Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

被引:88
|
作者
Berk, Derya [1 ]
Gurkan, Yavuz [1 ]
Kus, Alparslan [1 ]
Ulugol, Halim [2 ]
Solak, Mine [1 ]
Toker, Kamil [1 ]
机构
[1] Kocaeli Univ, Kocaeli Univ Hosp, Fac Med, Dept Anesthesiol & Reanimat, Umuttepe, Kocaeli, Turkey
[2] Baskent Univ, Istanbul Hosp, Dept Anesthesiol & Reanimat, TR-06490 Ankara, Turkey
关键词
Radial artery cannulation; Ultrasound guidance; Long axis in-plane; Short axis out-of-plane; Complication; CATHETERS; GUIDANCE;
D O I
10.1007/s10877-013-9437-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Arterial cannulation with ultrasound (US) guidance increases the success rate and reduces complications. US-guided vascular access has two main approaches: long axis in-plane (LA-IP) and short axis out-of-plane (SA-OOP) approaches. The purpose of this study was to compare performance time and possible complications between two techniques. After obtaining ethics committee approval and informed patient consent, a prospective and randomized trial was conducted at ASA I-III, patients between the ages of 20-70 years. 108 patients were scheduled for radial arterial cannulaton in patients undergoing elective surgery under general anesthesia. Patients were divided into two groups as LA-IP and SA-OOP approaches with sealed envelope randomized method. After induction of anesthesia, the distance between skin-to-artery and the diameter of radial artery in US-imaging was recorded. The successful cannulation time, the number of attempts, potential complications such as thrombosis, edema, vasospasm, hematoma and posterior wall puncture were recorded. Demographic and hemodynamic parameters were similar in two groups. The diameter and the depth of artery were also similar in both of groups. Cannulation time was shorter in LA-IP Group compared to SA-OOP (24 +/- A 17 s vs. 47 +/- A 34 s respectively, p < 0.05). The arterial cannulation by LA-IP approach increased the rate of cannula-insertion success at the first attempt (76 %) compared to SA-OOP approach (51 %). Posterior wall damage during arterial cannulation were found in 30 patients with SA-OOP Group (56 %) and 11 patients with LA-IP Group (20 %), (p < 0.05). In our study, the use of LA-IP approach during US-guided radial artery cannulation has higher success rate at first insertion. We also found LA-IP approach results in shorter cannulation time and decreased the incidence of complications.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [31] Skin wheal facilitates ultrasound-guided out-of-plane radial artery cannulation in children
    Han, Ding
    Pan, Shoudong
    MINERVA ANESTESIOLOGICA, 2024, 90 (04) : 347 - 348
  • [32] A Crossover Study Comparing In-Plane and Out-of-Plane Approaches for Simulated Ultrasound-Guided Central Venous Cannulation on Phantom Models by Anaesthesiology Trainees
    Yap, K. B.
    Shereen, T. S. P.
    Yeoh, C. N.
    Liu, C. Y.
    Nadia, M. N.
    Joanna, O. S. M.
    Muhammad, M.
    MEDICINE AND HEALTH-KUALA LUMPUR, 2019, 14 (01): : 135 - 144
  • [33] Ultrasound-guided, long-axis, in-plane, infraclavicular axillary vein cannulation: A 6-year experience
    Kosinski, Sylweriusz
    Podsiadlo, Pawel
    Stachowicz, Jakub
    Mikiewicz, Maciej
    Serafinowicz, Zofia
    Lukasiewicz, Katarzyna
    Mendrala, Konrad
    Darocha, Tomasz
    JOURNAL OF VASCULAR ACCESS, 2023, 24 (04): : 754 - 761
  • [34] Syringe-Free, Long-Axis in-Plane Versus Short-Axis Classic out-of-Plane Approach for Ultrasound-Guided Internal Jugular Vein Catheter Placement in Critically Ill Children: A Prospective Randomized Study
    Keskin, Halil
    Keskin, Filiz
    Aydin, Pelin
    Guler, Muhammet Akif
    Ahiskalioglu, Ali
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (07) : 2094 - 2099
  • [35] Incidence of intraneural needle insertion in ultrasound-guided femoral nerve block: A comparison between the out-of-plane versus the in-plane approaches
    Ruiz, A.
    Sala-Blanch, X.
    Martinez-Ocon, J.
    Carretero, M. J.
    Sanchez-Etayo, G.
    Hadzic, A.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2014, 61 (02): : 73 - 77
  • [36] Long-Axis Versus Short-Axis View of Ultrasound-Guided Central Venous Cannulation
    Maheshwari, Praveen
    Maheshwari, Parul
    CRITICAL CARE MEDICINE, 2015, 43 (12) : E597 - E597
  • [37] Ultrasound guidance for internal jugular vein cannulation in neonates: Modified dynamic needle tip positioning short-axis out-of-plane technique versus long-axis in-plane technique, a randomized controlled trial
    Tan, Yanzhe
    Tu, Zhenzhen
    Ye, Ping
    Xu, Ying
    Ye, Mao
    Bai, Lin
    Liu, Lifei
    JOURNAL OF VASCULAR ACCESS, 2022, 23 (06): : 922 - 929
  • [38] Ultrasound-guided femoral catheter placement: a randomised comparison of the in-plane and out-of-plane techniques
    Fredrickson, M. J.
    Danesh-Clough, T. K.
    ANAESTHESIA, 2013, 68 (04) : 382 - 390
  • [39] Ultrasound-guided short-axis in-plane method for safe axillary vein catheterization
    Tang, Jia-Xi
    Wang, Ling
    Xu, Fang
    Nian, Wei-Qi
    Liu, Hong-Liang
    JOURNAL OF CLINICAL ANESTHESIA, 2022, 82
  • [40] Modified long-axis in-plane ultrasound technique versus conventional palpation technique for radial arterial cannulation A prospective randomized controlled trial
    Wang, Jiebo
    Lai, Zhongmeng
    Weng, Xianfeng
    Lin, Yong
    Wu, Guohua
    Su, Jiansheng
    Huang, Qijian
    Zeng, Jian
    Liu, Junle
    Zhao, Zisong
    Yan, Ting
    Zhang, Liangcheng
    Zhou, Linying
    MEDICINE, 2020, 99 (02)