High-spatial-resolution 3D balanced turbo field-echo technique for MR angiography of the renal arteries: Initial experience

被引:0
作者
Coenegrachts, KL
Hoogeveen, RM
Vaninbroukx, JA
Bosmans, HT
Bielen, DJ
Maleux, G
Maes, F
Hamaekers, P
Oyen, RH
Marchal, GJ
机构
[1] Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
[2] Univ Hosp Gasthuisberg, Lab Med Imaging Res, B-3000 Louvain, Belgium
[3] Philips Med Syst, Best, Netherlands
关键词
magnetic resonance (MR); three-dimensional; vascular studies; renal arteries; stenosis or obstruction;
D O I
10.1148/radiol.2311030044
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare a multislab balanced turbo field-echo magnetic resonance (MR) angiographic technique, without the use of a contrast agent, with digital subtraction angiography (DSA) for imaging of the renal arteries. MATERIALS AND METHODS: Twenty-five randomly selected patients (eight women and 17 men; age range, 27-88 years; mean age, 72 years) suspected of having renal artery stenosis underwent both DSA and balanced turbo field-echo MR angiography. A consensus result was obtained among three radiologists in evaluation of main renal arteries on balanced turbo field-echo images and DSA images. Sensitivity, specificity, and negative and positive predictive values of the balanced turbo field-echo technique were calculated, and receiver operating characteristic analysis was performed for depiction of hemodynamically significant stenosis. Cohen kappa analysis was used to assess agreement between the two imaging methods in grading of stenoses and depiction of significant stenosis. Accessory renal arteries also were evaluated. RESULTS: Fifty main renal arteries and 11 accessory arteries were fully depicted with DSA. DSA depicted 11 stenotic lesions in the main renal arteries. In comparison, balanced turbo field-echo MR angiography enabled visualization of 46 of 50 main renal arteries to their first branching points and depicted 10 of 11 accessory arteries. Sensitivity, specificity, negative predictive value, and positive predictive value of this technique for depiction of significant stenosis were 100% (four of four), 98% (41 of 42), 100% (41 of 41), and 80% (four of five), respectively. The area under the receiver operating characteristic curve was 0.988. kappa was 0.782 for grading of stenoses and 0.877 for depiction of significant stenosis. CONCLUSION: Multislab balanced turbo field-echo imaging has potential as an MR angiography technique for depiction of normal and diseased renal arteries. (C) RSNA, 2004.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 16 条
[1]   INTRACRANIAL MRA - SINGLE VOLUME VS MULTIPLE THIN SLAB 3D TIME-OF-FLIGHT ACQUISITION [J].
DAVIS, WL ;
WARNOCK, SH ;
HARNSBERGER, HR ;
PARKER, DL ;
CHEN, CX .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (01) :15-21
[2]   Diagnosis of renal vascular disease with MR angiography [J].
Dong, Q ;
Schoenberg, SO ;
Carlos, RC ;
Neimatallah, M ;
Cho, KJ ;
Williams, DM ;
Kazanjian, SN ;
Prince, MR .
RADIOGRAPHICS, 1999, 19 (06) :1535-1554
[3]  
Duda SH, 1997, ACTA RADIOL, V38, P287
[4]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362
[5]  
HOOGEVEEN RM, 2002, P 10 M INT SOC MAGN, P1762
[6]  
LEWIN JS, 1992, INVEST RADIOL, V27, P84
[7]   Transplant renal artery stenosis - Evaluation of diagnosis with magnetic resonance angiography compared with color duplex sonography and arteriography [J].
Loubeyre, P ;
Cahen, R ;
Grozel, F ;
Trolliet, P ;
PouteilNoble, C ;
Labeeuw, M ;
Minh, VT .
TRANSPLANTATION, 1996, 62 (04) :446-450
[8]   SCREENING PATIENTS FOR RENAL-ARTERY STENOSIS - VALUE OF 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
LOUBEYRE, P ;
REVEL, D ;
GARCIA, P ;
DELIGNETTE, A ;
CANET, E ;
CHIROSSEL, P ;
GENIN, G ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (04) :847-852
[9]   Contrast-enhanced MR angiography [J].
Maki, JH ;
Chenevert, TL ;
Prince, MR .
ABDOMINAL IMAGING, 1998, 23 (05) :469-484
[10]   Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis [J].
Masunaga, H ;
Takehara, Y ;
Isoda, H ;
Igarashi, T ;
Sugiyama, M ;
Isogai, S ;
Kodaira, N ;
Takeda, H ;
Nozaki, A ;
Sakahara, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1213-1219