A STUDY ON PENETRATION DEPTH OF POLARIZATION IMAGING

被引:1
作者
Liao, Ran [1 ]
Zeng, Nan [1 ]
Li, Dongzhi [1 ,2 ]
Yun, Tianliang [1 ,2 ]
He, Yonghong [1 ]
Ma, Hui [1 ,2 ]
机构
[1] Tsinghua Univ, Grad Sch Shenzhen, Lab Opt Imaging & Sensing, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Phys, Key Lab Mol & Nanosci Educ Minist, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Polarization imaging; penetration depth; optical scattering;
D O I
10.1142/S1793545810000988
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical clearing improves the penetration depth of optical measurements in turbid tissues. Polarization imaging has been demonstrated as a potentially promising tool for detecting cancers in superficial tissues, but its limited depth of detection is a major obstacle to the effective application in clinical diagnosis. In the present paper, detection depths of two polarization imaging methods, i.e., rotating linear polarization imaging (RLPI) and degree of polarization imaging (DOPI), are examined quantitatively using both experiments and Monte Carlo simulations. The results show that the contrast curves of RLPI and DOPI are different. The characteristic depth of DOPI scales with transport mean free path length, and that of RLPI increases slightly with g. Both characteristic depths of RLPI and DOPI are on the order of transport mean free path length and the former is almost twice as large as the latter. It is expected that they should have different response to optical clearing process in tissues.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 50 条
  • [1] Study on the Penetration Depth of Light into Wheat Flour by Hyperspectral Imaging
    Wang, Xiaobin
    JOURNAL OF BIOBASED MATERIALS AND BIOENERGY, 2021, 15 (04) : 514 - 520
  • [2] Study of the Penetration Depth of an Anchor in the Dropping Anchor Process
    Liu R.
    Wang J.
    Bie S.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2020, 53 (05): : 508 - 516
  • [3] Continuous penetration depth
    Zhang, Xinyu
    Kim, Young J.
    Manocha, Dinesh
    COMPUTER-AIDED DESIGN, 2014, 46 : 3 - 13
  • [4] Exploring the Interplay of Wavelength, Quantum Yield, and Penetration Depth in In Vivo Fluorescence Imaging
    Harel, Meital
    Ankri, Rinat
    JOURNAL OF FLUORESCENCE, 2024,
  • [5] NUMERICAL STUDY OF MAGNETIC PENETRATION DEPTH IN MgB2
    Li, Bo
    Lin, De-Hua
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2013, 27 (15):
  • [6] Study of Penetration Depth Characteristics of Coherent Jet in EAF Steelmaking
    Liu F.-H.
    Wei G.-S.
    Zhu R.
    Tang T.-P.
    Chang J.
    Su R.-F.
    Liu R.-Z.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2018, 40 : 130 - 137
  • [7] Study of β- radiation penetration depth in low density organic liquids
    Kavitha, Y. B.
    Udagani, Chikkappa
    Kavitha, K. H.
    Kavya, G.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (08) : 656 - 659
  • [8] Penetration Depth Measurement of Near-Infrared Hyperspectral Imaging Light for Milk Powder
    Huang, Min
    Kim, Moon S.
    Chao, Kuanglin
    Qin, Jianwei
    Mo, Changyeun
    Esquerre, Carlos
    Delwiche, Stephen
    Zhu, Qibing
    SENSORS, 2016, 16 (04):
  • [9] Generalized penetration depth computation
    Zhang, Liangjun
    Kim, Young J.
    Varadhan, Gokul
    Manocha, Dinesh
    COMPUTER-AIDED DESIGN, 2007, 39 (08) : 625 - 638
  • [10] Penetration Depth of Edge Magnetoplasmons
    M. I. Goksu
    A. J. Dahm
    Journal of Low Temperature Physics, 2004, 134 : 553 - 558