Sensing Devices and Sensor Signal Processing for Remote Monitoring of Vital Signs in CHF Patients

被引:104
作者
Fanucci, Luca [1 ,2 ]
Saponara, Sergio [1 ,2 ]
Bacchillone, Tony [1 ,2 ]
Donati, Massimiliano [1 ,2 ]
Barba, Pierluigi [3 ]
Sanchez-Tato, Isabel [4 ]
Carmona, Cristina [4 ]
机构
[1] Univ Pisa, I-56125 Pisa, Italy
[2] Consorzio Pisa Ric, I-56125 Pisa, Italy
[3] CAEN Spa, I-55049 Viareggio, Italy
[4] Fdn CITIC, ES-29590 Malaga, Spain
关键词
Biomedical instrumentation; chronic heart failure (CHF); e-health; sensor signal processing; telemonitoring; vital signs sensors; HEART-FAILURE; ATRIAL-FIBRILLATION; SYSTEM; ARCHITECTURE; CARE;
D O I
10.1109/TIM.2012.2218681
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, chronic heart failure (CHF) affects an ever-growing segment of population, and it is among the major causes of hospitalization for elderly citizens. The actual out-of-hospital treatment model, based on periodic visits, has a low capability to detect signs of destabilization and leads to a high re-hospitalization rate. To this aim, in this paper, a complete and integrated Information and Communication Technology system is described enabling the CHF patients to daily collect vital signs at home and automatically send them to the Hospital Information System, allowing the physicians to monitor their patients at distance and take timely actions in case of necessity. A minimum set of vital parameters has been identified, consisting of electrocardiogram, SpO2, blood pressure, and weight, measured through a pool of wireless, non-invasive biomedical sensors. A multi-channel front-end IC for cardiac sensor interfacing has been also developed. Sensor data acquisition and signal processing are in charge of an additional device, the home gateway. All signals are processed upon acquisition in order to assert if both punctual values and extracted trends lay in a safety zone established by thresholds. Per-patient personalized thresholds, required measurements and transmission policy are allowed. As proved by first medical tests, the proposed telemedicine platform represents a valid support to early detect the alterations in vital signs that precede the acute syndromes, allowing early home interventions thus reducing the number of subsequent hospitalizations.
引用
收藏
页码:553 / 569
页数:17
相关论文
共 57 条
[51]  
van den Broek G, 2010, AMBIENT ASSISTED LIV
[52]   Wearable and Mobile System to Manage Remotely Heart Failure [J].
Villalba, E. ;
Salvi, D. ;
Ottaviano, M. ;
Peinado, I. ;
Arredondo, M. T. ;
Akay, A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (06) :990-996
[53]   A wearable point-of-care system for home use that incorporates plug-and-play and wireless standards [J].
Yao, JC ;
Schmitz, R ;
Warren, S .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2005, 9 (03) :363-371
[54]   A 60 μW 60 nV/√Hz readout front-end for portable biopotential acquisition systems [J].
Yazicioglu, Refet Firat ;
Merken, Patrick ;
Puers, Robert ;
Van Hoof, Chris .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (05) :1100-1110
[55]   A 30 μW Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring [J].
Yazicioglu, Refet Firat ;
Kim, Sunyoung ;
Torfs, Tom ;
Kim, Hyejung ;
Van Hoof, Chris .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2011, 46 (01) :209-223
[56]   Interoperability of Medical Device Information and the Clinical Applications: An HL7 RMIM based on the ISO/IEEE 11073 DIM [J].
Yuksel, Mustafa ;
Dogac, Asuman .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04) :557-566
[57]   Heart failure burden and therapy [J].
Zannad, Faiez ;
Agrinier, Nelly ;
Alla, Francois .
EUROPACE, 2009, 11 :1-9