Agreement of Central Corneal Thickness Measurements between Scheimpflug Photography and Optical Low-Coherence Reflectometry in Children

被引:4
作者
Hashemi, Hassan [1 ]
Nabovati, Payam [2 ]
Khabazkhoob, Mehdi [3 ]
Emamian, Mohammad Hassan [4 ]
Yekta, Abbasali [5 ]
Fotouhi, Akbar [6 ]
机构
[1] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[2] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil Sci, Dept Optometry, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Tehran, Iran
[4] Shahroud Univ Med Sci, Ophthalm Epidemiol Res Ctr, Shahroud, Iran
[5] Mashhad Univ Med Sci, Refract Errors Res Ctr, Sch Paramed Sci, Mashhad, Razavi Khorasan, Iran
[6] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Corneal thickness; corneal imaging; agreement; children; Iran; ULTRASOUND PACHYMETRY; SPECULAR MICROSCOPY; PENTACAM; TOMOGRAPHY; LENSTAR; DEVICES;
D O I
10.1080/08820538.2020.1810288
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Central corneal thickness (CCT) is a key indicator of the corneal health status and is therefore of clinical importance. The aim of the present study was to determine the agreement between Scheimpflug photography (SP) and optical low-coherence reflectometry (OLCR) systems in measuring the CCT in children. Methods In this cross-sectional study, the samples were selected from Shahroud schoolchildren using cluster sampling. The samples then underwent optometric examinations, including the measurement of visual acuity and refraction. CCT measurements were done by the SP and OLCR systems between 8 am and 4 pm. To evaluate the agreement between these devices, 95% limits of agreement (LoA) and interclass correlation coefficient (ICC) were reported. Results After applying the exclusion criteria, 4890 right eyes (53.2% male) were analyzed. The mean age of the students was 9.22 +/- 1.72 years (range: 6-12 years). The mean CCT by the SP and OLCR systems was 555.30 +/- 34.15 and 550.23 +/- 35.11 mu m, respectively. The 95% LoA between the two devices was -19.81 to 9.66 mu m, and the ICC was 0.983. The CCT difference between the SP and OLCR systems was 5.61 mu m in boys and 3.36 mu m in girls. The CCT difference between the two devices was 6.41 mu m in 6-year-old and 3.54 mu m in 12-year-old children. The 95% LoA was -17.96 to 9.58 mu m and -18.89 to 8.47 mu m and the ICC was 0.987 and 0.984 in myopic and hyperopic subjects, respectively. Conclusion The results of this study showed a high agreement between OLCR and SP measurements of CCT in children.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [41] Pachymetric measurements with a new Scheimpflug photography-based system Intraobserver repeatability and agreement with optical coherence tomography pachymetry
    Milla, Myriam
    Pinero, David P.
    Amparo, Francisco
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 310 - 316
  • [42] Utility of the Swept Source Optical Coherence Tomography for Measurements of Central Corneal Thickness
    Kim, Im Gyu
    Lee, Chong Eun
    Lee, Jun Seok
    Seo, Sam
    Lee, Kyoo Won
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1542 - 1548
  • [43] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    İrfan Akalın
    Melek Tüfek
    Mustafa Türkyılmaz
    Faruk Öztürk
    International Ophthalmology, 2019, 39 : 1337 - 1343
  • [44] Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry
    Ladi, Jeevan S.
    Shah, Nitant A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (05) : 385 - 388
  • [45] Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: Keratometry and repeatability
    Mueller, Andreas
    Thomas, Bettina C.
    Auffarth, Gerd U.
    Holzer, Mike P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05) : 672 - 678
  • [46] Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
    Huang, Jinhai
    Savini, Giacomo
    Wang, Chengfang
    Lu, Weicong
    Gao, Rongrong
    Li, Yuanguang
    Wang, Qinmei
    Zhao, Yune
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [47] Measurement of the Central Corneal Thickness using Optical Reflectometry and Ultrasound
    Beutelspacher, S. C.
    Serbecic, N.
    Scheuerle, A. F.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (09) : 815 - 818
  • [48] Comparison of Oculus Pentacam and Stratus Optical Coherence Tomography for Measurement of Central Corneal Thickness
    Ceylan, Osman Melih
    Turk, Adem
    Erdurman, Cuneyt
    Mumcuoglu, Tarkan
    Erdem, Uzeyir
    Gokce, Gokcen
    Dagli, Selim
    CORNEA, 2011, 30 (06) : 670 - 674
  • [49] Normative values for optical coherence tomography parameters in healthy children and interexaminer agreement for choroidal thickness measurements
    Turan, Kadriye Erkan
    Sekeroglu, Hande Taylan
    Baytaroglu, Ata
    Bezci, Figen
    Karahan, Sevilay
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2018, 81 (01) : 1 - 6
  • [50] COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS BETWEEN OPTICAL AND ULTRASOUND PACHOMETERS
    GIASSON, C
    FORTHOMME, D