Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements

被引:12
作者
Harris, C. [1 ]
Alcock, A. [2 ]
Trefan, L. [3 ]
Nuttall, D. [3 ]
Evans, S. T. [4 ]
Maguire, S. [3 ,5 ]
Kemp, A. M. [5 ]
机构
[1] Queen Elizabeth Hosp Birmingham, Univ Hosp Birmingham NHS Fdn Trust, Birmingham, W Midlands, England
[2] Royal Gwent Hosp, Aneurin Bevan Univ Hlth Board, Newport, Shrops, England
[3] Cardiff Univ, Coll Biomed & Life Sci, Sch Med, Heath Pk, Cardiff, S Glam, Wales
[4] Cardiff Univ, Coll Biomed & Life Sci, Sch Dent, Dent Photog, Heath Pk, Cardiff, S Glam, Wales
[5] Cardiff Univ, Coll Biomed & Life Sci, Div Populat Med, Heath Pk, Cardiff CF14 4YS, S Glam, Wales
基金
英国医学研究理事会;
关键词
Bruise measurement; Conventional imaging; Cross polarized imaging; Maximum Feret; Image J; RELIABILITY;
D O I
10.1016/j.jflm.2017.12.020
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Background: Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. Methods: 24 children aged < 11 years (mean age of 6.9, range 2.5-10 years) with a bruise were recruited from the community. Demographics and bruise details were recorded. Each bruise was measured in vivo using a paper measuring tape. Standardised conventional and cross polarized digital images were obtained. The diameter of bruise images were measured by three computer aided measurement techniques: Image J (segmentation with Simple Interactive Object Extraction (maximum Feret diameter), 'Circular Selection Tool' (Circle diameter), & the Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p < 0.05 for all tests. Results: Images were available for 38 bruises in vivo, with 48 bruises visible on cross polarized imaging and 46 on conventional imaging (some bruises interpreted as being single in vivo appeared to be multiple in digital images). Correlation coefficients were > 0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter-and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Conclusions: Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 31 条
  • [1] Abramoff M.D., 2004, Biophotonics Int., V11, P36
  • [2] Altman D., 1992, PRACTICAL STAT MED R, P2
  • [3] [Anonymous], 2000, DIGITAL ANAL BITE MA
  • [4] [Anonymous], BIT MARK GUID
  • [5] [Anonymous], 2008, Digital image processing
  • [6] Baker H.C., 2013, J FORENSIC IDENTIFIC, V63, P103
  • [7] A pilot study to measure marks in children with cerebral palsy using a novel measurement template
    Bennett, T.
    Jellinek, D.
    Bennett, M.
    [J]. CHILD CARE HEALTH AND DEVELOPMENT, 2013, 39 (06) : 864 - 868
  • [8] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [9] Reliability of Vascular Access Site Bruise Measurement
    Cosman, Tammy L.
    Arthur, Heather M.
    Bryant-Lukosius, Denise
    Strachan, Patricia H.
    [J]. JOURNAL OF NURSING MEASUREMENT, 2015, 23 (01) : 179 - 200
  • [10] Cross-Polarisation, Making it Practical
    Edwards, Nathan
    [J]. JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (04) : 165 - 172