EVALUATION OF SKIN DOSE UNDER THE BOLUS FOR POST-OPERATIVE BREAST CANCER TREATMENT

被引:0
作者
Laurikaitiene, J. [1 ,2 ,4 ]
Tzirkalov, T. [3 ]
Dimitrova, T. L. [3 ]
Laurikaitis, M. [1 ,5 ]
机构
[1] Hosp Lithuanian Univ Hlth Sci Kaunas Clin, Oncol Hosp, Kaunas, Lithuania
[2] Aleksandras Stulginskis Univ, Kaunas, Lithuania
[3] Plovdiv Univ Paisii Hilendarski, Plovidv, Bulgaria
[4] Kaunas Univ Technol, Kaunas, Lithuania
[5] JSC Med Fiz, Kaunas, Lithuania
来源
MEDICAL PHYSICS IN THE BALTIC STATES | 2017年
关键词
radiotherapy; post-operative breast cancer irradiation; bolus; air gaps; FILM; RADIOTHERAPY;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Results of investigation of the absorbed doses on a phantom surface under the "sticking" and ordinary non-sticking silicone boluses simulating post-operative breast cancer irradiation are presented in this paper. It is shown that the treatment effectiveness in post-operative breast cancer irradiation may be improved when a "sticking" bolus attached to the patient surface is applied instead of an ordinary non-sticking bolus. Application of "sticking" bolus adapted treatment configuration is of advantage because it is independent on air gaps between bolus and the surface.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 11 条
  • [1] [Anonymous], 2014, KHANS PHYS RAD THERA
  • [2] Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy
    Butson, MJ
    Cheung, T
    Yu, P
    Metcalfe, P
    [J]. RADIATION MEASUREMENTS, 2000, 32 (03) : 201 - 204
  • [3] Capintec Inc., CT HEAD BOD DOS PAHN
  • [4] Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters
    Hsu, Shu-Hui
    Kulasekere, Ravi
    Roberson, Peter L.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 222 - 237
  • [5] Kassaee A, 2000, Med Dosim, V25, P127
  • [6] Khan Y., 2013, Journal of Cancer Therapy, V04, P5, DOI [10.4236/jct.2013.47147, DOI 10.4236/JCT.2013.47147]
  • [7] Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams
    Martisikova, Maria
    Ackermann, Benjamin
    Jaekel, Oliver
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24) : 7013 - 7027
  • [8] POINTON R, 1991, RADIOTHERAPY MALIGNA
  • [9] The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner
    Sim, G. S.
    Wong, J. H. D.
    Ng, K. H.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 85 - 95
  • [10] The influence of the bolus-surface distance on the dose distribution in the build-up region
    Sroka, Martyna
    Regula, Jakub
    Lobodziec, Wlodzimierz