Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms

被引:13
作者
Aguilar-Salinas, Pedro [1 ]
Brasiliense, Leonardo B. C. [2 ]
Gonsales, Douglas [1 ]
Mitchell, Bartley [1 ]
Lima, Andrey [1 ]
Sauvageau, Eric [1 ]
Hanel, Ricardo [1 ]
机构
[1] Baptist Hlth, Lyerly Neurosurg, 800 Prudential Dr,Tower B,11th Floor, Jacksonville, FL 32258 USA
[2] Univ Arizona, Div Neurosurg, Tucson, AZ 85721 USA
关键词
Intracranial aneurysms; unruptured aneurysms; endovascular treatment; flow diversion; pipeline flex embolization device; FLOW-DIVERTOR STENT; SINGLE-CENTER EXPERIENCE; INTRACRANIAL BIFURCATION ANEURYSMS; REDIRECTION ENDOLUMINAL DEVICE; INTERNAL CAROTID-ARTERY; WIDE-NECKED ANEURYSMS; EMBOLIZATION DEVICE; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; INITIAL-EXPERIENCE;
D O I
10.1080/17434440.2016.1231573
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficult task that often led to complex maneuvers. The Pipeline Flex Embolization Device (PED Flex) is the second generation and its introduction has arrived with high expectations due to a completely redesigned delivery system that intends to overcome deployment difficulties seen in the previous generation.Areas covered: Preclinical studies, mechanism of action of flow-diverters, technical aspects and deployment system of the PED Flex, and clinical outcomes with both PED generations.Expert commentary: Flow diversion has allowed us to treat lesions that would be otherwise challenging for surgical clipping or unsuitable for other endosaccular strategies. Although the experience with PED Flex is limited, initial results suggest its safety and short-term efficacy.
引用
收藏
页码:885 / 897
页数:13
相关论文
共 108 条
[11]   Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Ugga, Lorenzo ;
Marseglia, Mariano ;
Solari, Domenico ;
Caranci, Ferdinando ;
Mariniello, Giuseppe ;
Maiuri, Francesco ;
Cappabianca, Paolo .
ACTA NEUROCHIRURGICA, 2016, 158 (09) :1745-1755
[12]   p64 Flow Modulation Device in the treatment of intracranial aneurysms: initial experience and technical aspects [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Marseglia, Mariano ;
Cicala, Domenico ;
Caranci, Ferdinando ;
Maiuri, Francesco .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (02) :173-180
[13]   Flow diverter device for the treatment of small middle cerebral artery aneurysms [J].
Briganti, Francesco ;
Delehaye, Luigi ;
Leone, Giuseppe ;
Sicignano, Carmine ;
Buono, Giuseppe ;
Marseglia, Mariano ;
Caranci, Ferdinando ;
Tortora, Fabio ;
Maiuri, Francesco .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) :287-294
[14]   Risk Factors for Ischemic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the IntrePED Study [J].
Brinjikji, W. ;
Lanzino, G. ;
Cloft, H. J. ;
Siddiqui, A. H. ;
Boccardi, E. ;
Cekirge, S. ;
Fiorella, D. ;
Hanel, R. ;
Jabbour, P. ;
Levy, E. ;
Lopes, D. ;
Lylyk, P. ;
Szikora, I. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (09) :1673-1678
[15]   Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry [J].
Brinjikji, Waleed ;
Kallmes, David F. ;
Cloft, Harry J. ;
Lanzino, Giuseppe .
JOURNAL OF NEUROSURGERY, 2016, 124 (06) :1726-1730
[16]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[17]   Epidemiology and genetics of intracranial aneurysms [J].
Caranci, F. ;
Briganti, F. ;
Cirillo, L. ;
Leonardi, M. ;
Muto, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) :1598-1605
[18]   Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Scrivano, E. ;
Ceratto, R. ;
Lylyk, P. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :27-33
[19]   Spontaneous Delayed Migration/Shortening of the Pipeline Embolization Device: Report of 5 Cases [J].
Chalouhi, N. ;
Tjoumakaris, S. I. ;
Gonzalez, L. F. ;
Hasan, D. ;
Pema, P. J. ;
Gould, G. ;
Rosenwasser, R. H. ;
Jabbour, P. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (12) :2326-2330
[20]   Treatment of Ruptured Intracranial Aneurysms With the Pipeline Embolization Device [J].
Chalouhi, Nohra ;
Zanaty, Mario ;
Whiting, Alex ;
Tjoumakaris, Stavropoula ;
Hasan, David ;
Ajiboye, Norman ;
Hann, Shannon ;
Rosenwasser, Robert H. ;
Jabbour, Pascal .
NEUROSURGERY, 2015, 76 (02) :165-172