Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

被引:91
作者
Berk, Derya [1 ]
Gurkan, Yavuz [1 ]
Kus, Alparslan [1 ]
Ulugol, Halim [2 ]
Solak, Mine [1 ]
Toker, Kamil [1 ]
机构
[1] Kocaeli Univ, Kocaeli Univ Hosp, Fac Med, Dept Anesthesiol & Reanimat, Umuttepe, Kocaeli, Turkey
[2] Baskent Univ, Istanbul Hosp, Dept Anesthesiol & Reanimat, TR-06490 Ankara, Turkey
关键词
Radial artery cannulation; Ultrasound guidance; Long axis in-plane; Short axis out-of-plane; Complication; CATHETERS; GUIDANCE;
D O I
10.1007/s10877-013-9437-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Arterial cannulation with ultrasound (US) guidance increases the success rate and reduces complications. US-guided vascular access has two main approaches: long axis in-plane (LA-IP) and short axis out-of-plane (SA-OOP) approaches. The purpose of this study was to compare performance time and possible complications between two techniques. After obtaining ethics committee approval and informed patient consent, a prospective and randomized trial was conducted at ASA I-III, patients between the ages of 20-70 years. 108 patients were scheduled for radial arterial cannulaton in patients undergoing elective surgery under general anesthesia. Patients were divided into two groups as LA-IP and SA-OOP approaches with sealed envelope randomized method. After induction of anesthesia, the distance between skin-to-artery and the diameter of radial artery in US-imaging was recorded. The successful cannulation time, the number of attempts, potential complications such as thrombosis, edema, vasospasm, hematoma and posterior wall puncture were recorded. Demographic and hemodynamic parameters were similar in two groups. The diameter and the depth of artery were also similar in both of groups. Cannulation time was shorter in LA-IP Group compared to SA-OOP (24 +/- A 17 s vs. 47 +/- A 34 s respectively, p < 0.05). The arterial cannulation by LA-IP approach increased the rate of cannula-insertion success at the first attempt (76 %) compared to SA-OOP approach (51 %). Posterior wall damage during arterial cannulation were found in 30 patients with SA-OOP Group (56 %) and 11 patients with LA-IP Group (20 %), (p < 0.05). In our study, the use of LA-IP approach during US-guided radial artery cannulation has higher success rate at first insertion. We also found LA-IP approach results in shorter cannulation time and decreased the incidence of complications.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 13 条
[1]   Short-axis versus long-axis approaches for teaching ultrasound-guided vascullar access on a new inanimate model [J].
Blaivas, M ;
Brannam, L ;
Fernandez, E .
ACADEMIC EMERGENCY MEDICINE, 2003, 10 (12) :1307-1311
[2]   Ultrasound guided radial artery cannulation: procedure description and literature review [J].
Carmona Monge, F. J. ;
Martinez Lareo, M. ;
Nunez Reiz, A. .
ENFERMERIA INTENSIVA, 2011, 22 (04) :144-149
[3]  
Chittoodan S, 2011, MED ULTRASON, V13, P21
[4]  
Edanaga Mitsutaka, 2012, Masui, V61, P221
[5]   Use of ultrasound guidance in the insertion of radial artery catheters [J].
Levin, PD ;
Sheinin, O ;
Gozal, Y .
CRITICAL CARE MEDICINE, 2003, 31 (02) :481-484
[6]   DELAYED ISCHEMIA OF THE HAND NECESSITATING AMPUTATION AFTER RADIAL ARTERY CANNULATION [J].
MANGAR, D ;
LABORDE, RS ;
VU, DN .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03) :247-250
[7]   Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department [J].
Miller, AH ;
Roth, BA ;
Mills, TJ ;
Woody, JR ;
Longmoor, CE ;
Foster, B .
ACADEMIC EMERGENCY MEDICINE, 2002, 9 (08) :800-805
[8]   Incidence of Posterior Vessel Wall Puncture During Ultrasound-guided Vessel Cannulation in a Simulated Model [J].
Moon, Cynthia H. ;
Blehar, David ;
Shear, Michael A. ;
Uyehara, Paradis ;
Gaspari, Romolo J. ;
Arnold, Jeremy ;
Cukor, Jeffrey .
ACADEMIC EMERGENCY MEDICINE, 2010, 17 (10) :1138-1141
[9]   The Effect of Catheter to Vein Ratio on Blood Flow Rates in a Simulated Model of Peripherally Inserted Central Venous Catheters [J].
Nifong, Thomas P. ;
McDevitt, Timothy J. .
CHEST, 2011, 140 (01) :48-53
[10]   Use of ultrasonography as a rescue technique for failed radial artery cannulation [J].
Sandhu, NS ;
Patel, B .
JOURNAL OF CLINICAL ANESTHESIA, 2006, 18 (02) :138-141