A rapid LC-MS/MS method for determination of urinary EtG and application to a cut-off limit study

被引:1
|
作者
Anilanmert, Beril [1 ]
Ozdemir, Ali Acar [3 ]
Aydin, Muhammet [2 ]
Akgul, Meral [4 ]
Cengiz, Salih [1 ]
机构
[1] Istanbul Univ, Fac Med, Inst Forens Sci, TR-34303 Cerrahpasa, Turkey
[2] Istanbul Univ, Fac Med, Dept Microbiol, TR-34303 Cerrahpasa, Turkey
[3] World Med Pharmaceut Co, TR-34212 Gunesli Istanbul, Turkey
[4] Bagcilar 6th Family Healthcare Ctr, TR-34203 Bagcilar, Turkey
关键词
ethyl glucuronide; LC-MS/MS; rapid determination in urine; validation; cut-off limit; alcohol metabolite; TANDEM MASS-SPECTROMETRY; ETHYL-GLUCURONIDE; ALCOHOL-CONSUMPTION; FORENSIC GUIDELINES; VALIDATED METHOD; SULFATE; ETHANOL; QUANTIFICATION; ETHYLGLUCURONIDE; SAMPLES;
D O I
10.1515/chempap-2015-0173
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ethyl glucuronide (EtG) is a metabolite and a specific marker of alcohol consumption that can be detected days after the complete elimination of alcohol after drinking. A rapid, simple, and sensitive LC-ESI-MS/MS method for the determination of urinary ethyl glucuronide was developed and fully validated in accordance with analytical standards, using the C-18 column. The whole process including sample preparation and LC-MS/MS lasted 10 min. A comprehensive validation including HorRat, measurement uncertainty, system suitability and intermediate precision calculations among analysts, and a cut-off limit study was performed. The method was applied to real samples and a cutoff limit determination study. The LOD and LOQ (using the IUPAC and Eurachem methods) were determined as 104.21 ng mL(-1) and 165.00 ng mL(-1). A cut-off limit of approximate to 818 ng mg(-1) (normalised to creatinine) was found for urinary EtG. The results showed that the cut-off limits currently in use should be re-considered in further studies and standardised on a global scale. Normalisation to creatinine is important because of the risk of the dilution of urine intentionally or with a change of diet. The concentrations of real samples from subjects who had consumed alcohol were successfully predicted using this method, after zero HS-GC/MS results of urine alcohol concentration. (C) 2015 Institute of Chemistry, Slovak Academy of Sciences
引用
收藏
页码:1532 / 1540
页数:9
相关论文
共 50 条
  • [41] Biological Monitoring Method for Urinary Neonicotinoid Insecticides Using LC-MS/MS and Its Application to Japanese Adults
    Ueyama, Jun
    Nomura, Hiroshi
    Kondo, Takaaki
    Saito, Isao
    Ito, Yuki
    Osaka, Aya
    Kamijima, Michihiro
    JOURNAL OF OCCUPATIONAL HEALTH, 2014, 56 (06) : 461 - 468
  • [42] A New and Rapid LC-MS/MS Method for the Determination of Cysteamine Plasma Levels in Cystinosis Patients
    Simeoli, Raffaele
    Cairoli, Sara
    Greco, Marcella
    Bellomo, Francesco
    Mancini, Alessandro
    Rossi, Chiara
    Vici, Carlo Dionisi
    Emma, Francesco
    Goffredo, Bianca Maria
    PHARMACEUTICALS, 2024, 17 (05)
  • [43] Fast and sensitive LC-MS/MS method for the simultaneous determination of lisinopril and hydrochlorothiazide in human plasma
    Shah, Jaivik V.
    Shah, Priyanka A.
    Shah, Priya V.
    Sanyal, Mallika
    Shrivastav, Pranav S.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (03) : 163 - 169
  • [44] Multiresidue automated turbulent flow online LC-MS/MS method for the determination of antibiotics in milk
    Bousova, Katerina
    Senyuva, Hamide
    Mittendorf, Klaus
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (12): : 1901 - 1912
  • [45] Development of LC-MS/MS confirmatory method for the determination of testosterone in bovine serum
    Wozniak, Barbara
    Matraszek-Zuchowska, Iwona
    Witek, Sebastian
    Posyniak, Andrzej
    JOURNAL OF VETERINARY RESEARCH, 2017, 61 (01) : 81 - 89
  • [46] A multidrug LC-MS/MS method for the determination of five immunosuppressants in oral fluid
    Paniagua-Gonzalez, Lucia
    Lendoiro, Elena
    Otero-Anton, Esteban
    Molina-Perez, Esther
    Varo-Perez, Evaristo
    Lopez-Rivadulla, Manuel
    Cruz, Angelines
    de-Castro-Rios, Ana
    BIOANALYSIS, 2019, 11 (16) : 1509 - 1522
  • [47] Development and validation of a simple, rapid and sensitive LC-MS/MS method for the measurement of urinary neurotransmitters and their metabolites
    Yan, Jingya
    Kuzhiumparambil, Unnikrishnan
    Bandodkar, Sushil
    Solowij, Nadia
    Fu, Shanlin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (30) : 7191 - 7199
  • [48] Quantitation of tadalafil in human plasma using a sensitive and rapid LC-MS/MS method for a bioequivalence study
    Bhadoriya, Abhaysingh
    Dasandi, Bhavesh
    Parmar, Dharmesh
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2018, 8 (04) : 271 - 276
  • [49] Sensitive LC-MS/MS-ESI method for simultaneous determination of montelukast and fexofenadine in human plasma: application to a bioequivalence study
    Muppavarapu, Rajendraprasad
    Guttikar, Swati
    Rajappan, Manavalan
    Kamarajan, Kannan
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (08) : 1048 - 1056
  • [50] Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study
    Bhaumik, Uttam
    Ghosh, Animesh
    Sarkar, Amlan Kanti
    Bose, Anirbandeep
    Selvan, P. Senthamil
    Sengupta, Pinaki
    Chakraborty, Way Sankar
    Ghosh, Debotri
    Pal, Tapan Kumar
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1404 - 1410