Pulsed photoacoustic Doppler flowmetry using time-domain cross-correlation: Accuracy, resolution and scalability

被引:51
|
作者
Brunker, Joanna [1 ]
Beard, Paul [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
VIVO; SPECTROSCOPY; ULTRASOUND; FLOW;
D O I
10.1121/1.4739458
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The feasibility of making spatially resolved measurements of blood velocity using a pulsed photoacoustic Doppler technique in acoustic resolution mode has been investigated. Doppler time shifts were quantified via cross-correlation of photoacoustic waveform pairs generated within a blood-simulating phantom using pairs of light pulses. The phantom comprised micron-scale absorbers imprinted on an acetate sheet and moved at known velocities. The photoacoustic waves were detected using PZT ultrasound transducers operating at center frequencies of 20 MHz, 5 MHz and 3.5 MHz; measurements of velocity and resolution were calculated from the mean cross-correlation function of 25 waveform pairs. Velocities in the range +/- 0.15 to +/- 1.5 ms(-1) were quantified with accuracies as low as 1%. The transducer focal beam width determines a maximum measurable velocity vertical bar V-max vertical bar beyond which correlation is lost due to absorbers moving out of the focal beam between the two laser pulses. Below vertical bar V-max vertical bar a measurement resolution of <4% of the measured velocity was achieved. Resolution and vertical bar V-max vertical bar can be scaled to much lower velocities such as those encountered in microvasculature (<50 mms(-1)). The advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made, offering the prospect of mapping flow within the microcirculation. (C) 2012 Acoustical Society of America. [http://dx.doi.org/10.1121/1.4739458]
引用
收藏
页码:1780 / 1791
页数:12
相关论文
共 10 条
  • [1] Pulsed photoacoustic Doppler flowmetry using a cross-correlation method
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [2] Acoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation
    Brunker, J.
    Beard, P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [3] Practical parameters for extending the velocity range when applying a partial inversion pulse to the ultrasonic time-domain cross-correlation method
    Wada, Sanehiro
    Furuichi, Noriyuki
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [4] Calibration-free in vivo transverse blood flowmetry based on cross correlation of slow time profiles from photoacoustic microscopy
    Zhou, Yong
    Liang, Jinyang
    Maslov, Konstantin I.
    Wang, Lihong V.
    OPTICS LETTERS, 2013, 38 (19) : 3882 - 3885
  • [5] Terahertz time-domain magneto-optics using pulsed magnetic fields
    Molter, Daniel
    Ellrich, Frank
    Weinland, Tristan
    George, Sylvie
    Goiran, Michel
    Keilmann, Fritz
    Beigang, Rene
    Leotin, Jean
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [6] Time delay estimation of random signals using cross-correlation with Hilbert Transform
    Hanus, Robert
    MEASUREMENT, 2019, 146 : 792 - 799
  • [7] Terahertz Time-Domain Magnetospectroscopy Using a Table-Top Repetitive Pulsed Magnet
    Noe, G. T.
    Zhang, Q.
    Lee, J.
    Kato, E.
    Nojiri, H.
    Woods, G. L.
    Kono, J.
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [8] Improving accuracy of pipe flow rate measurement with ultrasonic time-domain correlation method under small number density of reflectors
    Wada, Sanehiro
    Furuichi, Noriyuki
    MEASUREMENT, 2021, 179
  • [9] A terahertz time-domain super-resolution imaging method using a local-pixel graph neural network for biological products
    Lei, Tong
    Tobin, Brian
    Liu, Zihan
    Yang, Shu-Yi
    Sun, Da-Wen
    ANALYTICA CHIMICA ACTA, 2021, 1181 (1181)
  • [10] Optimization and extraction of functional information from in vitro flow models using dual-beam spectral-domain optical coherence tomography cross-correlation analysis
    Daly, Susan M.
    Silien, Christophe
    Leahy, Martin J.