Analysis of discharge energy on surge arrester configurations in 132 kV double circuit transmission lines

被引:7
|
作者
Hassan, Nor Hidayah Nor [1 ]
Abu Bakar, Ab Halim [2 ]
Illias, Hazlee Azil [1 ]
Abd Halim, Syahirah [1 ,4 ]
Mokhlis, Hazlie [1 ]
Terzija, Vladimir [3 ]
机构
[1] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Wisma R&D, UM Power Energy Dedicated Adv Ctr, Level 4,Jln Pantai Baharu, Kuala Lumpur 59990, Malaysia
[3] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
[4] Univ Kebangsaan Malaysia, Ctr Integrated Engn Syst & Adv Technol, Bangi, Malaysia
关键词
Transmission lines; Surge arrester; Lightning phenomena; Overvoltage; Discharge; TOWER;
D O I
10.1016/j.measurement.2019.02.088
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surge arrester has been proven to be the most effective application to provide optimum lightning protection for the transmission line. Thus, many works on optimizing lightning protection for transmission line have been conducted since the past. However, works on minimizing double circuit outages and surge arrester physical properties during transient overvoltages are less likely to be found. Therefore, in this work, several surge arrester configurations installed on a 132 kV double circuit transmission line were modelled using EMTP-RV to investigate their capability to withstand current and energy discharged by lightning strokes during back flashover phenomena. These configurations were then compared to determine the most effective protection design based on the actual tripping pattern recorded by the lightning detection system (LDS) in Malaysia. The selection was made by considering arresters' discharge energy due to variation in tower footing resistance, current magnitude, power frequency voltage, lightning tail time and front time, number of towers and span length. It was found that double circuit transmission line tripping can be completely eliminated by installing surge arresters at each phase conductor of one circuit. The selected arresters configuration provides sufficient lightning protection to the transmission line and complies with the discharge energy capability requirement specified by the utility company in Malaysia, of 5.1 kJ/kV for maximum continuous operating voltage (MCOV). (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 50 条
  • [31] LIGHTNING SURGE CURRENT MEASUREMENTS ON TELECOMMUNICATION LINES BY USING CARBON ARRESTER DISCHARGE VESTIGES.
    Ohtsuki, Fumio
    Koga, Hiroaki
    Motomitsu, Tamio
    Reports of the Electrical Communication Laboratory, 1983, 31 (04):
  • [32] Protection of double circuit transmission lines
    Apostolov, A.
    Tholomier, D.
    Sambasivan, S.
    Richards, S.
    2007 60TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2006, : 85 - 101
  • [33] Application of 800 kV SF6 dead tank circuit breaker with transmission line surge arrester to control switching transient overvoltages
    Musa, YI
    Keri, AJ
    Halladay, JA
    Jagtiani, AS
    Mandeville, JD
    Johnnerfelt, B
    Stenstrom, L
    Khan, AH
    Freeman, WB
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 2228 - 2228
  • [34] A neural network based protection technique for combined 275 kV/400 kV double circuit transmission lines
    Dept. of Electron. and Elec. Eng., University of Bath, Claverton Down, Bath BA2 7AY, United Kingdom
    不详
    Neurocomputing, 1-3 (59-70):
  • [35] A neural network based protection technique for combined 275 kV 400 kV double circuit transmission lines
    Xuan, QY
    Aggarwal, RK
    Johns, AT
    Dunn, RW
    Bennett, A
    NEUROCOMPUTING, 1998, 23 (1-3) : 59 - 70
  • [36] A study of Degradation Characteristics and Diagnostic Method of Lightning Surge Arrester for 6.6 kV Power Distribution Lines
    Yoneda, Yasuaki
    Koga, Yoshiyasu
    Sato, Tomoyuki
    Yokoyama, Shigeru
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [37] Assessment of surge arrester failure rate and application studies in Hellenic high voltage transmission lines
    Christodoulou, C. A.
    Ekonomou, L.
    Fotis, G. P.
    Gonos, I. F.
    Stathopulos, I. A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (02) : 176 - 183
  • [38] Calculation and Analysis on Unbalanced Currents of Yandun-Tianshan 750kV Double-circuit Transmission Lines
    Wang X.
    Xiang Z.
    Song X.
    Liang S.
    Li S.
    Wang C.
    Fu T.
    Dianwang Jishu/Power System Technology, 2022, 46 (07): : 2842 - 2849
  • [39] Statistical Analysis of Radio Interference of 1000 kV UHV AC Double-circuit Transmission Lines in Foul Weather
    Xie, Huichun
    Cui, Xiang
    Wan, Baoquan
    Zhang, Jiangong
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (02): : 47 - 55
  • [40] Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines
    Wu, Shihong
    Wen, Xishan
    Li, Rui
    Xu, Yang
    Lecture Notes in Electrical Engineering, 2015, 334 : 389 - 397