Agreement of Central Corneal Thickness Measurements between Scheimpflug Photography and Optical Low-Coherence Reflectometry in Children

被引:4
|
作者
Hashemi, Hassan [1 ]
Nabovati, Payam [2 ]
Khabazkhoob, Mehdi [3 ]
Emamian, Mohammad Hassan [4 ]
Yekta, Abbasali [5 ]
Fotouhi, Akbar [6 ]
机构
[1] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[2] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil Sci, Dept Optometry, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Tehran, Iran
[4] Shahroud Univ Med Sci, Ophthalm Epidemiol Res Ctr, Shahroud, Iran
[5] Mashhad Univ Med Sci, Refract Errors Res Ctr, Sch Paramed Sci, Mashhad, Razavi Khorasan, Iran
[6] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Corneal thickness; corneal imaging; agreement; children; Iran; ULTRASOUND PACHYMETRY; SPECULAR MICROSCOPY; PENTACAM; TOMOGRAPHY; LENSTAR; DEVICES;
D O I
10.1080/08820538.2020.1810288
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Central corneal thickness (CCT) is a key indicator of the corneal health status and is therefore of clinical importance. The aim of the present study was to determine the agreement between Scheimpflug photography (SP) and optical low-coherence reflectometry (OLCR) systems in measuring the CCT in children. Methods In this cross-sectional study, the samples were selected from Shahroud schoolchildren using cluster sampling. The samples then underwent optometric examinations, including the measurement of visual acuity and refraction. CCT measurements were done by the SP and OLCR systems between 8 am and 4 pm. To evaluate the agreement between these devices, 95% limits of agreement (LoA) and interclass correlation coefficient (ICC) were reported. Results After applying the exclusion criteria, 4890 right eyes (53.2% male) were analyzed. The mean age of the students was 9.22 +/- 1.72 years (range: 6-12 years). The mean CCT by the SP and OLCR systems was 555.30 +/- 34.15 and 550.23 +/- 35.11 mu m, respectively. The 95% LoA between the two devices was -19.81 to 9.66 mu m, and the ICC was 0.983. The CCT difference between the SP and OLCR systems was 5.61 mu m in boys and 3.36 mu m in girls. The CCT difference between the two devices was 6.41 mu m in 6-year-old and 3.54 mu m in 12-year-old children. The 95% LoA was -17.96 to 9.58 mu m and -18.89 to 8.47 mu m and the ICC was 0.987 and 0.984 in myopic and hyperopic subjects, respectively. Conclusion The results of this study showed a high agreement between OLCR and SP measurements of CCT in children.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [21] Reproducibility of the measurement of central corneal thickness in healthy subjects obtained with the optical low coherence reflectometry pachymeter and comparison with the ultrasonic pachymetry
    Garza-Leon, Manuel
    Plancarte-Lozano, Eduardo
    Del Valle-Penella, Agustin
    de Lourdes Guzman-Martinez, Maria
    Villarreal-Gonzalez, Andres
    CIRUGIA Y CIRUJANOS, 2018, 86 (01): : 44 - 49
  • [22] In vivo measurement of central corneal thickness in normal chicks (Gallus gallus domesticus) with the optical low-coherence reflectometer
    Tappeiner, Christoph
    Goldblum, David
    Katsoulis, Konstantinos
    Sarra, Gian-Marco
    Frueh, Beatrice E.
    VETERINARY OPHTHALMOLOGY, 2011, 14 (04) : 257 - 261
  • [23] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    Akalin, Irfan
    Tufek, Melek
    Turkyilmaz, Mustafa
    Ozturk, Faruk
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (06) : 1337 - 1343
  • [24] Reliability and agreement of the central and mid-peripheral corneal thickness measured by a new Scheimpflug based imaging
    Yu, A-Yong
    Ye, Junming
    Savini, Giacomo
    Wang, Yiran
    Zhang, Tianjiao
    Chen, Min
    Wang, Qinmei
    Huang, Jinhai
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (14)
  • [25] Comparison of a new Scheimpflug imaging combined with partial coherence interferometry biometer and a low-coherence reflectometry biometer
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (11) : 1406 - 1412
  • [26] Agreement and reliability in measuring central corneal thickness with a rotating Scheimpflug-Placido system and ultrasound pachymetry
    Maresca, Nunzio
    Zeri, Fabrizio
    Palumbo, Paolo
    Calossi, Antonio
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06) : 442 - 446
  • [27] Comparison of agreement and efficiency of a swept source-optical coherence tomography device and an optical low-coherence reflectometry device for biometry measurements during cataract evaluation
    Passi, Samuel F.
    Thompson, Atalie C.
    Gupta, Preeya K.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 2245 - 2251
  • [28] Comparison of preoperative angle kappa measurements in the eyes of cataract patients obtained from Pentacam Scheimpflug system, optical low-coherence reflectometry, and ray-tracing aberrometry
    Qin, Miaomiao
    Yuan, Yurong
    Wang, Ying
    Li, Pengfei
    Chen, Wei
    Wang, Yong
    Yang, Mei
    Wu, Jian
    Ji, Min
    Luo, Jiawei
    Tang, Jiamin
    Chen, Xiaojuan
    Huang, Yemeng
    Guan, Huaijin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [29] Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements
    Briggs, Stella
    Bin Moammar, Marwa
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (02) : 239 - 242
  • [30] Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera
    Ishibazawa, Akihiro
    Igarashi, Sho
    Hanada, Kazuomi
    Nagaoka, Taiji
    Ishiko, Satoshi
    Ito, Haruna
    Yoshida, Akitoshi
    CORNEA, 2011, 30 (06) : 615 - 619