Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator

被引:28
作者
Alem-Bezoubiri, A. [1 ]
Bezoubiri, F. [1 ]
Badreddine, A. [1 ]
Mazrou, H. [1 ]
Lounis-Mokrani, Z. [1 ]
机构
[1] CRNA, Div Phys Radiol, Algiers 16000, Algeria
关键词
Ambient equivalent; Neutron fluence; Energy spectra; Monte Carlo; Photoneutron; DYNAMIC MLC IMRT; NEUTRON-SPECTRA; ELECTRON; FIELD; SIMULATION; IRRADIATOR; TISSUE;
D O I
10.1016/j.radphyschem.2013.07.013
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A fully detailed Monte Carlo geometrical model of an 18 MV Varian Clinac 2100C medical linear accelerator, lodged at Blida Anti-Cancer Centre in Algeria, was developed during this study to estimate the photoneutrons spectra and doses at the patient table in a radiotherapy treatment room, for radiation protection purposes. Subsequently, thanks to this model, extensive M.C. calculations of neutron fluences and ambient dose equivalent were carried out at three selected locations on the patient table in the medical facility for a reference field size of 10 x 10 cm(2) and a Source to Surface Distance (SDD) of 100 cm. At the patient table, the calculated neutron ambient doses equivalent were 3.50, 0.89 and 0.62 mSv Gy(-1) at isocenter, 40 cm and 100 cm from the isocenter. Thereafter, a sensitivity analysis was performed to investigate the effect of variation of some pertinent parameters (source term model, Multi-Leaf Collimators and the shielding walls of the treatment room) on the production of the photoneutrons doses at the patient table. Finally, a full comparative study has been performed, in order, to estimate the consistency of the author's results. Therefore, the obtained M.C. results were compared, firstly, to a few measurements acquired, for the same irradiation facility using CR-39 Nuclear Track Detectors (NTDs), at the isocenter assuming different field sizes, and secondly, to both theoretical and experimental results available in the literature for the same medical facility and for different irradiation conditions. From these comparisons, a mean difference (for all the locations and field sizes considered) of about 15% was found. Despite, the possible differences in the accelerator modeling, including variations in the accelerator head and room geometries and differences in the computational tools and photoneutrons cross-sections data used in the literature, the results obtained through this investigation are encouraging, highlighting thereby the consistency of the geometrical M.C. model assumed in this work. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:381 / 392
页数:12
相关论文
共 41 条
[1]   Photoneutron intensity variation with field size around radiotherapy linear accelerator 18-MeV X-ray beam [J].
Al-Ghamdi, H. ;
Fazal-ur-Rehman ;
Al-Jarallah, M. I. ;
Maalej, N. .
RADIATION MEASUREMENTS, 2008, 43 (SUPPL.1) :S495-S499
[2]  
[Anonymous], LAUR031987 LOS AL NA
[3]  
[Anonymous], 2005, NCRP 151, National Council on Radiation Protection and Measurements
[4]   Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation [J].
Bednarz, Bryan ;
Xu, X. George .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04) :N43-N57
[5]   Monte Carlo simulation of scattered and thermal photoneutron fluences inside a radiotherapy room [J].
Facure, A. ;
Da Silva, A. X. ;
Falcao, R. C. .
RADIATION PROTECTION DOSIMETRY, 2007, 123 (01) :56-61
[6]   A study of neutron spectra from medical linear accelerators [J].
Facure, A ;
Falcao, RC ;
Silva, AX ;
Crispim, VR ;
Vitorelli, JC .
APPLIED RADIATION AND ISOTOPES, 2005, 62 (01) :69-72
[7]  
Followill David S, 2003, J Appl Clin Med Phys, V4, P189, DOI 10.1120/1.1571671
[8]   The evaluation of neutron and gamma ray dose equivalent distributions in patients and the effectiveness of shield materials for high energy photons radiotherapy facilities [J].
Ghassoun, J. ;
Senhou, N. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (04) :620-624
[9]   PHOTONEUTRONS FROM MEDICAL LINEAR ACCELERATORS - RADIOBIOLOGICAL MEASUREMENTS AND RISK ESTIMATES [J].
HALL, EJ ;
MARTIN, SG ;
AMOLS, H ;
HEI, TK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (01) :225-230
[10]   Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies [J].
Howell, RM ;
Hertel, NE ;
Wang, ZL ;
Hutchinson, J ;
Fullerton, GD .
MEDICAL PHYSICS, 2006, 33 (02) :360-368