Transjugular approach to transseptal balloon mitral valvuloplasty

被引:0
作者
Joseph, G
Baruah, DK
Kuruttukulam, SV
Chandy, ST
Krishnaswami, S
机构
[1] Department of Cardiology, Christian Medical College Hospital, Vellore
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1997年 / 42卷 / 02期
关键词
mitral valve stenosis; balloon dilation; heart catheterization; heart septum; jugular veins;
D O I
10.1002/(SICI)1097-0304(199710)42:2<219::AID-CCD30>3.0.CO;2-G
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The feasibility of a transjugular approach to septal puncture and Inoue-balloon mitral valvuloplasty (BMV) was studied in 20 patients with severe mitral stenosis and varying degrees of anatomic atrial distortion, Left atrial entry by transjugular septal puncture was achieved without difficulty and BMV completed in all patients. In all of 16 patients who had high septal punctures, crossing the mitral valve with the Inoue-balloon was consistently simple and quick, In one patient, septal dilation after very high septal puncture led to a tear extending to the atrial free wall, resulting in cardiac tamponade requiring surgery. Another patient developed severe mitral regurgitation after BMV and required mitral valve replacement. Excellent results were obtained in 16 patients, The transjugular approach simplifies BMV procedure significantly in patients with distorted atrial anatomy and allows rapid patient mobilization. Its safety and efficacy need to be established in larger studies. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 19 条
  • [1] BALLOON MITRAL VALVOTOMY BY USING THE TWIN-AT CATHETER - IMMEDIATE RESULTS AND COMPLICATIONS IN 110 PATIENTS
    BERLAND, J
    ROCHA, P
    CHOUSSAT, A
    LEFEBVRE, T
    FERNANDEZ, F
    RATH, P
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (02): : 126 - 133
  • [2] COMPARISON OF HEMODYNAMIC-RESULTS OF ANTEROGRADE VERSUS RETROGRADE PERCUTANEOUS BALLOON AORTIC VALVULOPLASTY
    BLOCK, PC
    PALACIOS, IF
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (08) : 659 - 662
  • [3] LONG-TERM RESULTS OF PERCUTANEOUS MITRAL VALVULOPLASTY WITH THE INOUE BALLOON CATHETER
    CHEN, CR
    CHENG, TO
    CHEN, JY
    ZHOU, YL
    MEI, J
    MA, TZ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (18) : 1445 - 1448
  • [4] TRANSSEPTAL CATHETERIZATION UPDATE 1992
    CLUGSTON, R
    LAU, FYK
    RUIZ, C
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (04): : 266 - 274
  • [5] MODIFIED TECHNIQUE OF TRANS-SEPTAL LEFT HEART CATHETERIZATION
    CROFT, CH
    LIPSCOMB, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (04) : 904 - 910
  • [6] EFFECT OF BALLOON SIZE AND STEPWISE INFLATION TECHNIQUE ON THE ACUTE RESULTS OF INOUE MITRAL COMMISSUROTOMY
    FELDMAN, T
    CARROLL, JD
    HERRMANN, HC
    HOLMES, DR
    BASHORE, TM
    ISNER, JM
    DORROS, G
    TOBIS, JM
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (03): : 199 - 205
  • [7] HATLE L, 1985, DOPPLER ULTRASOUND C, P118
  • [8] COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES
    HELMCKE, F
    NANDA, NC
    HSIUNG, MC
    SOTO, B
    ADEY, CK
    GOYAL, RG
    GATEWOOD, RP
    [J]. CIRCULATION, 1987, 75 (01) : 175 - 183
  • [9] Hung JS, 1996, CATHETER CARDIO DIAG, V37, P188, DOI 10.1002/(SICI)1097-0304(199602)37:2<188::AID-CCD19>3.0.CO
  • [10] 2-G