Correlation between Corneal Endothelial Cell Density and Central Ocular Surface Temperature in Normal and Keratoconus Eyes

被引:3
|
作者
Nemeth, Orsolya [1 ,2 ,3 ]
Langenbucher, Achim [4 ]
Eppig, Timo [4 ]
Lepper, Sabine [5 ]
Milioti, Georgia [5 ]
Abdin, Aladin [5 ]
Nagy, Zoltan Zsolt [3 ]
Seitz, Berthold [5 ]
Szentmary, Nora [1 ,3 ]
机构
[1] Rolf M Schwiete Ctr Limbal Stem Cell & Congenital, D-66424 Homburg, Germany
[2] Markusovszky Univ Teaching Hosp, Dept Ophthalmol, Szombathely, Hungary
[3] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[4] Saarland Univ, Expt Ophthalmol, Homburg, Germany
[5] Saarland Univ, Med Ctr, Dept Ophthalmol, Homburg, Germany
关键词
Endothelial cell density; Ocular termography; Keratoconus;
D O I
10.1080/02713683.2020.1812087
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In keratoconus (KC), an increase of the corneal back surface area may result in endothelial cell density (ECD) decrease and an increase of the corneal front surface area in ocular surface temperature (OST) decrease due to increased heat dissipation. Along with these hypotheses, we aimed to analyse the correlation between ECD and central corneal OST in patients with KC and healthy controls. Patients and methods: A total of 154 eyes with KC (mean age 36.1 +/- 12.5 years) and 92 healthy eyes (mean age 36.4 +/- 12.8 years) were examined. Corneal front and back surface area at the central 5 mm corneal diameter (FSA and BSA) were calculated based on Pentacam measurement data: FSA or BSA = 2x3.14xR(R-root R-2-D/2)(2), where R referred to corneal front or back surface radius of curvature and D to the corneal front or back surface diameter (5 mm for the present study), respectively. ECD was determined by specular microscopy (EM-3000) and central corneal OST by thermography (TG-1000). Results: ECD was significantly lower in KC (2498 +/- 356/mm(2)) patients than in controls (2638 +/- 294/mm(2); p <.001). FSA (20.35 +/- 0.26 mm(2) vs. 20.17 +/- 0.03 mm(2)) and BSA (20.84 +/- 0.58 mm(2) vs. 20.45 +/- 0.08 mm(2)) were significantly higher in KC patients than in controls (p =.001; p <.001), but the average central corneal OST did not differ significantly between both groups (34.2 +/- 0.6 degrees C vs.34.3 +/- 0.7 degrees C; p =.62). OST at the corneal centre correlated weakly, positively with ECD (r = 0.2; p <.05), but OST did not correlate with FSA (r = 0.045) or BSA (r = 0.064). Conclusions: Endothelial cell density seems to have a mild impact on central ocular surface temperature in keratoconus and normal subjects. This effect is not correlated to the corneal front or back surface area.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 38 条
  • [31] Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post–LASIK or PRK, and keratoconic or keratoconus-suspect eyes
    Wenjing Wu
    Yan Wang
    Lulu Xu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 91 - 99
  • [32] Endothelial Cell Density and Central Corneal Thickness following Penetrating Keratoplasty of Acanthamoeba Keratitis Patients - A Retrospective Cross-Sectional Observational Study
    Shi, Lei
    Fries, Fabian Norbert
    Xanthopoulou, Kassandra
    Stachon, Tanja
    Daas, Loay
    Zemova, Elena
    Langenbucher, Achim
    Seitz, Berthold
    Szentmary, Nora
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2022, 239 (08) : 1007 - 1012
  • [33] Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes
    Wu, Wenjing
    Wang, Yan
    Xu, Lulu
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (01) : 91 - 99
  • [34] Association Between Corneal Endothelial Cell Density and Topical Glaucoma Medication Use in an Eye Bank Donor Population
    Kwon, Ji Won
    Rand, Gabriel M.
    Cho, Kyong Jin
    Gore, Patrick K.
    McCartney, Mitchell D.
    Chuck, Roy S.
    CORNEA, 2016, 35 (12) : 1533 - 1536
  • [35] S100A expression in normal corneal-limbal epithelial cells and ocular surface squamous cell carcinoma tissue
    Li, Jing
    Riau, Andri K.
    Setiawan, Melina
    Mehta, Jodhbir S.
    Ti, Seng-Ei
    Tong, Louis
    Tan, Donald T. H.
    Beuerman, Roger W.
    MOLECULAR VISION, 2011, 17 (245-46): : 2263 - 2271
  • [36] Outcomes after Descemet membrane endothelial keratoplasty over a period of 7 years at a tertiary referral center: endothelial cell density, central corneal thickness, and visual acuity
    Tarek Bayyoud
    Faik Gelisken
    Jens Martin Rohrbach
    Gunnar Blumenstock
    Karl Ulrich Bartz-Schmidt
    Sebastian Thaler
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 1907 - 1914
  • [37] Outcomes after Descemet membrane endothelial keratoplasty over a period of 7 years at a tertiary referral center: endothelial cell density, central corneal thickness, and visual acuity
    Bayyoud, Tarek
    Gelisken, Faik
    Rohrbach, Jens Martin
    Blumenstock, Gunnar
    Bartz-Schmidt, Karl Ulrich
    Thaler, Sebastian
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (07) : 1907 - 1914
  • [38] Corneal thickness and endothelial cell density measured by non-contact specular microscopy and pachymetry in Rhesus macaques (Macaca mulatta) with laser-induced ocular hypertension
    Ollivier, FJ
    Brooks, DE
    Komaromy, AM
    Kallberg, ME
    Andrew, SE
    Sapp, HL
    Sherwood, MB
    Dawson, WW
    EXPERIMENTAL EYE RESEARCH, 2003, 76 (06) : 671 - 677