Investigation on the gas particle separation efficiency of the gas particle partitioner

被引:3
作者
Asbach, C
Kuhlbusch, TAJ
Fissan, H
机构
[1] Univ Duisberg Essen, D-47057 Duisburg, Germany
[2] Inst Energie & Umwelttech eV, D-47229 Duisburg, Germany
关键词
airborne particles; TEOM; artifact correction; electrostatic separation; corona; PM sampling;
D O I
10.1016/j.atmosenv.2005.08.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A gas particle partitioner (GPP, US patent 6,761,752 B2) that allows highly efficient separation of gas and particles with no effect on the thermodynamic conditions and substantially no change of the composition of the gas has been developed. The GPP is a coaxial arrangement with inner and outer electrode. It utilizes a corona discharge to electrically charge the particles and a strong electric field in a separate unit to take them out of the sample flow. Several measures were taken to minimize an effect of the corona discharge on the gas composition. The GPP is designed such that when switched on, the sample flow is particle free, whereas when switched off, the sample flow contains a representative sample of the aerosol. The GPP as described in this manuscript was designed to meet the requirements for precise artifact correction with particle mass concentration monitors, such as the TEOM. This paper focuses on the gas particle separation efficiency of the instrument. The separation efficiency was determined for both, (ultra-) fine and coarse particles. The (ultra-) fine particles were generated with diameters ranging from 18 to 255 nm of polystyrene latex particles and their size distributions measured with a scanning mobility particle sizer (SNIPS). Coarse particles with diameters between 4.5 and 10.7 mu m were generated from a sodium chloride solution and characterized with an aerodynamic particle sizer (APS) and a tapered element oscillating microbalance (TEOM). The investigations showed that the separation efficiency was very near 100% for all particles with diameters larger than 25 nm, whereas it decreased for smaller diameters. Particles of size 18 nm were separated from the gas flow with an efficiency of approximately 97%. Along with near 100% separation efficiency, the additional gas concentrations were 42 ppbV for O-3 and 15 ppbV for NO2. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7825 / 7835
页数:11
相关论文
共 13 条
[1]   Effect of corona discharge on the gas composition of the sample flow in a Gas Particle Partitioner [J].
Asbach, C ;
Kuhlbusch, TAJ ;
Fissan, H .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (09) :877-882
[2]   Development of an electrostatic partitioner for highly efficient partitioning of gas and particles with minimal effect on the gas phase [J].
Asbach, C ;
Kuhlbusch, TAJ ;
Fissan, H .
AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 (04) :322-329
[3]  
ASBACH C, 2004, P QA QC FIELD EM AIR, P191
[4]   TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations [J].
Ayers, GP ;
Keywood, MD ;
Gras, JL .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (22) :3717-3721
[5]   PERFORMANCE OF A UNIPOLAR SQUARE-WAVE DIFFUSION CHARGER WITH VARIABLE NT-PRODUCT [J].
BUSCHER, P ;
SCHMIDTOTT, A ;
WIEDENSOHLER, A .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (04) :651-663
[6]   Technical note: Performance of a personal electrostatic precipitator particle sampler [J].
Cardello, N ;
Volckens, J ;
Tolocka, MP ;
Wiener, R ;
Buckley, TJ .
AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (02) :162-165
[7]  
HINDS W, 1999, AEROSOL TECHNOLOGY, P330
[8]  
KUHLBUSCH TAJ, 2000, KORNGROSSENBHANGIGE
[9]   CONTINUOUS PM-10 MEASUREMENTS USING THE TAPERED ELEMENT OSCILLATING MICROBALANCE [J].
PATASHNICK, H ;
RUPPRECHT, EG .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (08) :1079-1083
[10]   Development of a reference standard for particulate matter mass in ambient air [J].
Patashnick, H ;
Rupprecht, G ;
Ambs, JL ;
Meyer, MB .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :42-45