Measurement of Residual Charge using Pulse Voltages for Water Tree Degraded XLPE Cables Diagnosis

被引:1
|
作者
Kurihara, Takashi [1 ]
Okamoto, Tatsuki [1 ]
Kim, Myong Hwan [2 ]
Hozumi, Naohiro [2 ]
Tsuji, Taizo [3 ]
Uchida, Katsumi [3 ]
机构
[1] Cent Res Inst Elect Power Ind, Yokosuka, Kanagawa 2400196, Japan
[2] Toyohashi Univ Technol, Toyohashi, Aichi 4418580, Japan
[3] Chubu Elect Power Co Inc, Midori Ku, Nagoya, Aichi 4598522, Japan
关键词
XLPE cable; water trees; degradation diagnostic method; residual charge method; pulse voltage; DIELECTRIC RESPONSE MODEL; POLYETHYLENE; DETERIORATION; SPECTROSCOPY; MECHANISMS; INSULATION; PART;
D O I
10.1109/TDEI.2013.004069
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The residual charge method is one of the main degradation diagnostic methods for water tree degradation of XLPE cables. In this method, a DC voltage is applied to a water tree-degraded XLPE cable in order to accumulate space charges in water tree parts of an XLPE cable, and an AC voltage is applied to it in order to release deeply trapped space charges, i.e. residual charges. The authors have been developing a new diagnostic method with pulse voltages instead of DC and AC voltages since the method can be applied to the XLPE cables that are connected to gas insulated switchgears. If a diagnostic method using pulse voltages for water tree-degraded XLPE cables is developed, the improvement of the detection sensibility for signals related to water trees is expected because of the averaging effect of signals by the repeated application of pulse voltages in a time that is shorter than conventional method. The diagnostic method with pulse voltages enables us to use more compact and lightweight high voltage devices. In this study, we applied pulse voltages with a pulse width of about 1 ms to an artificial water tree-degraded XLPE cable and a removed XLPE cable with a class of 6.6 kV, and successfully detected current signals related to water tree degradation.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [1] Fundamental study on diagnostic method of water tree degraded XLPE cables using residual charge detection with pulse voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Kim, Myong Hwan
    Hozumi, Naohiro
    Tsuji, Taizo
    Miyajima, Kazuhisa
    Uchida, Katsumi
    IEEJ Transactions on Power and Energy, 2014, 134 (08) : 648 - 658
  • [2] Fundamental Study on Residual Charge Detection with Pulse Voltages as Diagnostic Method of Water Tree-Degraded XLPE Cables
    Kurihara, Takashi
    Okamoto, Tatsuki
    Tsuji, Taizo
    Uchida, Katsumi
    Kim, Myong Hwan
    Hozumi, Naohiro
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 84 - 87
  • [3] Assessment of charge behavior in water tree-degraded cables under pulse voltages
    Ra, Nhet
    Yamane, Ryota
    Futami, Hiroyuki
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (08) : 1126 - 1132
  • [4] Relationship between Residual Charge Signals and AC Breakdown Voltages of Removed 6.6 kV XLPE Cables Using Residual Charge Detection Method with Pulse Voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    Kim, Myong Hwan
    Hozumi, Naohiro
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 257 - 260
  • [5] Pulse Response Measurement for Locating Water Tree Degradation in XLPE Cables
    Hiei, Susumu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Uchida, Katsumi
    Tsuji, Taizo
    ELECTRICAL ENGINEERING IN JAPAN, 2012, 180 (03) : 18 - 24
  • [6] Pulse response measurement aiming for locating water tree degradation in XLPE cables
    Hiei, Susumu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Uchida, Katsumi
    Tsuji, Taizo
    IEEJ Transactions on Fundamentals and Materials, 2011, 131 (06): : 439 - 444
  • [7] FEASIBILITY STUDY ON "CHARGE RADAR" METHOD FOR DIAGNOSING WATER TREE DEGRADED XLPE CABLES WITH SPATIAL RESOLUTION
    Hiei, Susumu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Uchida, Katsumi
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 147 - 147
  • [8] Frequency domain dielectric relaxation in water tree degraded XLPE cables
    Thomas, Andrew J.
    Saha, Tapan K.
    2007 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING, VOLS 1-2, 2007, : 290 - 295
  • [9] Water migration in degraded XLPE cables
    Oyegoke, B. S.
    Birtwhistle, D.
    Lyall, J.
    Saha, T. K.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 704 - 707
  • [10] Evaluation of Relationship between Residual Charge Signal and AC Breakdown Strength of Removed XLPE Cables at 22,66 and 77 kV Classes by Detecting Residual Charge due to Water Tree Degradation with Pulse Voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    Hozumi, Naohiro
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 98 - 101