Dual-Scheimpflug-Placido-disc corneal analysis in cats

被引:2
|
作者
de Andrade Ramos, Leticia [1 ]
Seullner Brandao, Claudia Valeria [1 ]
Guillermo Arce, Carlos [2 ]
Haddad Pinho, Renata [1 ]
Garbelotti Goncalves, Lenise [1 ]
Padovani, Carlos Roberto [3 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Vet Med & Anim Sci, Dept Vet Surg & Anim Reprod, Campus Botucatu, BR-18618681 Sao Paulo, Brazil
[2] Ophthalmol Hosp & Eye Bank Sorocaba, Contact Lens Cornea Refract Surg Res & Technol Se, Sao Paulo, Brazil
[3] Sao Paulo State Univ UNESP, Biosci Inst, Dept Biostat, Sao Paulo, Brazil
关键词
corneal tomography; corneal topography; Galilei; keratometry; pachymetry; Scheimpflug; INTRAOCULAR-LENS POWER; ULTRASONIC PACHYMETRY; THICKNESS; CURVATURE; ANTERIOR; BIOMETRY; PENTACAM; ORBSCAN; GALILEI; KITTEN;
D O I
10.1111/vop.12993
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the corneal topography and tomography of cats using a dual Scheimpflug and Placido disc device. Animal studied Sixteen mixed-breed cats (32 eyes). Procedure(s) Cats were sedated using meperidine (4.3 mg/kg/IM) and xylazine (0.5 mg/kg/IM), and evaluated using the software Galilei (TM). Values assessed included anterior and posterior corneal curvature, total corneal power, and corneal thickness. Results Ten males and six females aged between 18 and 48 months were evaluated. The simulated keratometry (SimK) was 38.37 +/- 0.83D, mean posterior keratometry -4.89 +/- 0.34D, and mean total corneal power 38.04 +/- 0.94D. The mean central corneal thickness (CCT) was 617.34 +/- 53.38 mu m with a mean thinnest point of 583.74 +/- 60.60 mu m. Conclusion The Galilei (TM) examination was feasible in cats, enabling a detailed study of the cornea. To the best of our knowledge, this is the first study evaluating the corneal topography and tomography of cats using a device that integrates data from a dual Scheimpflug and Placido disc system.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [31] Precision of Corneal Aberrations Measured by a New SD-OCT/Placido Topographer and Its Agreement With a Scheimpflug/Placido Topographer
    Ning, Rui
    Niu, Lingling
    Xing, Wenqian
    Wan, Ting
    Huang, Xiaomin
    Xiahou, Jinxuan
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Wang, Xiaoying
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (06) : 405 - +
  • [32] Comparison of keratometry using SS-OCT and dual Scheimpflug-Placido imaging in postmyopic corneal refractive surgery eyes
    Khimani, Karima
    Ordonez, Adriana
    Pandit, Rahul T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (01): : 16 - 20
  • [33] Comparison of total keratometry with corneal power measured by optical low-coherence reflectometry and placido-dual Scheimpflug system
    Kommineni, Usha Bhanu
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Reddy, Jagadesh C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1496 - 1503
  • [34] Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer
    Savini, Giacomo
    Carbonelli, Michele
    Sbreglia, Alessandra
    Barboni, Piero
    Deluigi, Giulia
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09): : 1679 - 1685
  • [35] Repeatability, Reproducibility, and Agreement of Two Scheimpflug-Placido Anterior Corneal Analyzers for Posterior Corneal Surface Measurement
    Bao, Fangjun
    Savini, Giacomo
    Shu, Bao
    Zhu, Senmiao
    Gao, Rongrong
    Dang, Guanxin
    Yu, Ayong
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (08) : 524 - U114
  • [36] Higher Order Aberration Measurement Comparison Between Scheimpflug and Dual Scheimpflug/Placido Technology in Normal and Keratoconic Eyes
    Straziota, Claudia Elena Perez
    Piccinini, Andre Luis
    Golan, Oren
    Torres-Netto, Emilio Almeida
    Hafezi, Farhad
    Randleman, James Bradley
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [37] Corneal Densitometry with Galilei Dual Scheimpflug Analyzer
    Consejo, Alejandra
    Basabilbaso, Silvia
    Remon, Laura
    PHOTONICS, 2023, 10 (04)
  • [38] Agreement between a new swept-source ocular coherence tomography and a Placido disc-dual Scheimpflug ocular biometric devices
    McLintock, Cameron
    Niyazmand, Hamed
    Seo, Shiney
    Barrett, Graham
    Kumar Nilagiri, Vinay
    Karimian, Sahar
    McKelvie, James
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 905 - 911
  • [39] Comparison between corneal elevation maps using different reference surfaces with Scheimpflug–Placido topographer
    Engy Mohamed Mostafa
    International Ophthalmology, 2017, 37 : 553 - 558
  • [40] Higher-order aberration measurements: Comparison between Scheimpflug and dual Scheimpflug-Placido technology in normal eyes
    Piccinini, Andre L.
    Golan, Oren
    Hafezi, Farhad
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04): : 490 - 494