Levels of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls in human milk from different regions of France

被引:30
作者
Focant, Jean-Francois [1 ]
Frery, Nadine [2 ]
Bidondo, Marie-Laure [2 ]
Eppe, Gauthier [1 ]
Scholl, Georges [1 ]
Saoudi, Abdessattar [2 ]
Oleko, Amivi [2 ]
Vandentorren, Stephanie [2 ]
机构
[1] Univ Liege, Dept Chem, CART Mass Spectrometry Lab, B-4000 Liege, Belgium
[2] Natl Inst Publ Hlth Surveillance InVS, St Maurice, France
关键词
Polychlorinated dibenzo-p-dioxins (PCDDs); Polychlorinated dibenzofurans (PCDFs); Polychlorinated biphenyls (PCBs); Human milk; Intake; Time trend; TOXIC EQUIVALENCY FACTORS; BREAST-MILK; EXPOSURE; PCBS; FURANS; PCDDS; PCDFS; CONTAMINANTS; POLLUTANTS; CLEANUP;
D O I
10.1016/j.scitotenv.2013.02.057
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We report on the pilot study carried out before the start of the Elfe project (French longitudinal study from childhood). A total of 44 samples of mature human milk were collected at home 8 weeks after delivery. A total of 7 polychlorinated dibenzo-p-dioxins (PCDDs), 10 polychlorinated dibenzofurans (PCDFs), 12 dioxin-like (DL) polychlorinated biphenyls (PCBs), and 6 non dioxin-like (NDL)-PCBs were measured. For total TEQ (PCDD/Fs and DL-PCBs), the geometric mean concentration was 17.81 pg TEQ(WHO05)/g lipids. Relative PCDD, PCDF, and DL-PCB contributions to the arithmetic mean TEQ(WHO05) were 38%, 18%, and 44%, respectively. The use of TEFWHO05 instead of TEFWHO98 resulted in a 27% reduction of the total TEQ value. Although PCDD levels did not significantly change (less than 0.5% increase), PCDF and DL-PCB levels both decreased by 35% and 38%, respectively. Levels have been compared to data obtained during a previous non-reported national study conducted in 1998 (TEFWHO98) in French lactaria (n = 244). The mean of PCDD/Fs has decreased about 39.4% (18.8 pg TEQ(WHO98)/g lipids in 1998 vs 11.4 pg TEQ(WHO98)/g lipids in pilot study), respectively 41.5% for PCDDs (10.6 pg TEQ(WHO98)/g lipids in 1998 vs 6.2 pg TEQ(WHO98)/g lipids in pilot study) and 36.7% for PCDFs (7.9 pg TEQ(WHO98)/g lipids in 1998 vs 5.0 pg TEQ(WHO98)/g lipids in pilot study). For the sum of the 6 NDL-PCBs, the 2007 geometric mean concentration in milk was 176.3 ng/g lipids. The arithmetic mean lipid concentration in 2007 breast milk was 26.4 g/l (range from 6.0 to 46.7 g/l). A PCDD/F and DL-PCB daily intake was estimated to be 62.3 pg TEQ(WHO05)/kg body weight per day (85.0 pg TEQ(WHO98)/kg body weight per day) for a baby of 5 kg of body weight fed daily with 700 ml of maternal milk containing 25 g/l of lipids. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 56 条
[41]   Monitoring dioxins and furans in a population living near a hazardous waste incinerator: levels in breast milk [J].
Schuhmacher, M ;
Domingo, JL ;
Kiviranta, H ;
Vartiainen, T .
CHEMOSPHERE, 2004, 57 (01) :43-49
[42]  
Scientific Committee on Food, 2001, REPORT CS CNTM DIOXI
[43]  
SIM MR, 1992, AM J EPIDEMIOL, V136, P1
[44]   Dietary exposure to polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls of the French population: Results of the second French Total Diet Study [J].
Sirot, Veronique ;
Tard, Alexandra ;
Venisseau, Anais ;
Brosseaud, Aline ;
Marchand, Philippe ;
Le Bizec, Bruno ;
Leblanc, Jean-Charles .
CHEMOSPHERE, 2012, 88 (04) :492-500
[45]   Dioxin concentration in human milk in Hebei province in China and Tokyo, Japan: Potential dietary risk factors and determination of possible sources [J].
Sun, SJ ;
Zhao, JH ;
Liu, HJ ;
Liu, DW ;
Ma, YX ;
Li, L ;
Horiguchi, H ;
Uno, H ;
Iida, T ;
Koga, M ;
Kiyonari, Y ;
Nakamura, M ;
Sasaki, S ;
Fukatu, H ;
Clark, GC ;
Kayama, F .
CHEMOSPHERE, 2006, 62 (11) :1879-1888
[46]   Ratio variation of congener profiles of PCDD/Fs and dioxin-like PCBs in human milk during lactation [J].
Takekuma, Mikiko ;
Saito, Koichi ;
Falandysz, Jerzy ;
Nakazawa, Hiroyuki .
SCIENCE OF THE TOTAL ENVIRONMENT, 2011, 409 (08) :1368-1377
[47]   Dioxins, furans and dioxin-like PCBs: Occurrence in food and dietary intake in France [J].
Tard, A. ;
Gallotti, S. ;
Leblanc, J.-C. ;
Volatier, J.-L. .
FOOD ADDITIVES AND CONTAMINANTS, 2007, 24 (09) :1007-1017
[48]   PCDD/Fs and dioxin-like PCBs in human milk and estimation of infants' daily intake: A review [J].
Ulaszewska, Maria Malgorzata ;
Zuccato, Ettore ;
Davoli, Enrico .
CHEMOSPHERE, 2011, 83 (06) :774-782
[49]   Toxic equivalency factors (TEFs) for PCBs, PCDDs, PCDFs for humans and wildlife [J].
Van den Berg, M ;
Birnbaum, L ;
Bosveld, ATC ;
Brunström, B ;
Cook, P ;
Feeley, M ;
Giesy, JP ;
Hanberg, A ;
Hasegawa, R ;
Kennedy, SW ;
Kubiak, T ;
Larsen, JC ;
van Leeuwen, FXR ;
Liem, AKD ;
Nolt, C ;
Peterson, RE ;
Poellinger, L ;
Safe, S ;
Schrenk, D ;
Tillitt, D ;
Tysklind, M ;
Younes, M ;
Waern, F ;
Zacharewski, T .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1998, 106 (12) :775-792
[50]   The 2005 World Health Organization reevaluation of human and mammalian toxic equivalency factors for dioxins and dioxin-like compounds [J].
Van den Berg, Martin ;
Birnbaum, Linda S. ;
Denison, Michael ;
De Vito, Mike ;
Farland, William ;
Feeley, Mark ;
Fiedler, Heidelore ;
Hakansson, Helen ;
Hanberg, Annika ;
Haws, Laurie ;
Rose, Martin ;
Safe, Stephen ;
Schrenk, Dieter ;
Tohyama, Chiharu ;
Tritscher, Angelika ;
Tuomisto, Jouko ;
Tysklind, Mats ;
Walker, Nigel ;
Peterson, Richard E. .
TOXICOLOGICAL SCIENCES, 2006, 93 (02) :223-241