摘要
The operation and accumulation of liquid water within the cell structure of a polymer electrolyte membrane fuel cell (PEMFC) with a dead-ended anode is observed using neutron imaging. The measurements are performed on a single cell with 53 cm(2) active area, Nafion 111-IP membrane, and carbon cloth gas diffusion layer. Even though dry hydrogen is supplied to the anode via pressure regulation, accumulation of liquid water in the anode gas distribution channels was observed in most tested conditions. Moreover, the accumulation of liquid water in the anode channels is followed by a significant voltage drop. Anode purges and cathode surges are also used as a diagnostic tool for differentiating between anode and cathode water flooding. The rate of accumulation of liquid water, and its impact on the rate of cell voltage drop is shown for a range of temperature, current density, cathode inlet RH, and air stoichiometric conditions. Operating the fuel cell under dead-ended anode conditions offers the opportunity to observe water dynamics and measured cell voltage during large and repeatable transients. (C) 2008 The Electrochemical Society.
引用
收藏
页码:B1168 / B1178
页数:11
相关论文
共 42 条
[1]   Buildup of nitrogen in direct hydrogen polymer-electrolyte fuel cell stacks [J].
Ahluwalia, R. K. ;
Wang, X. .
JOURNAL OF POWER SOURCES, 2007, 171 (01) :63-71
[2]   A nonlinear observer design for fuel cell hydrogen estimation [J].
Arcak, M ;
Görgün, H ;
Pedersen, LM ;
Varigonda, S .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2004, 12 (01) :101-110
[3]  
Barbir F, 2005, SUSTAIN WORLD SER, P1
[4]   Neutron imaging technique for in situ measurement of water transport gradients within Nafion in polymer electrolyte fuel cells [J].
Bellows, RJ ;
Lin, MY ;
Arif, M ;
Thompson, AK ;
Jacobson, D .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (03) :1099-1103
[5]   Water management in PEM fuel cells [J].
Berg, P ;
Promislow, K ;
St Pierre, J ;
Stumper, J ;
Wetton, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (03) :A341-A353
[6]   Review and comparison of approaches to proton exchange membrane fuel cell modeling [J].
Cheddie, D ;
Munroe, N .
JOURNAL OF POWER SOURCES, 2005, 147 (1-2) :72-84
[7]   Water distribution measurement for a PEMFC through neutron radiography [J].
Chen, Yong-Song ;
Peng, Huei ;
Hussey, Daniel S. ;
Jacobson, David L. ;
tran, Doanh T. ;
Abdel-Baset, Tarek ;
Biernacki, Mark .
JOURNAL OF POWER SOURCES, 2007, 170 (02) :376-386
[8]  
Chuang PA, 2005, PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, P31
[9]   Mathematical model of the PEMFC [J].
Dannenberg, K ;
Ekdunge, P ;
Lindbergh, G .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2000, 30 (12) :1377-1387
[10]   Methods of scattering corrections for quantitative neutron radiography [J].
Hassanein, R ;
Lehmann, E ;
Vontobel, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) :353-360