Straight and Offset Implant Placement under Axial and Nonaxial Loads in Implant-Supported Prostheses: Strain Gauge Analysis

被引:10
作者
Abreu, Celina Wanderley [1 ]
Nishioka, Renato Sussumu [2 ]
Balducci, Ivan [2 ]
Consani, Rafael Leonardo Xediek [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Prosthodont & Periodontol, Piracicaba, Brazil
[2] Sao Paulo State Univ, Dept Social Dent, Sao Jose Dos Campos, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2012年 / 21卷 / 07期
关键词
Strain gauge; Morse taper implant; axial load; ORAL IMPLANTS; BONE; CLINICIAN; FIXATION; DESIGN; FORCES; LAW;
D O I
10.1111/j.1532-849X.2012.00871.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
引用
收藏
页码:535 / 539
页数:5
相关论文
共 28 条
[1]  
Abreu CW, 2010, BRAZ J ORAL SCI, V9, P11
[2]   Analysis of load transfer and stress distribution by an implant-supported fixed partial denture [J].
Assif, D ;
Marshak, B ;
Horowitz, A .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (03) :285-291
[3]  
Bidez M W, 1992, J Oral Implantol, V18, P264
[4]  
Branemark P-I., 1987, TISSUE INTEGRATED PR, P129
[5]  
Carr A B, 1996, Int J Oral Maxillofac Implants, V11, P589
[6]  
Castilio Daniela, 2006, J. Appl. Oral Sci., V14, P77, DOI 10.1590/S1678-77572006000200003
[7]   Implant design and interface force transfer - A photoelastic and strain-gauge analysis [J].
Cehreli, M ;
Duyck, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :249-257
[8]  
Chao Y., 1988, CLIN MATER, V3, P309
[9]   The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study [J].
Duyck, J ;
Ronold, HJ ;
Van Oosterwyck, H ;
Naert, I ;
Sloten, JV ;
Ellingsen, JE .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (03) :207-218
[10]   Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses:: an in vivo study [J].
Duyck, J ;
Van Oosterwyck, H ;
Vander Sloten, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) :465-475