Defining the radiation "scatter cloud" in the interventional suite

被引:16
作者
Haqqani, Omar P.
Agarwal, Prakhar K.
Halin, Neil M.
Iafrati, Mark D.
机构
[1] Department of Vascular Surgery, Cardiovascular Center, Tufts Medical Center, Boston, MA
[2] Department of Vascular Surgery, Mid Michigan Medical Offices, Midland, MI 48640
关键词
CARDIAC-CATHETERIZATION PROCEDURES; EXPOSURE; PATIENT;
D O I
10.1016/j.jvs.2013.01.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: We hypothesized that fluoroscopic imaging creates radiation fields that are unevenly scattered throughout the endovascular suite. We sought to quantify the radiation dose spectrum at various locations during imaging procedures and to represent this in a clinically useful manner. Methods: Digital subtraction imaging (Innova 4100; GE Healthcare, Waukesha, Wisc) of the abdomen and pelvis was performed on a cadaver in anteroposterior, left lateral, and right anterior oblique 45 degrees projections. Radiation exposure was monitored in real time with DoseAware dosimeters (Phillips, Houston, Tex) in eight radial projections at distances of 2, 4, and 6 ft from the center of the imaged field, each at 5-ft heights from the floor. Three to five consecutive data points were collected for each location. Results: At most positions around the angiographic table, radiation exposure decreased as the distance from the source emitter increased; however, the intensity of the exposure varied dramatically around the axis of imaging. With anteroposterior imaging, the radiation fields have symmetric dumbbell shapes, with maximal exposure perpendicular to the table at the level of the gantry. Peak levels at 4 and 6 ft from the source emitter were 2.4 times and 3.4 times higher, respectively, than predicted based on the inverse square law. Maximal radiation exposure was measured in the typical operator position 2 ft away and perpendicular to the table (4.99 mSv/h). When the gantry was rotated 45 degrees and 90 degrees, the radiation fields shifted, becoming more asymmetric, with increasing radiation doses to 10.9 and 69 mSv/h, respectively, on the side of the emitter. Minimal exposure is experienced along the axis of the table, decreasing with distance from the source (<0.77 mSv/h). Conclusions: Quantifiable and reproducible radiation scatter is created during interventional procedures. Radiation doses vary widely around the perimeter of the angiography table and change according to imaging angles. These data are easily visualized using contour plots and scatter three-dimensional mesh plots. Rather than the concentric circles predicted by the inverse square law, these data more closely resemble a "scatter cloud." Knowledge of the actual exposure levels within the endovascular environment may help in mitigating these risks to health care providers.
引用
收藏
页码:1339 / 1345
页数:7
相关论文
共 14 条
  • [1] [Anonymous], BMC ANESTHESIOL, DOI DOI 10.1186/1471-2253-3-2
  • [2] Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography
    Hayashi, N
    Sakai, T
    Kitagawa, M
    Inagaki, R
    Yamamoto, F
    Fukushima, T
    Ishii, Y
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (03) : 240 - 243
  • [3] Occupational radiation doses to operators performing cardiac catheterization procedures
    Kim, Kwang Pyo
    Miller, Donald L.
    Balter, Stephen
    Kleinerman, Ruth A.
    Linet, Martha S.
    Kwon, Deukwoo
    Simon, Steven L.
    [J]. HEALTH PHYSICS, 2008, 94 (03): : 211 - 227
  • [4] Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review
    Kim, Kwang Pyo
    Miller, Donald L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 227 - 233
  • [5] Occupational Health Hazards in the Interventional Laboratory: Time for a Safer Environment (Reprinted from J Vasc Interv Radiol vol 20, pg 147-152, 2009)
    Klein, Lloyd W.
    Miller, Donald L.
    Balter, Stephen
    Laskey, Warren
    Haines, David
    Norbash, Alexander
    Mauro, Matthew A.
    Goldstein, James A.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) : S278 - S283
  • [6] Identification of less-irradiating tube angulations in invasive cardiology
    Kuon, E
    Dahm, JB
    Empen, K
    Robinson, DM
    Reuter, G
    Wucherer, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (07) : 1420 - 1428
  • [7] PATIENT AND STAFF DOSIMETRY IN NEURORADIOLOGICAL PROCEDURES
    MARSHALL, NW
    NOBLE, J
    FAULKNER, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) : 495 - 501
  • [8] OVERVIEW OF CONTEMPORARY INTERVENTIONAL FLUOROSCOPY PROCEDURES
    Miller, Donald L.
    [J]. HEALTH PHYSICS, 2008, 95 (05): : 638 - 644
  • [9] Mitchell EL, 2011, J VASC SURG, V53, P22
  • [10] Roth J, 1996, SCHWEIZ MED WSCHR, V126, P1157