PERIPROSTHETIC BONE TURNOVER AFTER PRIMARY TOTAL HIP ARTHROPLASTY MEASURED BY SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY

被引:13
作者
Venesmaa, P. [1 ,2 ]
Vanninen, E. [3 ,4 ]
Miettinen, H. [1 ]
Kroger, H. [1 ,2 ]
机构
[1] Kuopio Univ Hosp, Dept Orthoped & Traumatol, FI-70210 Kuopio, Finland
[2] Univ Eastern Finland, BCRU, Kuopio, Finland
[3] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, FI-70210 Kuopio, Finland
[4] Univ Kuopio, FIN-70211 Kuopio, Finland
关键词
Total hip arthroplasty; single-photon emission computed tomography; bone turnover; bone mineral density; periprosthetic bone; dual-energy X-ray absorptiometry; X-RAY ABSORPTIOMETRY; FEMORAL COMPONENTS; FOLLOW-UP; SCINTIGRAPHY; REPLACEMENT; SPECT;
D O I
10.1177/145749691210100404
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and Aims: Alterations in periprosthetic bone are common sequlae of prosthetic implants. This prospective 3-year study was performed to follow regional periprosthetic bone turnover after uncomplicated total hip arthroplasty (THA) using single-photon emission computed tomography (SPECT). Material and Methods: Eighteen patients (nine men, nine women: mean age 61 years, range from 50 to 73 years) with primary hip osteoarthritis underwent either uncemented or cemented THA. The SPECT measurements were taken 6, 12, and 36 months after THA. Bone mineral density (BMD) measurements were performed on the patients during follow-up. Results: The mean SPECT uptake ratios decreased significantly in the regions of interest (ROIs) during follow-up compared to baseline value, in the trochanter major (p = 0.006), the trochanter minor (p = 0.009) and the total area (p = 0.018). Despite these decreases the uptake ratios in the medial cortex (p = 0.014), tip (p = 0.002) and total area (p = 0.016) remained significantly higher in the operated side than in the contralateral side (non-operated) 3 years after THA. Changes in bone turnover in the vicinity of the implant did not correlate with changes in periprosthetic BMD. Conclusions: Local periprosthetic bone turnover decreased slowly after THA and did not recover to the level typical of non-operated hips. This led us to suggest that bone turnover around the femoral implants remains increased more than 3 years after THA even if there are no signs of failure of the prosthesis.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 23 条
[1]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[2]  
COLLIER BD, 1985, J NUCL MED, V26, P979
[3]  
Collier Jr DB, 1996, SKELETAL NUCL MED, P45
[4]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
[5]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[6]   TOTAL HIP AND TOTAL KNEE REPLACEMENT .1. [J].
HARRIS, WH ;
SLEDGE, CB .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (11) :725-731
[7]  
HUISKES R, 1992, CLIN ORTHOP RELAT R, P124
[8]   BONE LOSS IN PATIENTS WITH CHRONIC RENAL-DISEASE - PREDICTION WITH QUANTITATIVE BONE-SCINTIGRAPHY WITH SPECT [J].
ISRAEL, O ;
GIPS, S ;
HARDOFF, R ;
RUDOY, J ;
FRAJEWICKI, V ;
IOSILEVSKY, G ;
BETTMAN, L ;
FRENKEL, A ;
HOFFMAN, A ;
KOLODNY, GM ;
FRONT, D .
RADIOLOGY, 1995, 196 (03) :643-646
[9]   CLINICAL AND RADIOGRAPHIC EVALUATION OF TOTAL HIP-REPLACEMENT - A STANDARD SYSTEM OF TERMINOLOGY FOR REPORTING RESULTS [J].
JOHNSTON, RC ;
FITZGERALD, RH ;
HARRIS, WH ;
POSS, R ;
MULLER, ME ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :161-168
[10]   DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL DENSITY AROUND POROUS-COATED CEMENTLESS FEMORAL IMPLANTS - METHODS AND PRELIMINARY-RESULTS [J].
KILGUS, DJ ;
SHIMAOKA, EE ;
TIPTON, JS ;
EBERLE, RW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :279-287