Self-tonometry as a complement in the investigation of glaucoma patients

被引:38
作者
Chen, Enping [1 ,2 ]
Querat, Laurence [1 ]
Akerstedt, Christina [1 ]
机构
[1] St Erik Eye Hosp, Dept Anterior Segment Disorders Glaucoma Neuro Op, Clin 1, SE-11232 Stockholm, Sweden
[2] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
关键词
circadian rhythm of IOP; intraocular pressure; rebound tonometry; self-tonometry; GOLDMANN APPLANATION TONOMETRY; INDEPENDENT RISK-FACTOR; INTRAOCULAR-PRESSURE; CLINICAL-EVALUATION; ICARE; PROGRESSION; HEALTHY;
D O I
10.1111/aos.13129
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the reliability of intraocular pressure measured by patients with glaucoma themselves using a new hand-held tonometer and to observe whether the intraocular pressure (IOP) variations have the same pattern on different days while glaucoma treatment is constant. MethodsEighty-seven patients diagnosed with open-angle glaucoma or ocular hypertension were recruited to the study. Intraocular pressure measured using Goldmann applanation tonometry (GAT) was compared with IOP measured using tonometry at baseline and on the second visit. Patients measured their IOP at home using the hand-held tonometers. ResultsThe mean difference between GAT and iCare((R)) values varies from 0 to 1mmHg. Seventy-eight per cent of iCare((R)) measurements were within 3mmHg of the GAT measurements. Approximately 64% of the study eyes had higher IOP in the morning than in the afternoon/evening. Circadian patterns differed between consecutive days in 47% of the study eyes. There were IOP peaks outside office hours in up to 16% of the study eyes. ConclusionMeasurements made using rebound self-tonometry are accurate and could be used to complement the investigation of patients with glaucoma. Intraocular pressure curves provide valuable data usable when adapting glaucoma treatment.
引用
收藏
页码:788 / 792
页数:5
相关论文
共 25 条
[1]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[2]   Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma [J].
Barkana, Yaniv ;
Anis, Sarah ;
Liebmann, Jeffrey ;
Tello, Celso ;
Ritch, Robert .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) :793-797
[3]   Does Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes? [J].
Beasley, Ian G. ;
Laughton, Deborah S. ;
Coldrick, Benjamin J. ;
Drew, Thomas E. ;
Sallah, Marium ;
Davies, Leon N. .
JOURNAL OF OPHTHALMOLOGY, 2013, 2013
[4]   Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension [J].
Bengtsson, B ;
Heijl, A .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (06) :513-518
[5]   Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients [J].
Brusini, P ;
Salvetat, ML ;
Zeppieri, M ;
Tosoni, C ;
Parisi, L .
JOURNAL OF GLAUCOMA, 2006, 15 (03) :213-217
[6]   Surveillance for ocular hypertension: an evidence synthesis and economic evaluation [J].
Burr, J. M. ;
Botello-Pinzon, P. ;
Takwoingi, Y. ;
Hernandez, R. ;
Vazquez-Montes, M. ;
Elders, A. ;
Asaoka, R. ;
Banister, K. ;
van der Schoot, J. ;
Fraser, C. ;
King, A. ;
Lemij, H. ;
Sanders, R. ;
Vernon, S. ;
Tuulonen, A. ;
Kotecha, A. ;
Glasziou, P. ;
Garway-Heath, D. ;
Crabb, D. ;
Vale, L. ;
Azuara-Blanco, A. ;
Perera, R. ;
Ryan, M. ;
Deeks, J. ;
Cook, J. .
HEALTH TECHNOLOGY ASSESSMENT, 2012, 16 (29) :1-+
[7]   Clinical evaluation of rebound tonometer [J].
Davies, LN ;
Bartlett, H ;
Mallen, EAH ;
Wolffsohn, JS .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (02) :206-209
[8]  
De Moraes CGV, 2011, ARCH OPHTHALMOL-CHIC, V129, P562, DOI 10.1001/archophthalmol.2011.72
[9]   Short- and Long-Term Phasing of Intraocular Pressure in Stable and Progressive Glaucoma [J].
Fogagnolo, Paolo ;
Orzalesi, Nicola ;
Centofanti, Marco ;
Oddone, Francesco ;
Manni, Gianluca ;
Rossetti, Luca .
OPHTHALMOLOGICA, 2013, 230 (02) :87-92
[10]   Latanoprost for open-angle glaucoma (UKGTS): a randomised, multicentre, placebo-controlled trial [J].
Garway-Heath, David F. ;
Crabb, David P. ;
Bunce, Catey ;
Lascaratos, Gerassimos ;
Amalfitano, Francesca ;
Anand, Nitin ;
Azuara-Blanco, Augusto ;
Bourne, Rupert R. ;
Broadway, David C. ;
Cunliffe, Ian A. ;
Diamond, Jeremy P. ;
Fraser, Scott G. ;
Ho, Tuan A. ;
Martin, Keith R. ;
McNaught, Andrew I. ;
Negi, Anil ;
Patel, Krishna ;
Russell, Richard A. ;
Shah, Ameet ;
Spry, Paul G. ;
Suzuki, Katsuyoshi ;
White, Edward T. ;
Wormald, Richard P. ;
Xing, Wen ;
Zeyen, Thierry G. .
LANCET, 2015, 385 (9975) :1295-1304