Polyaniline/Prussian-Blue-Based Amperometric Biosensor for Detection of Uric Acid

被引:44
作者
Thakur, Bhawana [1 ]
Sawant, Shilpa N. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Chem, Bombay 400085, Maharashtra, India
来源
CHEMPLUSCHEM | 2013年 / 78卷 / 02期
关键词
biosensors; catalysis; electrochemistry; H2O2; reduction; polyaniline; Prussian blue; uric acid; PRUSSIAN-BLUE; HYDROGEN-PEROXIDE; SELECTIVE DETECTION; GLUCOSE; OXIDASE; ENZYME; HYBRID; SENSOR; FILMS; NANOPARTICLES;
D O I
10.1002/cplu.201200222
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Polyaniline/Prussian blue (PANI-PB) composite was electrochemically deposited on a platinum electrode. The properties of the PANI-PB-modified electrode were exploited in terms of its response toward H2O2 sensing by using cyclic voltammetry, and were found to be more effectual than the PANI-modified electrode in the low-potential range. The PANI-PB-modified electrode was further used for the bioanalysis of uric acid by immobilization of the enzyme uricase. The electrode was characterized at various stages of modification by scanning electron microscopy (SEM), IR spectroscopy, and cyclic voltammetry. The biosensor gave a linear response for uric acid in the concentration range 10160M with a sensitivity of 160AmM1cm2. The main advantage of the PANI-PB composite electrode is its low working potential (0V vs. Ag/AgCl) for the estimation of uric acid, which enables the elimination of plausible interfering effects caused by analytes present in real samples. The biosensor was selective to uric acid and did not respond to analytes such as ascorbic acid, glucose, and urea. The sensor electrode retained its selectivity and sensitivity for seven days if stored at 18 degrees C. The biosensor also displayed a satisfactory performance for the detection of uric acid in human blood serum samples.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 58 条
[1]   Selective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires [J].
Ali, Syed M. Usman ;
Alvi, N. H. ;
Ibupoto, Zafar ;
Nur, Omer ;
Willander, Magnus ;
Danielsson, Bengt .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02) :241-247
[2]   Performance of SLS/MWCNTs/PANI capacitor electrodes in a physiological electrolyte and in serum [J].
Ammam, Malika ;
Fransaer, Jan .
CHEMICAL COMMUNICATIONS, 2012, 48 (14) :2036-2038
[3]   ALLOPURINOL HYPERSENSITIVITY SYNDROME - A REVIEW [J].
ARELLANO, F ;
SACRISTAN, JA .
ANNALS OF PHARMACOTHERAPY, 1993, 27 (03) :337-343
[4]   Fabrication of dissolved O2 metric uric acid biosensor using uricase epoxy resin biocomposite membrane [J].
Arora, Jyoti ;
Nandwani, Seep ;
Bhambi, Manu ;
Pundir, C. S. .
ANALYTICA CHIMICA ACTA, 2009, 647 (02) :195-201
[5]   Highly sensitive and selective uric acid biosensor based on RF sputtered NiO thin film [J].
Arora, Kashima ;
Tomar, Monika ;
Gupta, Vinay .
BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) :333-336
[6]   Improved performance of polyaniline-uricase biosensor [J].
Arora, Kavita ;
Sumana, G. ;
Saxena, Vibha ;
Gupta, R. K. ;
Gupta, S. K. ;
Yakhmi, J. V. ;
Pandey, M. K. ;
Chand, Subhash ;
Malhotra, B. D. .
ANALYTICA CHIMICA ACTA, 2007, 594 (01) :17-23
[7]   Designing an amperometric thick-film microbial BOD sensor [J].
Chan, CY ;
Lehmann, M ;
Chan, KM ;
Chan, PY ;
Chan, CW ;
Gruendig, B ;
Kunze, G ;
Renneberg, R .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (7-8) :343-353
[8]   Application of polyaniline/sol-gel derived tetraethylorthosilicate films to an amperometric lactate biosensor [J].
Chaubey, A ;
Pande, KK ;
Malhotra, BD .
ANALYTICAL SCIENCES, 2003, 19 (11) :1477-1480
[9]   An amperometric uric acid biosensor based on multiwalled carbon nanotube-gold nanoparticle composite [J].
Chauhan, Nidhi ;
Pundir, Chandra Shekhar .
ANALYTICAL BIOCHEMISTRY, 2011, 413 (02) :97-103
[10]   Recent advances in electrochemical sensing for hydrogen peroxide: a review [J].
Chen, Wei ;
Cai, Shu ;
Ren, Qiong-Qiong ;
Wen, Wei ;
Zhao, Yuan-Di .
ANALYST, 2012, 137 (01) :49-58