Steady state of gradient echo sequences with radiofrequency phase cycling: Analytical solution, contrast enhancement with partial spoiling

被引:36
作者
Ganter, C [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost Radiol, D-81675 Munich, Germany
关键词
phase cycling; spoiled gradient echo; steady state; rapid imaging; RF spoiling;
D O I
10.1002/mrm.20736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spoiled gradient echo sequences can only reach a homogeneous steady state if sufficiently strong crusher gradients are used in combination with RF phase cycling (RF spoiling). However, the signal depends quite sensitively on the chosen phase increment phi and - lacking analytical solutions - numerical simulations must be used to study the transient and steady-state magnetization. For the steady state an exact analytical solution is derived, which holds for arbitrary sequence and tissue parameters. Besides a considerably improved computation performance, the analytical approach enables a better understanding of the complicated dependence on phi. For short repetition times (TR) the regime of small phi turns out to be particularly interesting: It is shown that the typical phi(c), where RF spoiling starts to become effective, is essentially inversely proportional to T-2. This tissue dependence implies that contrasts can be considerably larger with partial spoiling (phi approximate to phi(c)) than with conventional RF spoiling (phi >> phi(c)). As an example, the uptake of contrast agents in tissues is investigated. For typical parameters a considerably improved contrast enhancement can be obtained, both theoretically and experimentally.
引用
收藏
页码:98 / 107
页数:10
相关论文
共 16 条
[1]  
Abramowitz M., 1984, POCKETBOOK MATH FUNC
[2]   Steady-state preparation for spoiled gradient echo imaging [J].
Busse, RF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :653-661
[3]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[4]   Steady state effects in fast gradient echo magnetic resonance imaging [J].
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :559-568
[5]   Spoiling of transverse magnetization in gradient-echo (GRE) imaging during the approach to steady state [J].
Epstein, FH ;
Mugler, JP ;
Brookeman, JR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :237-245
[6]   Off-resonance effects in the transient response of SSFP sequences [J].
Ganter, C .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :368-375
[7]  
Hennig J., 1991, Concepts Magn Reson, V3, P125, DOI [10.1002/cmr.1820030302, DOI 10.1002/CMR.1820030302, 10.1002/CMR.1820030302]
[8]   DIFFUSION AND FIELD-GRADIENT EFFECTS IN NMR FOURIER SPECTROSCOPY [J].
KAISER, R ;
BARTHOLDI, E ;
ERNST, RR .
JOURNAL OF CHEMICAL PHYSICS, 1974, 60 (08) :2966-2979
[10]  
Teukolsky SA, 1992, NUMERICAL RECIPES C, VSecond