Correction of inhomogeneities in Magnetic Resonance Images

被引:0
|
作者
Noterdaeme, Olivier [1 ]
Brady, Michael [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Wolfson Med Vis Lab, Oxford OX1 3PJ, England
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4649637
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a method by which two fast spoiled gradient echo image volumes can be used to estimate the slowly varying intensity variation frequently observed in Magnetic Resonance Images (MRI). We first present results for simulated brain MRI, where we compare the performance of a segmentation algorithm on uncorrected, corrected and artifact free images. Next, we present the results for a real uniform phantom and then for clinical spinal images, where our algorithm reduces the intensity variation within a tissue class from a factor of 30 to a factor of 2. The technique and algorithm has been successfully tested on over 1000 images acquired with different coils, sequences and anatomies.
引用
收藏
页码:2221 / 2224
页数:4
相关论文
共 50 条
  • [1] SEGMENTATION OF MAGNETIC RESONANCE IMAGES IN PRESENCE OF SEVERE INTENSITY INHOMOGENEITIES
    Liebgott, Florian
    Wuerslin, Christian
    Yang, Bin
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 1013 - 1017
  • [2] Simultaneous Segmentation and Inhomogeneity Correction in Magnetic Resonance Images
    Li, Yue
    Hoover-Fong, Julie
    Carrino, John A.
    Mori, Susumu
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 8045 - 8048
  • [3] Evaluating intensity standardization and inhomogeneity correction in magnetic resonance images
    Madabhushi, A
    Udupa, JK
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 137 - 138
  • [4] Inhomogeneity correction of magnetic resonance images by minimization of intensity overlapping
    Gispert, JD
    Reig, S
    Pascau, J
    Martínez Lázaro, R
    Vaquero, JJ
    Desco, M
    2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 847 - 850
  • [5] Intensity Inhomogeneity Correction of Magnetic Resonance Images using Patches
    Roy, Snehashis
    Carass, Aaron
    Bazin, Pierre-Louis
    Prince, Jerry L.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [6] Inhomogeneity correction for brain magnetic resonance images by rank leveling
    Chen, J
    Reutens, DC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (05) : 668 - 676
  • [7] Automatic frequency correction for quantification of magnetic resonance spectroscopic images
    Wang, Y
    Van Huffel, S
    Heyvaert, E
    Vanhamme, L
    Van Hecke, P
    MATHEMATICS IN SIGNAL PROCESSING V, 2002, (71): : 229 - 239
  • [8] Correction of motion artifacts from cardiac cine magnetic resonance images
    Lötjönen, J
    Pollari, M
    Kivistö, S
    Lauerma, K
    ACADEMIC RADIOLOGY, 2005, 12 (10) : 1273 - 1284
  • [9] A universal method for geometric correction of magnetic resonance images for stereotactic neurosurgery
    Maciunas, RJ
    Fitzpatrick, JM
    Gadamsetty, S
    Maurer, CR
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 (1-3) : 137 - 140
  • [10] Bias Correction for Magnetic Resonance Images via Joint Entropy Regularization
    Wang, Shanshan
    Xia, Yong
    Dong, Pei
    Luo, Jianhua
    Huang, Qiu
    Feng, Dagan
    Li, Yuanxiang
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 1239 - 1245