Dual-Scheimpflug-Placido-disc corneal analysis in cats

被引:2
|
作者
de Andrade Ramos, Leticia [1 ]
Seullner Brandao, Claudia Valeria [1 ]
Guillermo Arce, Carlos [2 ]
Haddad Pinho, Renata [1 ]
Garbelotti Goncalves, Lenise [1 ]
Padovani, Carlos Roberto [3 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Vet Med & Anim Sci, Dept Vet Surg & Anim Reprod, Campus Botucatu, BR-18618681 Sao Paulo, Brazil
[2] Ophthalmol Hosp & Eye Bank Sorocaba, Contact Lens Cornea Refract Surg Res & Technol Se, Sao Paulo, Brazil
[3] Sao Paulo State Univ UNESP, Biosci Inst, Dept Biostat, Sao Paulo, Brazil
关键词
corneal tomography; corneal topography; Galilei; keratometry; pachymetry; Scheimpflug; INTRAOCULAR-LENS POWER; ULTRASONIC PACHYMETRY; THICKNESS; CURVATURE; ANTERIOR; BIOMETRY; PENTACAM; ORBSCAN; GALILEI; KITTEN;
D O I
10.1111/vop.12993
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the corneal topography and tomography of cats using a dual Scheimpflug and Placido disc device. Animal studied Sixteen mixed-breed cats (32 eyes). Procedure(s) Cats were sedated using meperidine (4.3 mg/kg/IM) and xylazine (0.5 mg/kg/IM), and evaluated using the software Galilei (TM). Values assessed included anterior and posterior corneal curvature, total corneal power, and corneal thickness. Results Ten males and six females aged between 18 and 48 months were evaluated. The simulated keratometry (SimK) was 38.37 +/- 0.83D, mean posterior keratometry -4.89 +/- 0.34D, and mean total corneal power 38.04 +/- 0.94D. The mean central corneal thickness (CCT) was 617.34 +/- 53.38 mu m with a mean thinnest point of 583.74 +/- 60.60 mu m. Conclusion The Galilei (TM) examination was feasible in cats, enabling a detailed study of the cornea. To the best of our knowledge, this is the first study evaluating the corneal topography and tomography of cats using a device that integrates data from a dual Scheimpflug and Placido disc system.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [1] Repeatability and Reliability of a Combined Dual-Scheimpflug Placido Disc Corneal Topographer in Eyes with Keratoconus
    Poulsen, Anne
    Jang, Diane
    Khan, Mahmood
    Al-Mohtaseb, Zaina Nabil
    Chen, Michael
    O'Rourke, Tara
    Williams, Donald
    Banerjee, Kalins
    Zhan, Xiang
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [2] Descriptive analysis of corneal maps and anterior segment tomography of the rabbit eye using dual Scheimpflug and Placido Disc tomography
    Ramos, Leticia de Andrade
    Arce, Carlos Guillermo
    Brandao, Claudia Valeria Seullner
    Goncalves, Lenise Garbelotti
    Padovani, Carlos Roberto
    CIENCIA RURAL, 2025, 55 (06):
  • [3] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Lou, Wei
    Du, Wei
    Jin, Haiying
    Hu, Ying
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [4] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Wei Lou
    Wei Du
    Haiying Jin
    Ying Hu
    BMC Ophthalmology, 22
  • [5] Repeatability of corneal power and wavefront aberration measurements with a dual-Scheimpflug Placido corneal topographer
    Wang, Li
    Shirayama, Mariko
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03): : 425 - 430
  • [6] Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis
    De Stefano, Vinicius Silbiger
    Soares Melo Junior, Luiz Alberto
    Mallmann, Felipe
    Schor, Paulo
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2010, 73 (04) : 363 - 366
  • [7] Comparison of Scheimpflug tomography, Placido disc, and combined Placido Scheimpflug in the measurement of pupil offset in myopic population
    Ning, Jiliang
    Zhang, Lijun
    FRONTIERS IN MEDICINE, 2024, 11
  • [8] Repeatability and Agreement of Horizontal Corneal Diameter Measurements Between Scanning-Slit Topography, Dual Rotating Scheimpflug Camera With Placido Disc Tomography, Placido Disc Topography, and Optical Coherence Tomography
    Namkung, Soobin
    Boyle, Alexander Buckenham
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    CORNEA, 2022, 41 (11) : 1392 - 1397
  • [9] Repeatability of posterior and total corneal curvature measurements with a dual Scheimpflug-Placido tomographer
    Kim, Eric J.
    de Oca, Ildamaris Montes
    Wang, Li
    Weikert, Mitchell P.
    Koch, Douglas D.
    Khandelwal, Sumitra S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12): : 2731 - 2738
  • [10] Corneal higher-order aberrations measurements: Comparison between Scheimpflug and dual Scheimpflug-Placido technology in keratoconic eyes
    Piccinini, Andre L.
    Golan, Oren
    Torres-Netto, Emilio A.
    Hafezi, Farhad
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (07): : 985 - 991