The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb

被引:27
作者
Moon, Hyun-Soo [1 ,2 ]
Choi, Chong-Hyuk [1 ,3 ]
Jung, Min [1 ,3 ]
Lee, Dae-Young [1 ,4 ]
Kim, Jung-Hwan [3 ]
Kim, Sung-Hwan [1 ,5 ]
机构
[1] Yonsei Univ, Arthroscopy & Joint Res Inst, Coll Med, Seoul, South Korea
[2] Hallym Univ, Coll Med, Dept Orthoped Surg, Sacred Heart Hosp, Anyang, South Korea
[3] Yonsei Univ, Severance Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[4] Saegil Hosp, Dept Orthoped Surg, Seoul, South Korea
[5] Yonsei Univ, Gangnam Severance Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
关键词
Knee joint rotation; Measurement accuracy; Coronal alignment of the lower limb; EOS image; HIGH TIBIAL OSTEOTOMY; WEIGHT-BEARING; LOWER-EXTREMITY; DEFORMITY;
D O I
10.1186/s12891-020-03487-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Although the measurement of coronal alignment of the lower limb on conventional full-length weight-bearing anteroposterior (FLWAP) radiographs was reported to be influenced by the knee joint rotation, no comparative analysis was performed considering the effects of knee joint rotation on the sagittal and axial planes simultaneously using the three-dimensional images while taking into account the actual weight-bearing conditions. The aim of this study was to investigate the effect of knee joint rotation on the measurement accuracy of coronal alignment of the lower limb on the FLWAP radiograph. Methods Radiographic images of 90 consecutive patients (180 lower limbs) who took both the FLWAP radiograph and the EOS image were retrospectively reviewed. The relationship among delta values of mechanical tibiofemoral angle (mTFA) between the FLWAP radiographs and the EOS images (Delta mTFA), knee flexion/extension angle (sagittal plane rotation) on the EOS images, and patellar rotation (axial plane rotation) on the FLWAP radiographs were analyzed. Further, subgroup analysis according to each direction of knee joint rotation was performed. Results There was a significant correlation between Delta mTFA and sagittal plane rotation (r = 0.368,P < 0.001), whereas axial plane rotation was not correlated. In the analysis according to the direction, statistically significant correlation was observed only in the knee flexion group (r = 0.399,P < 0.001). The regression analysis showed a significant linear relationship between Delta mTFA and sagittal plane rotation (r(2) = 0.136,P < 0.001). Additional subgroup analysis in patients with the patellar rotation greater than 3% showed a similar result of a linear relationship between Delta mTFA and sagittal plane rotation (r(2) = 0.257,P < 0.001), whereas no statistically significant relationship was found in patients with the patellar rotation less than 3%. Conclusion The measurement accuracy of coronal alignment of the lower limb on the FLWAP radiographs would be influenced by knee flexion, specifically when there is any subtle rotation of the knee joint in the axial plane. A strict patellar forward position without axial plane rotation of the knee could provide accurate results of the measurement even if there is a fixed flexion contracture of the knee.
引用
收藏
页数:9
相关论文
共 25 条
  • [11] Do small changes in rotation affect measurements of lower extremity limb alignment?
    Jamali, Amir A.
    Meehan, John P.
    Moroski, Nathan M.
    Anderson, Matthew J.
    Lamba, Ramit
    Parise, Carol
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [12] Coronal alignment of the lower limb
    Jenny, JY
    Boeri, C
    Ballonzoli, L
    [J]. ACTA ORTHOPAEDICA, 2005, 76 (03) : 403 - 407
  • [13] Navigated lower limb axis measurements:: Influence of mechanical weight-bearing simulation
    Kendoff, Daniel
    Board, Timothy N.
    Citak, Musa
    Gardner, Michael J.
    Hankemeier, Stefan
    Ostermeier, Sven
    Krettek, Christian
    Huefner, Tobias
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) : 553 - 561
  • [14] The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis
    Kim, Young-Hoo
    Park, Jang-Won
    Kim, Jun-Shik
    Park, Sang-Doo
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 379 - 385
  • [15] Underestimation of varus angulation in knees with flexion deformity
    Koshino, T
    Takeyama, M
    Jiang, LS
    Yoshida, T
    Saito, T
    [J]. KNEE, 2002, 9 (04) : 275 - 279
  • [16] Are Navigation Systems Accurate Enough to Predict the Correction Angle During High Tibial Osteotomy? Comparison of Navigation Systems With 3-Dimensional Computed Tomography and Standing Radiographs
    Kyung, Bong Soo
    Kim, Jae Gyoon
    Jang, Ki-Mo
    Chang, Minho
    Moon, Young-Wan
    Ahn, Jin Hwan
    Wang, Joon Ho
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (10) : 2368 - 2374
  • [17] The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy
    Lee, Dae-Hee
    Han, Seoung-Bum
    Oh, Kwang-Jun
    Lee, Jun Seop
    Kwon, Jae-Ho
    Kim, Jong-In
    Patnaik, Smarajit
    Shetty, Gautam M.
    Nha, Kyung-Wook
    [J]. KNEE, 2014, 21 (02) : 451 - 455
  • [18] Rotational deformity in varus osteoarthritis of the knee - Analysis with computed tomography
    Matsui, Y
    Kadoya, Y
    Uehara, K
    Kobayashi, A
    Takaoka, K
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 147 - 151
  • [19] EOS® biplanar X-ray imaging: concept, developments, benefits, and limitations
    Melhem, Elias
    Assi, Ayman
    El Rachkidi, Rami
    Ghanem, Ismat
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2016, 10 (01) : 1 - 14
  • [20] PALEY D, 1994, ORTHOP CLIN N AM, V25, P425