California's experience implementing a pilot newborn supplemental screening program using tandem mass spectrometry

被引:0
|
作者
Feuchtbaum, L
Lorey, F
Faulkner, L
Sherwin, J
Currier, R
Bhandal, A
Cunningham, G
机构
[1] Calif Dept Hlth Serv, Genet Dis Branch, Richmond, CA 94804 USA
[2] Calif Dept Hlth Serv, Genet Dis Lab, Richmond, CA 94804 USA
[3] Publ Hlth Inst, Berkeley, CA USA
关键词
newborn screening; tandem mass spectrometry; program implementation;
D O I
暂无
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE. In response to a California legislative mandate, a pilot tandem mass spectrometry (MS/MS) screening program was undertaken by the Genetic Disease Branch of the California Department of Health Services between January 2002 and June 2003. This article outlines the Genetic Disease Branch approach to implementing the MS/MS pilot program and the program evaluation strategies used. METHODS. Through the use of multiple data collection methods, we were able to describe hospital participation patterns, screening test uptake, screening test performance, follow-up services utilization, and provider and family satisfaction with the educational materials and follow-up services provided. RESULTS. During the 18-month pilot program, just more than one half of California's 755 698 newborns were offered MS/MS screening; among this group, 90% of parents chose to have their newborns screened. Fifty-one newborns were identified with MS/MS-detectable disorders, among 461 patients referred for follow-up testing (0.13% of the screened population). One disorder was diagnosed successfully for every 6939 newborns screened and for every 9 infants referred ( excluding phenylketonuria). The overall California population prevalence of MS/MS-detectable disorders was 1 case per 6500 infants ( excluding phenylketonuria). The positive predictive value for medium-chain acyl-CoA dehydrogenase deficiency was 86.7%, whereas the positive predictive value for short-chain acyl-CoA dehydrogenase deficiency was 21.6%. For a sample from Hawaii, 1 isovaleric aciduria case was detected among 6132 newborns. CONCLUSIONS. Evaluation of the California MS/MS screening pilot program demonstrated that this technology was effective in identifying additional metabolic disorders. The positive predictive value of screening was particularly good for medium-chain acyl-CoA dehydrogenase deficiency. Overall, patient referral rates were very acceptable. The utility of the program was also demonstrated by positive reviews from patients and providers.
引用
收藏
页码:S261 / S269
页数:9
相关论文
共 50 条
  • [31] The changing face of newborn screening: diagnosis of inborn errors of metabolism by tandem mass spectrometry
    Jones, PM
    Bennett, MJ
    CLINICA CHIMICA ACTA, 2002, 324 (1-2) : 121 - 128
  • [32] Identification of a frit-related sample carryover in newborn screening by tandem mass spectrometry
    Kim, Kyunghun
    Lee, Howon
    Lee, Jeong Joong
    Cha, Kyoungho
    Park, Nam Hyun
    Shin, Young Keun
    Chae, Hyojin
    Oh, Eun-Jee
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2023, 27 : 56 - 60
  • [33] Non-Ketotic Hyperglycinemia is usually not detectable by tandem mass spectrometry newborn screening
    Tan, E. S.
    Wiley, V.
    Carpenter, K.
    Wilcken, B.
    MOLECULAR GENETICS AND METABOLISM, 2007, 90 (04) : 446 - 448
  • [34] Evaluation of a New Tandem Mass Spectrometry Method for Sickle Cell Disease Newborn Screening
    Renoux, Celine
    Roland, Estelle
    Ruet, Severine
    Zouaghi, Sarah
    Michel, Marie
    Joly, Philippe
    Feray, Cecile
    Zhao, Fanny
    Gavanier, Deborah
    Gaucherand, Pascal
    Roumieu, Fanny
    Cannas, Giovanna
    Merazga, Salima
    Connes, Philippe
    Renom, Gilles
    Massardier, Jerome
    Cheillan, David
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2024, 10 (04)
  • [35] An Easily Overlooked Contamination of Syringes in Newborn Screening by Tandem Mass Spectrometry
    Wang, Yanyun
    Sun, Yun
    Jiang, Tao
    FRONTIERS IN PEDIATRICS, 2021, 8
  • [36] Newborn haemoglobinopathy screening using tandem mass spectrometry: Lessons from investigation of an unusual case
    Daniel, Yvonne
    Henthorn, Joan
    JOURNAL OF MEDICAL SCREENING, 2019, 26 (04) : 219 - 220
  • [37] Expanded newborn screening for inherited metabolic disorders by tandem mass spectrometry in a northern Chinese population
    Zhang, Hong
    Wang, Yanyun
    Qiu, Yali
    Zhang, Chao
    FRONTIERS IN GENETICS, 2022, 13
  • [38] Validation of the phenylalanine/tyrosine ratio determined by tandem mass spectrometry:: Sensitive newborn screening for phenylketonuria
    Ceglarek, U
    Müller, P
    Stach, B
    Bührdel, P
    Thiery, J
    Kiess, W
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (07) : 693 - 697
  • [39] Use of Tandem Mass Spectrometry for Newborn Screening of 6 Lysosomal Storage Disorders in a Korean Population
    Han, Minje
    Jun, Sun-Hee
    Song, Sang Hoon
    Park, Kyoung Un
    Kim, Jin Q.
    Song, Junghan
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2011, 31 (04): : 250 - 256
  • [40] Expanded newborn screening of inherited metabolic disorders by tandem mass spectrometry: Clinical and laboratory aspects
    Uttam, G
    Dasouki, M
    CLINICAL BIOCHEMISTRY, 2006, 39 (04) : 315 - 332