Amperometric detection of Nitrite, Iodate and Periodate on Glassy Carbon Electrode modified with Thionin and Multi-wall Carbon Nanotubes

被引:0
|
作者
Salimi, Abdollah [1 ]
Noorbakhash, Abdollah [1 ]
Karonian, Fatemeh Salehi [1 ]
机构
[1] Kurdistan Univ, Sanandaj, Iran
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2006年 / 1卷 / 08期
关键词
Thionin; multiwall carbon nanotubes; glassy carbon; nitrite; iodate; periodate; determination;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The multi-wall carbon nanotubes were used as an immobilization matrix to incorporate thionin as electron transfer mediator onto a glassy carbon electrode surface. Due to unique electronic properties of MWCNTs and electrocatalytic activity of thionin, the combination of thionin and MWCNTs results in a remarkable synergistic augmentation on the response. A chemically modified electrode prepared by adsorption of thioinin on CNT shows excellent catalytic activity for reduction iodate, periodate and nitrite in acidic buffer solutions at unusual positive and it can be used as stable and sensitive sensor for these analytes. The results indicated that the modified electrode exhibited efficiently electrocatalytic reduction for iodate, periodate and nitrite in acidic buffer solutions at unusual positive potential. Nitrite, iodate and periodate were determined amperomerically on rotated modified electrode in pH 2. Under optimized condition in amperometry method the concentration calibration range, detection limit and sensitivity were about, 1 mu M -10mM, 0.4 mu M and 12.44 nA/mu M for periodate, 2.0 mu M -10 mM, 1 mu M and 5.36 nA/mu M for iodate and 6 mu M-15 mM, 4 mu M and 2 nA/mu M for nitrite. The catalytic rate constants for oxoanions reduction were determined by cyclic voltammetry method based on the Laviron theory, they were about 1.34 x 10(4), 1.68 x 10(4) and 4.93 x 10(3) M-1 s(-1), for iodate, periodate and nitrite, respectively. The resultant thionin / MWCNTs modified glassy carbon electrodes exhibit high catalytic activity, fast response time (within 5 s) to above anions reduction, excellent stability, long term life and good reproducibility. This sensor indicate great promise as an amperometry detector for analysis of nitrite, iodate and periodate in chromatographic or flow systems.
引用
收藏
页码:435 / 445
页数:11
相关论文
共 50 条
  • [1] Amperometric detection of nitrite, iodate and periodate at glassy carbon electrode modified with catalase and multi-wall carbon nanotubes
    Salimi, Abdollah
    Noorbakhsh, Abdollah
    Ghadermarzi, Mohammad
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01): : 530 - 537
  • [2] Electrochemical behaviours of scutellarin at multi-wall carbon nanotubes modified glassy carbon electrode
    Cai, Zhuo
    Yue, Weichao
    Gan, Jingni
    Peng, Yue
    He, Xiaoliang
    PROGRESS IN MATERIALS AND PROCESSES, PTS 1-3, 2013, 602-604 : 239 - 242
  • [3] Electrochemical Behaviours of Daidzein at Multi-Wall Carbon Nanotubes Modified Glassy Carbon Electrode
    Cai, Z.
    Gan, J. N.
    Lu, D. F.
    Zhang, X.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (11) : 4986 - 4990
  • [4] Study on electrochemical behavior of Tyrosine at multi-wall carbon nanotubes modified glassy carbon electrode
    Shao, Chen
    Wei, Yingliang
    Jiang, Ling
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2008, 11 (03) : 175 - 179
  • [5] Hematoxylin multi-wall carbon nanotubes modified glassy carbon electrode for electrocatalytic oxidation of hydrazine
    Zare, Hamid R.
    Nasirizadeh, Navid
    ELECTROCHIMICA ACTA, 2007, 52 (12) : 4153 - 4160
  • [6] Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
    Tefera, M.
    Tessema, M.
    Admassie, S.
    Mehretie, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (02): : 139 - 150
  • [7] Voltammetric behavior and determination of phenylephrine at a glassy carbon electrode modified with multi-wall carbon nanotubes
    Zhu, Yuan-hai
    Zhang, Zhi-ling
    Zhao, Wei
    Pang, Dai-wen
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 308 - 314
  • [8] Nafion/Multi-wall Carbon Nanotubes Composite Modified Glassy Carbon Electrode for Sensitive Determination of Bilirubin
    Filik, Hayati
    Avan, Asiye A.
    Aydar, Sevda
    CURRENT NANOSCIENCE, 2015, 11 (06) : 784 - 791
  • [9] Electrocatalytic actoin of metol at modified glassy carbon electrode of multi-wall carbon nanotubes and its application
    Wang, YC
    Li, JY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (03) : 375 - 378
  • [10] Amperometric detection of carbohydrates and thiols by using a glassy carbon electrode coated with Co oxide/multi-wall carbon nanotubes catalytic system
    Buratti, Susanna
    Brunetti, Barbara
    Mannino, Saverio
    TALANTA, 2008, 76 (02) : 454 - 457