Determination of the carbon and hydrogen contents of gasoline using a combustion method and the estimation of their measurement uncertainty

被引:3
作者
Lim, Wan-Gyu [1 ,2 ]
Lee, Sang-Sup [2 ]
Ha, Jong-Han [1 ]
机构
[1] Kpetro, Res Inst Petr Technol, Cheongju 363883, South Korea
[2] Chungbuk Natl Univ, Dept Environm Engn, Cheongju 361763, South Korea
关键词
Gasoline; Carbon content; Hydrogen content; Combustion method; Uncertainty; NITROGEN;
D O I
10.1016/j.measurement.2015.06.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An analytical method of determining the carbon and hydrogen contents of gasoline was studied using a combustion method. Four pure organic hydrocarbons were selected and tested as calibration standards. Three hydrocarbon reagents, n-hexane, n-heptane, and isooctane, were found to be appropriate calibration standards. Two different calibration methods -one-point and four-point -were used to calibrate the analysis instrument and both methods showed satisfactory results. The measured carbon and hydrogen values were normalized to 100% minus the oxygen content and these values were more precise than the measured ones. The present paper also presents an evaluation of the measurement uncertainty. The uncertainty estimate for the four-point calibration was larger than that for the one-point calibration. The analysis of the contributions of the uncertainty sources showed that the purity of the calibration standard and the injected volume had a large effect on the overall uncertainty. The other parameters had virtually no influence. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 21 条
  • [1] [Anonymous], 2009, D24009 ASTM INT
  • [2] [Anonymous], 2012, D462912 ASTM INT
  • [3] Validation of a method for composition measurement of a non-standard liquid fuel for Emission Factor evaluation
    D'Emilia, Giulio
    Lucci, Simona
    Natale, Emanuela
    Pizzicannella, Francesca
    [J]. MEASUREMENT, 2011, 44 (01) : 18 - 23
  • [4] Measurement uncertainty from validation and duplicate analysis results in HPLC analysis of multivitamin preparations and nutrients with different galenic forms
    De Beer, JO
    Baten, P
    Nsengyumva, C
    Smeyers-Verbeke, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 767 - 811
  • [5] Eggleston H.S., 2006, IPCC Guidelines for national greenhouse gas inventories, Volume 2, Energy, Prepared by the National Greenhouse Gas Inventories Programme, V2
  • [6] Ellison S.L.R., 2000, Eurachem/ Citac Guide- Quantification uncertainty in analytical measurement
  • [7] A comparative uncertainty study of the purity assessment of chemical reference substances using differential scanning calorimetry (DSC) and mass balance method
    Gao, Jia-Min
    Ding, Li-Xia
    Hu, Chang-Qin
    [J]. THERMOCHIMICA ACTA, 2011, 525 (1-2) : 1 - 8
  • [8] Hochhauser AM, 1993, 930138 SAE
  • [9] ISO, 2008, GUID EXPR UNC MEAS
  • [10] Determination of the Carbon, Hydrogen and Nitrogen Contents of Alanine and Their Uncertainties Using the Certified Reference Material L-Alanine (NMIJ CRM 6011-a)
    Itoh, Nobuyasu
    Sato, Ayako
    Yamazaki, Taichi
    Numata, Masahiko
    Takatsu, Akiko