A qualitative review for wireless health monitoring system

被引:0
作者
Arshad, Atika [1 ]
Ismail, Ahmad Fadzil [1 ]
Khan, Sheroz [1 ]
Alam, A. H. M. Zahirul [1 ]
Tasnim, Rumana [1 ]
Haider, Syed Samnan [1 ]
Shobaki, Mohammed M. [1 ]
Shahid, Zeeshan [1 ]
机构
[1] Int Islamic Univ, Dept Elect & Comp Engn, Kuala Lumpur 53100, Malaysia
来源
5TH INTERNATIONAL CONFERENCE ON MECHATRONICS (ICOM'13) | 2013年 / 53卷
关键词
D O I
10.1088/1757-899X/53/1/012030
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A proliferating interest has been being observed over the past years in accurate wireless system development in order to monitor incessant human activities in health care centres. Furthermore because of the swelling number of elderly population and the inadequate number of competent staffs for nursing homes there is a big market petition for health care monitoring system. In order to detect human researchers developed different methods namely which include Field Identification technique, Visual Sensor Network, radar detection, e-mobile techniques and so on. An all-encompassing overview of the non-wired human detection application advancement is presented in this paper. Inductive links are used for human detection application while wiring an electronic system has become impractical in recent times. Keeping in mind the shortcomings, an Inductive Intelligent Sensor (IIS) has been proposed as a novel human monitoring system for future implementation. The proposed sensor works towards exploring the signature signals of human body movement and size. This proposed sensor is fundamentally based on inductive loop that senses the presence and a passing human resulting an inductive change.
引用
收藏
页数:6
相关论文
共 15 条
[1]   A Multiple Inductive Loop Vehicle Detection System for Heterogeneous and Lane-Less Traffic [J].
Ali, S. Sheik Mohammed ;
George, Boby ;
Vanajakshi, Lelitha ;
Venkatraman, Jayashankar .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (05) :1353-1360
[2]  
[Anonymous], 2008, TRENDS AGED CARE SER
[3]  
Belshaw M, 2011, IEEE ENG MED BIO, P1773, DOI 10.1109/IEMBS.2011.6090506
[4]   Characterization of Component Under DC Biasing Condition Using an Inductive Coupling Approach [J].
Chang, Weng-Yew ;
See, Kye-Yak ;
Hu, Bo .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (08) :2109-2114
[5]  
[DESA United Nations Population Division], WORLD POP AG 1950 20
[6]  
Elsayed M., 2012, IEEE INT C E HLTH NE, p240
[7]   A Combined Inductive-Capacitive Proximity Sensor for Seat Occupancy Detection [J].
George, Boby ;
Zangl, Hubert ;
Bretterklieber, Thomas ;
Brasseur, Georg .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (05) :1463-1470
[8]  
Laditka J N, 2001, J Health Soc Policy, V13, P75, DOI 10.1300/J045v13n04_05
[9]   A Low-Power Bidirectional Telemetry Device With a Near-Field Charging Feature for a Cardiac Microstimulator [J].
Lee, Shuenn-Yuh ;
Cheng, Chih-Jen ;
Liang, Ming-Chun .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (04) :357-367
[10]  
Maurer U, 2006, BSN 2006: INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P142