Pulsed photoacoustic Doppler flowmetry using time-domain cross-correlation: Accuracy, resolution and scalability

被引:51
|
作者
Brunker, Joanna [1 ]
Beard, Paul [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
来源
基金
英国工程与自然科学研究理事会;
关键词
VIVO; SPECTROSCOPY; ULTRASOUND; FLOW;
D O I
10.1121/1.4739458
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The feasibility of making spatially resolved measurements of blood velocity using a pulsed photoacoustic Doppler technique in acoustic resolution mode has been investigated. Doppler time shifts were quantified via cross-correlation of photoacoustic waveform pairs generated within a blood-simulating phantom using pairs of light pulses. The phantom comprised micron-scale absorbers imprinted on an acetate sheet and moved at known velocities. The photoacoustic waves were detected using PZT ultrasound transducers operating at center frequencies of 20 MHz, 5 MHz and 3.5 MHz; measurements of velocity and resolution were calculated from the mean cross-correlation function of 25 waveform pairs. Velocities in the range +/- 0.15 to +/- 1.5 ms(-1) were quantified with accuracies as low as 1%. The transducer focal beam width determines a maximum measurable velocity vertical bar V-max vertical bar beyond which correlation is lost due to absorbers moving out of the focal beam between the two laser pulses. Below vertical bar V-max vertical bar a measurement resolution of <4% of the measured velocity was achieved. Resolution and vertical bar V-max vertical bar can be scaled to much lower velocities such as those encountered in microvasculature (<50 mms(-1)). The advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made, offering the prospect of mapping flow within the microcirculation. (C) 2012 Acoustical Society of America. [http://dx.doi.org/10.1121/1.4739458]
引用
收藏
页码:1780 / 1791
页数:12
相关论文
共 50 条
  • [1] Pulsed photoacoustic Doppler flowmetry using a cross-correlation method
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [2] Acoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [3] Assessment of cerebral autoregulation using time-domain cross-correlation analysis
    Chiu, CC
    Yeh, SJ
    COMPUTERS IN BIOLOGY AND MEDICINE, 2001, 31 (06) : 471 - 480
  • [4] VOLUME FLOW ESTIMATION USING TIME-DOMAIN CORRELATION AND ULTRASONIC FLOWMETRY
    FORSBERG, F
    LIU, JB
    RUSSELL, KM
    GUTHRIE, SL
    GOLDBERG, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (08): : 1037 - 1045
  • [5] IMPLEMENTATION OF ULTRASOUND TIME-DOMAIN CROSS-CORRELATION BLOOD VELOCITY ESTIMATORS
    JENSEN, JA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (05) : 468 - 474
  • [6] Time-Domain Far-Field Measurements for Cross-Correlation Analysis
    Kuznetsov, Y.
    Baev, A.
    Haider, M.
    Russer, J. A.
    Russer, P.
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1517 - 1520
  • [7] STATIONARY ECHO CANCELING IN VELOCITY ESTIMATION BY TIME-DOMAIN CROSS-CORRELATION
    JENSEN, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) : 471 - 477
  • [8] A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation
    Won, Joong-Sun
    KOREAN JOURNAL OF REMOTE SENSING, 2022, 38 (03) : 251 - 263
  • [9] TIME-DOMAIN ANALYSIS OF CROSS-CORRELATION FOR TIME-DELAY ESTIMATION WITH AN AUTOCORRELATED SIGNAL
    KUMAR, A
    BARSHALOM, Y
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1993, 41 (04) : 1664 - 1668
  • [10] Time-domain cross-correlation baroreflex sensitivity: performance on the EUROBAVAR data set
    Westerhof, BE
    Gisolf, J
    Stok, WJ
    Wesseling, KH
    Karemaker, JM
    JOURNAL OF HYPERTENSION, 2004, 22 (07) : 1371 - 1380