Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

被引:66
作者
Heuschmid, M
Rothfuss, JK
Schroeder, S
Fenchel, M
Stauder, N
Burgstahler, C
Franow, A
Kuzo, RS
Kuettner, A
Miller, S
Claussen, CD
Kopp, AF
机构
[1] Univ Tubingen Hosp, Dept Diagnost Radiol, D-72070 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Cardiol, D-72070 Tubingen, Germany
[3] Mayo Clin, Dept Radiol, Jacksonville, FL 32224 USA
关键词
multidetector-row computed tomography; magnetic resonance imaging; echocardiography; cardiac imaging; functional parameters;
D O I
10.1007/s00330-005-0015-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). Materials and Methods: End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. Results: A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. Conclusions: MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 46 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT [J].
Boehm, T ;
Alkadhi, H ;
Roffi, M ;
Willmann, JK ;
Desbiolles, LM ;
Marincek, B ;
Wildermuth, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :529-537
[5]   Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography [J].
Coche, E ;
Vlassenbroek, A ;
Roelants, V ;
D'Hoore, W ;
Verschuren, F ;
Goncette, L ;
Maldague, B .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1432-1440
[6]   Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[7]  
de Simone Giovanni, 2002, Ital Heart J, V3, P562
[8]   Multi-slice CT (MSCT) in cardiac function imaging: Threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI [J].
Ehrhard, K ;
Oberholzer, K ;
Gast, K ;
Mildenberger, P ;
Kreitner, KF ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12) :1566-1569
[9]   LONG-TERM SURVIVAL OF MEDICALLY TREATED PATIENTS IN THE CORONARY-ARTERY SURGERY STUDY (CASS) REGISTRY [J].
EMOND, M ;
MOCK, MB ;
DAVIS, KB ;
FISHER, LD ;
HOLMES, DR ;
CHAITMAN, BR ;
KAISER, GC ;
ALDERMAN, E ;
KILLIP, T .
CIRCULATION, 1994, 90 (06) :2645-2657
[10]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027