Estimation of the time elapsed between exposure and readout using peak ratios of LiF:Mg,Cu,P (MCP-N, GR200A)

被引:12
|
作者
Budzanowski, M
Vergara, JCS
Ryba, E
Bilski, P
Olko, P
Waligórski, MPR
机构
[1] Inst Nucl Phys, PL-31342 Krakow, Poland
[2] CIEMAT, E-28040 Madrid, Spain
[3] Ctr Oncol, PL-30115 Krakow, Poland
关键词
D O I
10.1093/oxfordjournals.rpd.a032822
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The applicability of peak area ratios (peak2/peak4 and peak3/peak4) in the glow curves of LiF:Mg,Cu,P for the estimation of time between exposure and readout, t(ER) was studied. MCP-N and GR-200 LiF:Mg,Cu,P detectors were exposed to simulate an 'accidental' dose at times before readout ranging from 24 h to 3 months. Two groups of detectors were exposed simultaneously to determine the fading of irradiated detectors and the sensitivity variations of stored, non-irradiated detectors. Peak areas were evaluated using a computerised glow curve analysis code. The peak 2/peak 4 ratio is well suited for evaluating t(ER) below 1 week, while the peak 3/peak 4 ratio serves for t(ER) up to 3 months. The method can be applied in personal and environmental dosimetry to evaluate the date of a high dose rate, accidental exposure.
引用
收藏
页码:149 / 152
页数:4
相关论文
共 40 条
  • [1] The fading of different peaks in LiF:Mg,Cu,P (MCP-N and GR-200A) TL detectors
    Budzanowski, M
    Saez-Vergara, JC
    Gomez-Ros, JM
    Romero-Guitierrez, AM
    Ryba, E
    RADIATION MEASUREMENTS, 1998, 29 (3-4) : 361 - 364
  • [2] Fading of different peaks in LiF:Mg,Cu,P (MCP-N and GR-200A) TL detectors
    Inst of Nuclear Physics, Krakow, Poland
    Radiat Meas, 3-4 (361-364):
  • [4] MCP-N (LiF:Mg,Cu,P) TLDs for radon measurements with charcoal canisters
    Bogacz, J
    Mazur, J
    Swakon, J
    Budzanowski, M
    Olko, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A267 - A270
  • [5] MCP-N (LiF:Mg,Cu,P) TLDs for radon measurements with charcoal canisters
    Bogacz, J
    Mazur, J
    Swakon, J
    Budzanowski, M
    Olko, P
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 267 - 270
  • [6] The influence of post-exposure heating on the stability of MCP-N (LiF:Mg,Cu,P) TL detectors
    Budzanowski, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A257 - A260
  • [7] The influence of post-exposure heating on the stability of MCP-N (LiF:Mg,Cu,P) TL detectors
    Budzanowski, M
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 257 - 260
  • [8] A kinetic model for the thermoluminescent high dose response of LiF:Mg,Cu,P (MCP-N)
    Benavente, J. F.
    Gomez-Ros, J. M.
    Correcher, V
    APPLIED RADIATION AND ISOTOPES, 2021, 170
  • [9] FIELD APPLICATION OF LIF-MG,CU,P (GR200A) AND LIF-MG,TI (TLD-100) THERMOLUMINESCENT MATERIALS IN ENVIRONMENTAL DOSIMETRY
    BRAI, M
    PUCCIO, P
    BARTOLOTTA, A
    FERRARA, G
    HAUSER, S
    RIZZO, S
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (02) : 107 - 111
  • [10] Dosimetric properties of TL foils based on LiF:Mg,Cu,P (MCP-N) phosphors for clinical applications
    Kisielewicz, K.
    Swiebocka, J.
    Czopyk, L.
    Klosowski, M.
    Lesiak, J.
    Byrski, E.
    Kabat, D.
    Wawrzak, M.
    Sladowska, A.
    Dziecichowicz, A.
    Olko, P.
    Waligorski, M. P. R.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 716 - 718