Dual-Scheimpflug-Placido-disc corneal analysis in cats

被引:2
|
作者
de Andrade Ramos, Leticia [1 ]
Seullner Brandao, Claudia Valeria [1 ]
Guillermo Arce, Carlos [2 ]
Haddad Pinho, Renata [1 ]
Garbelotti Goncalves, Lenise [1 ]
Padovani, Carlos Roberto [3 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Vet Med & Anim Sci, Dept Vet Surg & Anim Reprod, Campus Botucatu, BR-18618681 Sao Paulo, Brazil
[2] Ophthalmol Hosp & Eye Bank Sorocaba, Contact Lens Cornea Refract Surg Res & Technol Se, Sao Paulo, Brazil
[3] Sao Paulo State Univ UNESP, Biosci Inst, Dept Biostat, Sao Paulo, Brazil
关键词
corneal tomography; corneal topography; Galilei; keratometry; pachymetry; Scheimpflug; INTRAOCULAR-LENS POWER; ULTRASONIC PACHYMETRY; THICKNESS; CURVATURE; ANTERIOR; BIOMETRY; PENTACAM; ORBSCAN; GALILEI; KITTEN;
D O I
10.1111/vop.12993
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the corneal topography and tomography of cats using a dual Scheimpflug and Placido disc device. Animal studied Sixteen mixed-breed cats (32 eyes). Procedure(s) Cats were sedated using meperidine (4.3 mg/kg/IM) and xylazine (0.5 mg/kg/IM), and evaluated using the software Galilei (TM). Values assessed included anterior and posterior corneal curvature, total corneal power, and corneal thickness. Results Ten males and six females aged between 18 and 48 months were evaluated. The simulated keratometry (SimK) was 38.37 +/- 0.83D, mean posterior keratometry -4.89 +/- 0.34D, and mean total corneal power 38.04 +/- 0.94D. The mean central corneal thickness (CCT) was 617.34 +/- 53.38 mu m with a mean thinnest point of 583.74 +/- 60.60 mu m. Conclusion The Galilei (TM) examination was feasible in cats, enabling a detailed study of the cornea. To the best of our knowledge, this is the first study evaluating the corneal topography and tomography of cats using a device that integrates data from a dual Scheimpflug and Placido disc system.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [21] Best indices of dual Scheimpflug/Placido tomographer for keratoconus detection
    Heidari, Zahra
    Jafarzadehpour, Ebrahim
    Mohammadpour, Mehrdad
    Hashemi, Hassan
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (04) : 1353 - 1362
  • [22] Best indices of dual Scheimpflug/Placido tomographer for keratoconus detection
    Zahra Heidari
    Ebrahim Jafarzadehpour
    Mehrdad Mohammadpour
    Hassan Hashemi
    International Ophthalmology, 2023, 43 : 1353 - 1362
  • [23] Comparison of Corneal Higher-order Aberrations Measured by Scheimpflug Camera and Placido Disc-based Topography in Korean Patients
    Lim, Yeon Ju
    Jung, Do Hee
    Pak, Kang Yeun
    Cho, Chan-Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1141 - 1151
  • [24] Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis
    Jin, Yili
    McAlinden, Colm
    Sun, Yong
    Wen, Daizong
    Wang, Yiran
    Yu, Jinjin
    Feng, Ke
    Song, Benhao
    Wang, Qinmei
    Chen, Shihao
    Huang, Jinhai
    EYE AND VISION, 2021, 8 (01)
  • [25] Comparison of Anterior Segment Measurements With a Dual Scheimpflug Placido Corneal Topographer and a New Partial Coherence Interferometer in Keratoconic Eyes
    Yagci, Ramazan
    Kulak, Ali Ender
    Guler, Emre
    Tenlik, Aylin
    Guragac, Fatma Betul
    Hepsen, Ibrahim Feyzi
    CORNEA, 2015, 34 (09) : 1012 - 1018
  • [26] Impact of botulinum toxin-A on corneal curvature assessed with Scheimpflug and Placido systems
    Osaki, Teissy
    Osaki, Midori H.
    Osaki, Tammy H.
    Hirai, Flavio E.
    Nallasamy, Nambi
    Campos, Mauro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05): : 750 - 758
  • [27] Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug-Placido system
    Cervino, Alejandro
    Dominguez-Vicent, Alberto
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 186 - 192
  • [28] Clinical Comparison of Corneal Topography Using a Combined Scheimpflug and Placido (Galilei) and a Scheimpflug Device (Pentacam) in Keratoconus Eyes
    Tappeiner, C.
    Eschmann, R.
    Schuerch, K.
    Frueh, B. E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [29] Agreement and repeatability of corneal tomography in healthy eyes using a new swept-source OCT, a rotating Scheimpflug camera, and a dual Scheimpflug-Placido system
    Herber, Robert
    Lenk, Janine
    Pillunat, Lutz E.
    Raiskup, Frederik
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 190 - 198
  • [30] Preliminary results of a computerized Placido disc surgical corneal topographer
    Carvalho, LA
    Tonissi, SA
    Castro, JC
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 53 - 62