Ultrasonic extraction combined with fast furnace analysis as an improved methodology for total selenium determination in seafood by electrothermal-atomic absorption spectrometry

被引:38
作者
Méndez, H [1 ]
Alava, F [1 ]
Lavilla, I [1 ]
Bendicho, C [1 ]
机构
[1] Univ Vigo, Fac Ciencias Quim, Dept Quim Anal & Alimentaria, Vigo 36200, Spain
关键词
ultrasonic extraction; seafood; selenium; electrothermal-AAS;
D O I
10.1016/S0003-2670(01)01475-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on the analytical minimalism concept outlined by Halls [J. Anal. Atomic Spectromet. 10(1995) 169], a fast methodology for determination of Se in seafood by electrothermal-atomic absorption spectrometry (ETAAS) is proposed. The following features are considered in order to meet with such a concept: (i) rapid sample preparation based on accelerated extraction of Se by means of ultrasounds (ii) shortening of the thermal program by omission of the pyrolysis stage; (iii) use of simple aqueous standards for calibration. Addition of a Pd matrix modifier was seen to be needed for quantitative recovery of Se. The method was validated against two certified reference materials and subsequently applied to determination of Se in six seafood samples. Contents ranged from 1 to 3 mug g(-1). The limit of detection was 0.16 mug g(-1) and the precision, expressed as relative standard deviation, was in the range 3-12%. Re-adsorption of Se was seen to be a source of error which could be overcome by working with low-acidity media. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 23 条
[1]   Ultrasound-assisted extraction of lead from solid samples: a new perspective on the slurry-based sample preparation methods for electrothermal atomic absorption spectrometry [J].
Amoedo, L ;
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1221-1226
[2]   Experimental design .1. Screening [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (01) :26-31
[3]   Ultrasonic extraction and field-portable anodic stripping voltammetry of lead from environmental samples [J].
Ashley, K .
ELECTROANALYSIS, 1995, 7 (12) :1189-1192
[4]  
BENDICHO C, 1993, ATOM SPECTROSC, V14, P187
[5]  
BENDICHO C, 2000, ENCY SEPARATION SCI, V9, P4421
[6]  
Cabrera C, 1995, J AOAC INT, V78, P1061
[7]   Solid-liquid extraction of copper from slurried samples using high intensity probe sonication for electrothermal atomic absorption spectrometry [J].
Capelo, JL ;
Filgueiras, AV ;
Lavilla, I ;
Bendicho, C .
TALANTA, 1999, 50 (04) :905-911
[8]   Ultrasound-assisted extraction of cadmium from slurried biological samples for electrothermal atomic absorption spectrometry [J].
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1285-1290
[9]   Enzymatic digestion-high-pressure homogenization prior to slurry introduction graphite furnace atomic absorption spectrometry for selenium determination in plant and animal tissues [J].
Chen, X ;
Marshall, WD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (09) :3727-3732
[10]   Determination of selenium in meat products by hydride generation atomic absorption spectrometry-selenium levels in meat, organ meats, and sausages in Spain [J].
DiazAlarcon, JP ;
NavarroAlarcon, M ;
delaSerrana, HLG ;
LopezMartinez, MC .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (06) :1494-1497