Comparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial

被引:24
作者
Nayak, B. K. [1 ]
Jain, Elesh Kumar
机构
[1] Hinduja Natl Hosp, Dept Ophthalmol, Bombay 400016, Maharashtra, India
关键词
Anterior chamber maintainer; balanced salt solution plus; corneal endothelium; ophthalmic viscosurgical device; pachymetry; phacoemulsification; INTRAOCULAR IRRIGATING SOLUTIONS; CATARACT-SURGERY; LENS IMPLANTATION; MAINTAINER; EXTRACTION; PRESSURE; DAMAGE;
D O I
10.4103/0301-4738.45500
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: We conducted this study to evaluate and compare corneal endothelial cell loss between phacoemulsification with continuous anterior chamber infusion using anterior chamber maintainer (ACM) and phacoemulsification using ophthalmic viscosurgical device (OVD). Materials and Methods: This was a prospective, randomized controlled trial. Fifty eyes of 47 patients of senile cataract undergoing phacoemulsification were included. Patients were randomly allocated into two groups of 25 eyes each. Cataract surgery was performed by phacoemulsification with anterior chamber (AC) continuous infusion with balanced salt solution (BSS) plus and ACM without OVD in Group A, and in Group B, phacoemulsification was performed using OVD with BSS plus. Corneal endothelial cell count and pachymetry were performed preoperatively and postoperatively on day 1, day 7, and day 30. Results: The mean increase in pachymetry was 4.86, 2.94, and 1.94, (Group A) and 5.95, 3.94, and 0.51, (Group B) on first, seventh, and 30 (th) postoperative day respectively. The difference between the percentage increase in pachymetry between the two groups was not significant at day 1 ( P = 0.441), day 7 ( P = 0.298), and day 30 ( P=0.174) postoperatively. The density of endothelial cells decreased postoperatively (day 30) by 7.38 (Group A) and 7.47 (Group B) without any significant statistical difference ( P = 0.983) between two groups. Conclusion: Use of ACM for continuous AC infusion and omission of OVD during phacoemulsification did not cause significant difference in corneal swelling or endothelial cell loss in the immediate postoperative period up to one month.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 25 条
[1]  
ARAIE M, 1988, INVEST OPHTH VIS SCI, V29, P1884
[2]   PROTECTIVE PROPERTIES OF VISCOELASTIC SUBSTANCES (SODIUM HYALURONATE AND 2-PERCENT HYDROXYMETHYLCELLULOSE) AGAINST EXPERIMENTAL FREE-RADICAL DAMAGE TO THE CORNEAL ENDOTHELIUM [J].
ARTOLA, A ;
ALIO, JL ;
BELLOT, JL ;
RUIZ, JM .
CORNEA, 1993, 12 (02) :109-114
[3]   CORNEAL ENDOTHELIAL DAMAGE ASSOCIATED WITH PHACOEMULSIFICATION [J].
BINDER, PS ;
STERNBERG, H ;
WICKHAM, MG ;
WORTHEN, DM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 82 (01) :48-54
[4]   USING AN ANTERIOR-CHAMBER MAINTAINER TO CONTROL INTRAOCULAR-PRESSURE DURING PHACOEMULSIFICATION [J].
BLUMENTHAL, M ;
ASSIA, EI ;
CHEN, V ;
AVNI, I .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01) :93-96
[5]   Use of the anterior chamber maintainer in anterior segment surgery [J].
Chawla, HB ;
Adams, AD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02) :172-177
[6]  
CHENG H, 1986, ARCH OPHTHALMOL-CHIC, V104, P1170
[7]  
Domingues Flavia Guedes Pinto, 2005, Arq. Bras. Oftalmol., V68, P109, DOI 10.1590/S0004-27492005000100020
[8]  
EDELHAUSER JM, 1996, EUR J OPHTHALMOL, V6, P242
[9]   Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery [J].
Floyd, Michael ;
Valentine, Jeremy ;
Coombs, Jamie ;
Olson, Randall J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07) :1222-1226
[10]   EFFECTS OF INTRAOCULAR IRRIGATING SOLUTIONS ON THE CORNEAL ENDOTHELIUM AFTER INVIVO ANTERIOR-CHAMBER IRRIGATION [J].
GLASSER, DB ;
MATSUDA, M ;
ELLIS, JG ;
EDELHAUSER, HF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 99 (03) :321-328