Percutaneous CT-guided cutting needle biopsy of pulmonary lesions. Retrospective analysis of 153 procedures

被引:4
|
作者
Besa, Cecilia [1 ]
Huete, Alvaro [1 ]
Baechler, Pablo [1 ,2 ]
Cruz, Francisco [1 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Radiol, Fac Med, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Ctr Imagenes Biomed, Santiago, Chile
关键词
Biopsy; needle; Lung neoplasms; Pneumothorax; Tomography; emission-computed; DIAGNOSTIC-ACCURACY; LUNG-BIOPSY; ASPIRATION; COMPLICATIONS;
D O I
10.4067/S0034-98872013000400005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT guided percutaneous biopsy of pulmonary lesions is a widely used technique. Aim: To evaluate the yield and complication rate of CT-guided percutaneous core biopsy of pulmonary lesions. Material and Methods: A retrospective study of 153 consecutive lung biopsies performed in a 7-year period was undertaken. Patients and lesions characteristics were reviewed. The yield for the diagnosis of malignant and benign lesions and the complication rate were calculated. Lesion size and depth from the pleural surface were analyzed as potential predictive variables for occurrence of a false-negative diagnosis of malignancy. The final diagnosis was established by surgical biopsy of the lesion or clinical and imaging follow up. Results: The mean age of patients was 66 +/- 14 years and 55% were male. The final diagnosis of the lesion was malignant in 139 and benign in 14 cases (prevalence of malignancy 90.8%). For the diagnosis of malignancy, the overall yield of the biopsy was 91.5% with a sensitivity of 90.6%. A specific diagnosis of benign lesions was obtained in 5 out of 14 biopsies (35%). We did not identify an association between the lesion size or depth and the rate of false-negative diagnosis of malignancy. The pneumothorax rate was 13.7% (n = 21) and eight (38%) required drainage. The average lesion depth of patients that had a pneumothorax was significant greater than the cases without the complication. No major bleeding complications occurred. Conclusions: Percutaneous CT-guided cutting needle biopsies of pulmonary lesions have an excellent diagnostic accuracy for malignant pulmonary lesions, at a low complication rate.
引用
收藏
页码:449 / 456
页数:8
相关论文
共 50 条
  • [1] CT-guided percutaneous fine-needle aspiration biopsy of pulmonary lesions. A descriptive study
    Bakhshayeshkaram, M
    Zahirifard, S
    Tahbaz, M
    Kaynama, K
    Masjedi, M
    LUNG CANCER, 2005, 49 : S208 - S208
  • [2] Re: CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions. A reply
    Li, Y.
    Du, Y.
    Yang, H. F.
    Yu, J. H.
    Xu, X. X.
    CLINICAL RADIOLOGY, 2013, 68 (06) : E354 - E354
  • [3] Feasibility and accuracy of CT-guided percutaneous needle biopsy of cavitary pulmonary lesions
    Kiranantawat, Nantaka
    Petranovic, Milena
    McDermott, Shaunagh
    Gilman, Matthew
    Digumarthy, Subba R.
    Shepard, Jo-Anne O.
    Sharma, Amita
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (06) : 435 - 441
  • [4] CT-guided transthoracic needle biopsy of pulmonary lesions: comparison between the cutting needle and aspiration needle
    Huang, Zhen-Guo
    Sun, Hong-Liang
    Wang, Cun-Li
    Gao, Bao-Xiang
    Chen, He
    Yang, Min-Xing
    Chen, Xiao-Liang
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118):
  • [5] CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions
    Li, Y.
    Du, Y.
    Yang, H. F.
    Yu, J. H.
    Xu, X. X.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E43 - E48
  • [6] CT-guided core biopsy for retroperitoneal lesions. Experience in 136 procedures
    Lagos C, Claudio
    Gallardo, Eduardo
    Huete, Alvaro
    REVISTA MEDICA DE CHILE, 2019, 147 (10) : 1266 - 1272
  • [7] Percutaneous CT-guided multisampling core needle biopsy of thoracic lesions
    Loubeyre, P
    Copercini, M
    Dietrich, PY
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (05) : 1294 - 1298
  • [8] Re: CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions
    Guimaraes, M. D.
    Marchiori, E.
    CLINICAL RADIOLOGY, 2013, 68 (06) : E353 - E353
  • [9] Diagnostic accuracy and complication rates of percutaneous CT-guided coaxial needle biopsy of pulmonary lesions
    Sarajlic, Vesna
    Vesnic, Sanela
    Udovicic-Gagula, Dalma
    Kuric, Haris
    Akhan, Okan
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (04) : 553 - 557
  • [10] The diagnostic accuracy of CT-guided percutaneous core needle biopsy and fine needle aspiration in pulmonary lesions: a meta-analysis
    Zhang, H. -F.
    Zeng, X. -T.
    Xing, F.
    Fan, N.
    Liao, M. -Y.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E1 - E10