Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia

被引:13
作者
Liu, Yongji [1 ]
Wang, Yan [2 ]
Wang, Zhaoqi [1 ]
Zuo, Tong [2 ]
机构
[1] Nankai Univ, Minist Educ, Key Lab Opt Informat Sci & Technol, Inst Modern Opt, Tianjin 300071, Peoples R China
[2] Tianjin Eye Hosp, Refract Surg Ctr, Tianjin, Peoples R China
基金
美国国家科学基金会;
关键词
corneal power; intraocular lens; measurement error; refractive surgery; INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; PHOTOREFRACTIVE KERATECTOMY; ASPHERICITY; PENTACAM; LASIK;
D O I
10.1111/j.1475-1313.2012.00921.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32, 355361. doi: 10.1111/j.1475-1313.2012.00921.x Abstract Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 1839 years). The radius of curvature of anterior and posterior corneal surface, Q-Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power Fg, back vertex power Fv, and keratometric power SimK, were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 +/- 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (-0.21 +/- 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 +/- 0.11 D. With the Q-value changing from -0.09 to -0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 +/- 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 +/- 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 +/- 0.40 D. With the Q-value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [41] Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks
    Koprowski, Robert
    Lanza, Michele
    Irregolare, Carlo
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [42] Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks
    Robert Koprowski
    Michele Lanza
    Carlo Irregolare
    BioMedical Engineering OnLine, 15
  • [43] Power calculation after laser refractive surgery
    Rosa, Nicola
    Capasso, Luigi
    Lanza, Michele
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) : 1653 - 1653
  • [44] Regional analysis of posterior corneal elevation after laser refractive surgeries for correction of myopia of different degrees
    Chen, Tong
    Li, Na
    Ge, Tian
    Lin, Yue
    Wu, Xiaohui
    Gao, Hua
    Liu, Mingna
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (06) : 824 - 830
  • [45] Corneal biomechanics after laser refractive surgery: Unmasking differences between techniques
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Martinez, Javier
    Tauste, Ana
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (03) : 390 - 398
  • [46] Comparison of intraocular lens power calculation methods after myopic laser refractive surgery without previous refractive surgery data
    Yang, Ruibo
    Yeh, Annie
    George, Michael R.
    Rahman, Maria
    Boerman, Helen
    Wang, Ming
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09) : 1327 - 1335
  • [47] Assessing the corneal power change after refractive surgery using Scheimpflug imaging
    Gyldenkerne, Anders
    Ivarsen, Anders
    Hjortdal, Jesper O.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (03) : 299 - 307
  • [48] Evaluation of Corneal Biomechanics After Excimer Laser Corneal Refractive Surgery in High Myopic Patients Using Dynamic Scheimpflug Technology
    Hashemi, Hassan
    Asgari, Soheila
    Mortazavi, Mahdi
    Ghaffari, Reza
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : 371 - 377
  • [49] Intraocular lens power calculation after corneal refractive surgery
    Kalyani, Sachin D.
    Kim, Alisa
    Ladas, John G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) : 357 - 362
  • [50] Longitudinal Evaluation of Posterior Corneal Elevation after Laser Refractive Surgery Using Swept-Source Optical Coherence Tomography
    Chan, Tommy C. Y.
    Liu, Dexter
    Yu, Marco
    Jhanji, Vishal
    OPHTHALMOLOGY, 2015, 122 (04) : 687 - 692