SlicerRT: Radiation therapy research toolkit for 3D Slicer

被引:181
|
作者
Pinter, Csaba [1 ]
Lasso, Andras [1 ]
Wang, An [2 ]
Jaffray, David [2 ]
Fichtinger, Gabor [1 ]
机构
[1] Queens Univ, Lab Percutaneous Surg, Sch Comp, Kingston, ON K7L 3N6, Canada
[2] Univ Hlth Network, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
关键词
radiation therapy; 3D Slicer; DICOM-RT; dose volume histogram; dose comparison; RADIOTHERAPY; PROSTATE;
D O I
10.1118/1.4754659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Interest in adaptive radiation therapy research is constantly growing, but software tools available for researchers are mostly either expensive, closed proprietary applications, or free open-source packages with limited scope, extensibility, reliability, or user support. To address these limitations, we propose SlicerRT, a customizable, free, and open-source radiation therapy research toolkit. SlicerRT aspires to be an open-source toolkit for RT research, providing fast computations, convenient workflows for researchers, and a general image-guided therapy infrastructure to assist clinical translation of experimental therapeutic approaches. It is a medium into which RT researchers can integrate their methods and algorithms, and conduct comparative testing. Methods: SlicerRT was implemented as an extension for the widely used 3D Slicer medical image visualization and analysis application platform. SlicerRT provides functionality specifically designed for radiation therapy research, in addition to the powerful tools that 3D Slicer offers for visualization, registration, segmentation, and data management. The feature set of SlicerRT was defined through consensus discussions with a large pool of RT researchers, including both radiation oncologists and medical physicists. The development processes used were similar to those of 3D Slicer to ensure software quality. Standardized mechanisms of 3D Slicer were applied for documentation, distribution, and user support. The testing and validation environment was configured to automatically launch a regression test upon each software change and to perform comparison with ground truth results provided by other RT applications. Results: Modules have been created for importing and loading DICOM-RT data, computing and displaying dose volume histograms, creating accumulated dose volumes, comparing dose volumes, and visualizing isodose lines and surfaces. The effectiveness of using 3D Slicer with the proposed SlicerRT extension for radiation therapy research was demonstrated on multiple use cases. Conclusions: A new open-source software toolkit has been developed for radiation therapy research. SlicerRT can import treatment plans from various sources into 3D Slicer for visualization, analysis, comparison, and processing. The provided algorithms are extensively tested and they are accessible through a convenient graphical user interface as well as a flexible application programming interface. (c) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4754659]
引用
收藏
页码:6332 / 6338
页数:7
相关论文
共 50 条
  • [21] Morphological and Volumetric Assessment of Cerebral Ventricular System with 3D Slicer Software
    Gonzalo Dominguez, Miguel
    Hernandez, Cristina
    Ruisoto, Pablo
    Juanes, Juan A.
    Prats, Alberto
    Hernandez, Tomas
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (06)
  • [22] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [23] Postoperative volumetric modulated arc therapy for sinonasal cancer: Improved survival compared with 3D conformal radiation therapy
    Frederic-Moreau, Thomas
    Piram, Lucie
    Bellini, Romain
    Martin, Fanny
    Miroir, Jessica
    Saroul, Nicolas
    Dang, Nathalie Pham
    Lapeyre, Michel
    Biau, Julian
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (02): : 448 - 455
  • [24] matRad - a multi-modality open source 3D treatment planning toolkit
    Cisternas, E.
    Mairani, A.
    Ziegenhein, P.
    Jaekel, O.
    Bangert, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 1608 - 1611
  • [25] Using fuzzy logics to determine optimal oversampling factor for voxelizing 3D surfaces in radiation therapy
    Pinter, C.
    Olding, T.
    Schreiner, L. J.
    Fichtinger, G.
    SOFT COMPUTING, 2020, 24 (24) : 18959 - 18970
  • [26] Using fuzzy logics to determine optimal oversampling factor for voxelizing 3D surfaces in radiation therapy
    C. Pinter
    T. Olding
    L. J. Schreiner
    G. Fichtinger
    Soft Computing, 2020, 24 : 18959 - 18970
  • [27] 3D printed integrated bolus/headrest for radiation therapy for malignancies involving the posterior scalp and neck
    Hsu, Eric J.
    Parsons, David
    Chiu, Tsuicheng
    Godley, Andrew R.
    Sher, David J.
    Vo, Dat T.
    3D PRINTING IN MEDICINE, 2022, 8 (01)
  • [28] Development and evaluation of a "trackerless" surgical planning and guidance system based on 3D Slicer
    Yang, Xiaochen
    Narasimhan, Saramati
    Luo, Ma
    Thompson, Reid C.
    Chambless, Lola B.
    Morone, Peter J.
    He, Le
    Dawant, Benoit M.
    Miga, Michael, I
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [29] ImageAugmenter: A user-friendly 3D Slicer tool for medical image augmentation
    Raggio, Ciro Benito
    Zaffino, Paolo
    Spadea, Maria Francesca
    SOFTWAREX, 2024, 28
  • [30] ColocZStats: a z-stack signal colocalization extension tool for 3D slicer
    Chen, Xiang
    Thakur, Teena
    Jeyasekharan, Anand D.
    Benoukraf, Touati
    Meruvia-Pastor, Oscar
    FRONTIERS IN PHYSIOLOGY, 2024, 15