The goal of the work was to establish the toxicity and biodistribution of the superparamagnetic protein cationized ferritin (CF) after intravenous injection. Intravenously injected CF has been used to target the extracellular matrix with high specificity in the kidney glomerulus, allowing measurements of individual glomeruli using T2*-weighted MRI. For the routine use of CF as an extracellular matrix-specific tracer, it is important to determine whether CF is toxic. In this work, we investigated the renal and hepatic toxicity, leukocyte count, and clearance of intravenously injected CF. Furthermore, we studied CF labeling in several organs using MRI and immunohistochemistry. Serum measurements of biomarkers suggest that intravenous injection of CF is neither nephrotoxic nor hepatotoxic and does not increase leukocyte counts in healthy rats at a dose of 5.75 mg/100 g. In addition to known glomerular labeling, confocal and MRI suggest that intravenously injected CF labels the extracellular matrix of the hepatic sinusoid, extracellular glycocalyx of alveolar endothelial cells, and macrophages in the spleen. Liver T2* values suggest that CF is cleared by 7 days after injection. These results suggest that CF may serve as a useful contrast agent for detection of a number of structures and functions with minimal toxicity. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:853 / 861
页数:9
相关论文
共 15 条
  • [1] Short term biodistribution and in vivo toxicity assessment of intravenously injected pristine graphene oxide nanoflakes in SD rats
    De, Indranil
    Singh, Rashmika
    Kumar, Sushil
    Singh, Srishti
    Singh, Manohar
    Panda, Jiban Jyoti
    Ghosh, Kaushik
    Mishra, Durga Prasad
    Singh, Manish
    TOXICOLOGY RESEARCH, 2024, 13 (02)
  • [2] In vivo toxicity and biodistribution of intravenously administered antibiotic-functionalized gold nanoparticles
    Rashmi Kanugodu Pradeepa
    Darshini Shivamogga Vasappa
    Srinivas Mohan
    Manjunatha Bukkambudhi Mutalik
    Anil Kumar Honnali Krishnaswamy
    Mukunda Srinivasalu
    Vidya Shimoga Suryanarayana
    Gold Bulletin, 2023, 56 : 209 - 220
  • [3] In vivo toxicity and biodistribution of intravenously administered antibiotic-functionalized gold nanoparticles
    Vasappa, Rashmi Kanugodu
    Mohan, Darshini Shivamogga
    Mutalik, Srinivas
    Krishnaswamy, Manjunatha Bukkambudhi
    Srinivasalu, Anil Kumar Honnali
    Suryanarayana, Mukunda
    Muddappa, Vidya Shimoga
    GOLD BULLETIN, 2023, 56 (04) : 209 - 220
  • [4] Acute toxicity and in vivo biodistribution of monodispersed mesoporous bioactive glass spheres in intravenously exposed mice
    Mao, Cong
    Chen, Xiaofeng
    Hu, Qing
    Miao, Guohou
    Lin, Cai
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 682 - 691
  • [5] Detection of neural connections with ex vivo MRI using a ferritin-encoding trans-synaptic virus
    Zheng, Ning
    Su, Peng
    Liu, Yue
    Wang, Huadong
    Nie, Binbin
    Fang, Xiaohui
    Xu, Yue
    Lin, Kunzhang
    Lv, Pei
    He, Xiaobin
    Guo, Yi
    Shan, Baoci
    Manyande, Anne
    Wang, Jie
    Xu, Fuqiang
    NEUROIMAGE, 2019, 197 : 133 - 142
  • [6] Iron(III)-Quercetin Complex: In Vivo Acute Toxicity and Biodistribution of Novel MRI Agent
    Innuan, Phattarawadee
    Kongkarnka, Sarawut
    Thongtharb, Atigan
    Kantapan, Jiraporn
    Dechsupa, Nathupakorn
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2025, 20 : 1303 - 1320
  • [7] In vivo and ex vivo MRI detection of localized and disseminated neural stem cell grafts in the mouse brain
    Magnitsky, S
    Watson, DJ
    Walton, RM
    Pickup, S
    Bulte, JWM
    Wolfe, JH
    Poptani, H
    NEUROIMAGE, 2005, 26 (03) : 744 - 754
  • [8] Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI
    Madabhushi, A
    Feldman, MD
    Metaxas, DN
    Tomaszeweski, J
    Chute, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (12) : 1611 - 1625
  • [9] Detection of fluorine labeled Herceptin using cellular 19F MRI ex vivo
    Bartusik, Dorota
    Tomanek, Boguslaw
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (04) : 894 - 900
  • [10] Multimodal image registration of ex vivo 4 Tesla MRI with whole mount histology for prostate cancer detection
    Chappelow, Jonathan
    Madabhushi, Anant
    Rosen, Mark
    Tomaszeweski, John
    Feldman, Michael
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512