Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia

被引:13
作者
Liu, Yongji [1 ]
Wang, Yan [2 ]
Wang, Zhaoqi [1 ]
Zuo, Tong [2 ]
机构
[1] Nankai Univ, Minist Educ, Key Lab Opt Informat Sci & Technol, Inst Modern Opt, Tianjin 300071, Peoples R China
[2] Tianjin Eye Hosp, Refract Surg Ctr, Tianjin, Peoples R China
基金
美国国家科学基金会;
关键词
corneal power; intraocular lens; measurement error; refractive surgery; INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; PHOTOREFRACTIVE KERATECTOMY; ASPHERICITY; PENTACAM; LASIK;
D O I
10.1111/j.1475-1313.2012.00921.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32, 355361. doi: 10.1111/j.1475-1313.2012.00921.x Abstract Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 1839 years). The radius of curvature of anterior and posterior corneal surface, Q-Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power Fg, back vertex power Fv, and keratometric power SimK, were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 +/- 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (-0.21 +/- 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 +/- 0.11 D. With the Q-value changing from -0.09 to -0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 +/- 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 +/- 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 +/- 0.40 D. With the Q-value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [31] Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery
    Savini, Giacomo
    Calossi, Antonio
    Camellin, Massimo
    Carones, Francesco
    Fantozzi, Marco
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) : 1109 - 1115
  • [32] Intraocular lens power calculation after previous laser refractive surgery
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) : 759 - 765
  • [33] New Scheimpflug camera device in measuring corneal power changes after myopic laser refractive surgery
    Lanza, Michele
    Iaccarino, Stefania
    Cennamo, Michela
    Lanza, Alessandro
    Coen, Giovanni
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02) : 115 - 119
  • [34] Corneal power determination after previous corneal refractive surgery for intraocular lens calculation
    Stakheev, AA
    Balashevich, LJ
    CORNEA, 2003, 22 (03) : 214 - 220
  • [35] Accuracy of 12 Intraocular Lens Power Formulas After Corneal Myopic Refractive Surgery
    Rong, Xin
    Liu, Jiewei
    Jiang, Lin
    Wang, Xiaogang
    Feng, Tianfeng
    Lu, Zhenyang
    Fan, Zeqi
    Yan, Hua
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (06) : e354 - e361
  • [36] Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes
    Yanjun Hua
    Chao Pan
    Qinmei Wang
    International Ophthalmology, 2019, 39 : 2467 - 2475
  • [37] Computerized Scheimpflug densitometry as a measure of corneal optical density after excimer laser refractive surgery in myopic eyes
    Cennamo, Gilda
    Forte, Raimondo
    Aufiero, Bernardino
    La Rana, Agostino
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) : 1502 - 1506
  • [38] Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
    Michele Lanza
    Robert Koprowski
    Mario Bifani Sconocchia
    BioMedical Engineering OnLine, 17
  • [39] Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery
    Zhang, Jing
    He, Fanglin
    Liu, Yan
    Fan, Xianqun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (06)
  • [40] Evaluation of Different IOL Calculation Formulas of the ASCRS Calculator in Eyes After Corneal Refractive Laser Surgery for Myopia With Multifocal IOL Implantation
    Vrijman, Violette
    Abulafia, Adi
    van der Linden, Jan Willem
    van der Meulen, Ivanka J. E.
    Mourits, Maarten P.
    Lapid-Gortzak, Ruth
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (01) : 54 - 59