015, 84 (06) : 875 - 879
  • [37] Color Doppler Ultrasonography for the Evaluation of Subclavian Artery Stenosis
    Zhang, Jie
    Wang, Lijuan
    Chen, Ying
    Wang, Sibo
    Xing, Yingqi
    Cui, Li
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [38] B-Mode and Contrast-Enhanced Ultrasonography Aspects of Benign and Malignant Superficial Neoplasms in Dogs: A Preliminary Study
    Hillaert, Amber
    Stock, Emmelie
    Duchateau, Luc
    de Rooster, Hilde
    Devriendt, Nausikaa
    Vanderperren, Katrien
    ANIMALS, 2022, 12 (20):
  • [39] Combined Doppler and B-mode sonography in carpal tunnel syndrome
    Joy, Vijayan
    Therimadasamy, A. K.
    Chan, Y. C.
    Wilder-Smith, E. P.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2011, 308 (1-2) : 16 - 20
  • [40] Blood flow in its context:: Combining 3D B-mode and color doppler ultrasonic dat
    Petersch, Bernhard
    Hoenigmann, Dieter
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2007, 13 (04) : 748 - 757