Chimney stoves modestly improved Indoor Air Quality measurements compared with traditional open fire stoves: results from a small-scale intervention study in rural Peru

被引:46
作者
Hartinger, S. M. [1 ,2 ,3 ]
Commodore, A. A. [4 ]
Hattendorf, J. [2 ,3 ]
Lanata, C. F. [1 ,5 ]
Gil, A. I. [1 ]
Verastegui, H. [1 ]
Aguilar-Villalobos, M. [6 ]
Maeusezahl, D. [2 ,3 ]
Naeher, L. P. [4 ]
机构
[1] Inst Invest Nutr, Lima, Peru
[2] Swiss Trop & Publ Hlth Inst, Basel, Switzerland
[3] Univ Basel, Dept Epidemiol & Publ Hlth, Basel, Switzerland
[4] Univ Georgia, Dept Environm Hlth Sci, Athens, GA 30602 USA
[5] Univ Peruana Ciencias Aplicadas, Escuela Med, Lima, Peru
[6] Asociac Aire Ambiental, Lima, Peru
关键词
Household air pollution; Carbon monoxide; Particulate matter; Improved chimney stoves; Peru; RANDOMIZED-CONTROLLED-TRIAL; BIOMASS FUEL; POLLUTION; EXPOSURE; SMOKE; GUATEMALA; MORBIDITY; WOMEN;
D O I
10.1111/ina.12027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nearly half of the world's population depends on biomass fuels to meet domestic energy needs, producing high levels of pollutants responsible for substantial morbidity and mortality. We compare carbon monoxide (CO) and particulate matter (PM2.5) exposures and kitchen concentrations in households with study-promoted intervention (OPTIMA-improved stoves and control stoves) in San Marcos Province, Cajamarca Region, Peru. We determined 48-h indoor air concentration levels of CO and PM2.5 in 93 kitchen environments and personal exposure, after OPTIMA-improved stoves had been installed for an average of 7 months. PM2.5 and CO measurements did not differ significantly between OPTIMA-improved stoves and control stoves. Although not statistically significant, a post hoc stratification of OPTIMA-improved stoves by level of performance revealed mean PM2.5 and CO levels of fully functional OPTIMA-improved stoves were 28% lower (n = 20, PM2.5, 136 mu g/m(3) 95% CI 54-217) and 45% lower (n = 25, CO, 3.2 ppm, 95% CI 1.5-4.9) in the kitchen environment compared with the control stoves (n = 34, PM2.5, 189 mu g/m(3), 95% CI 116-261; n = 44, CO, 5.8 ppm, 95% CI 3.3-8.2). Likewise, although not statistically significant, personal exposures for OPTIMA-improved stoves were 43% and 17% lower for PM2.5 (n = 23) and CO (n = 25), respectively. Stove maintenance and functionality level are factors worthy of consideration for future evaluations of stove interventions.
引用
收藏
页码:342 / 352
页数:11
相关论文
共 36 条
[1]  
[Anonymous], 454R02006 USEPA OFF
[2]  
[Anonymous], NAT AMB AIR QUAL STA
[3]  
[Anonymous], GLOB ALL CLEAN COOKS
[4]  
[Anonymous], FACTS REPORTS
[5]   Indoor particle size distributions in homes with open fires and improved Patsari cook stoves [J].
Armendariz-Arnez, Cynthia ;
Edwards, Rufus D. ;
Johnson, Michael ;
Rosas, Irma A. ;
Espinosa, F. ;
Masera, Omar R. .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (24) :2881-2886
[6]   Indoor Air Pollution and Blood Pressure in Adult Women Living in Rural China [J].
Baumgartner, Jill ;
Schauer, James J. ;
Ezzati, Majid ;
Lu, Lin ;
Cheng, Chun ;
Patz, Jonathan A. ;
Bautista, Leonelo E. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2011, 119 (10) :1390-1395
[7]   Peruvian Highlands, Fume-Free [J].
Bodereau, Pilar Nores .
SCIENCE, 2011, 334 (6053) :157-157
[8]   Impact of improved stoves, house construction and child location on levels of indoor air pollution exposure in young Guatemalan children [J].
Bruce, N ;
McCracken, J ;
Albalak, R ;
Schei, M ;
Smith, KR ;
Lopez, V ;
West, C .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2004, 14 (Suppl 1) :S26-S33
[9]   A rapid assessment randomized-controlled trial of improved cookstoves in rural Ghana [J].
Burwen, Jason ;
Levine, David I. .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2012, 16 (03) :328-338
[10]   Indoor air pollution, cookstove quality, and housing characteristics in two Honduran communities [J].
Clark, Maggie L. ;
Reynolds, Stephen J. ;
Burch, James B. ;
Conway, Stuart ;
Bachand, Annette M. ;
Peel, Jennifer L. .
ENVIRONMENTAL RESEARCH, 2010, 110 (01) :12-18